Product Information

D4D225-CC01-02

D4D225-CC01-02 electronic component of ebm papst

Datasheet
Blowers & Centrifugal Fans AC Centrifugal Blower, 341mm, 230VAC

Manufacturer: ebm papst
Large
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 912.1173 ea
Line Total: USD 912.12

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between
Fri. 14 Jun to Thu. 04 Jul

MOQ : 1
Multiples : 1

Stock Image

D4D225-CC01-02
ebm papst

1 : USD 912.1173

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Type
Current Type
Operating Supply Voltage
Height
Depth
Series
IP Rating
Brand
Product Type
Factory Pack Quantity :
Subcategory
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 32

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 1

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 0

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
RER100-25/14 electronic component of ebm papst RER100-25/14

DC Motorized Impeller Centrifugal Ball Bearing 24V 12V to 28V 33.6CFM 47dB 100 X 32mm
Stock : 50

ODB600PT-12LB electronic component of Orion ODB600PT-12LB

Blowers & Centrifugal Fans DC Blower, Single Side Inlet, 120x31mm, 12VDC, 22CFM, 5.64W, 42dBA, 2300RPM, Dual Ball Bearing, 2x Wire Leads
Stock : 1

GB1205PKV1-8AY.GN electronic component of Sunon GB1205PKV1-8AY.GN

Blowers & Centrifugal Fans Blower, 50x20mm, 12VDC, 5.7CFM, 1.5W, 35dBA, Vapo Bearing, MagLev, Auto Restart
Stock : 1000

RL48-1914ML electronic component of ebm papst RL48-1914ML

Blowers & Centrifugal Fans DC Radial Blower, 76x76x27mm, 24VDC, 12.9CFM, 2.9W, 3500RPM, FlatPak Series
Stock : 0

04701.9-00 electronic component of Stego 04701.9-00

Heater; HGK 047; 20W; 120÷230V; IP44
Stock : 3

04710.0-00 electronic component of Stego 04710.0-00

Heater; HGK 047; 10W; 12÷30V; IP44
Stock : 1

06050.0-00 electronic component of Stego 06050.0-00

Heater; CSK 060; 30W; Uoper: 110÷265V; IP20; Urated: 120/240V
Stock : 9

06040.1-00 electronic component of Stego 06040.1-00

Heater; CSK 060; 10W; Uoper: 12÷30V; IP20; Urated: 24V
Stock : 1

04711.0-00 electronic component of Stego 04711.0-00

Heater; HGK 047; 20W; 12÷30V; IP44
Stock : 6

PHT050 electronic component of PLASTIM PHT050

Heater; 50W; 100÷250V; IP20; DIN rail; 138x70x59mm
Stock : 0

D4D225-CC01-02 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1@de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Electrical voltage 1 DANGER 1.5 Safety and protective functions 2 Indicates an imminently hazardous situation which, if not 1.6 Electromagnetic radiation 2 avoided, will result in death or serious injury. Compliance with 1.7 Mechanical movement 2 the measures is mandatory. 1.8 Emission 2 1.9 Hot surface 2 WARNING Indicates a potentially hazardous situation which, if not avoided, 1.10 Transport 2 could result in death or serious injury. Exercise extreme 1.11 Storage 2 caution while working. 2. PROPER USE 3 CAUTION Indicates a potentially hazardous situation which, if not avoided, 3. TECHNICAL DATA 4 may result in minor or moderate injury or damage of property. 3.1 Product drawing 4 3.2 Nominal data 5 NOTE 3.3 Data in accordance with ecodesign regulation EU 327/2011 5 A potentially harmful situation can occur and, if not avoided, can 3.4 Technical features 5 lead to property damage. 3.5 Mounting data 5 3.6 Transport and storage conditions 6 1.2 Staff qualification The device may only be transported, unpacked, installed, operated, 4. CONNECTION AND START-UP 6 maintained and otherwise used by qualified, trained and authorised 4.1 Connecting the mechanical system 6 technical staff. 4.2 Connecting the electrical system 6 Only authorised specialists are permitted to install the device, to carry 4.3 Connection of the cables 7 out a test run and to perform work on the electrical installation. 4.4 Connection screen 8 4.5 Checking the connections 9 1.3 Basic safety rules 4.6 Switch on device 9 4.7 Switching off the device 9 Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device. 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9 The local industrial safety regulations must always be observed when CAUSES AND REMEDIES working on the device. 5.1 Cleaning 10 Keep the workplace clean and tidy. Untidiness in the working area 5.2 Safety test 10 increases the risk of injury. 5.3 Disposal 10 Observe the following when working on the unit: ; Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 1.4 Electrical voltage ; Check the electrical equipment of the device at regular intervals, refer to chapter 5.2 Safety test. ; Replace loose connections and defective cables immediately. DANGER Electrical load on the device Risk of electric shock Stand on a rubber mat if you are working on an electrically charged device. Item no. 10889-5-9970 ENG Revision 202174 Release 2018-12-28 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsD4D225-CC01-02 Operating instructions WARNING 1.7 Mechanical movement Terminals and connections have voltage even with a DANGER unit that is shut off Rotating device Electric shock Body parts that come into contact with the rotor and impeller Wait five minutes after disconnecting the voltage at all poles can be injured. before opening the device. Secure the device against accidental contact. CAUTION Before working on the system/machine, wait until all In the event of failure, there is electric voltage at the parts have come to a standstill. rotor and impeller The rotor and impeller are base insulated. WARNING Rotating device Do not touch the rotor and impeller once they are installed. Long hair, dangling items of clothing, jewellery and similar items CAUTION can become entangled and be pulled into the device. Risk of The motor restarts automatically when operating voltage injury. is applied, e.g. after a power failure. Do not wear any loose-fitting or dangling clothing or jewellery Danger of injury while working on rotating parts. Keep out of the danger zone of the device. Protect long hair with a cap. When working on the device, switch off the mains supply voltage and secure the latter from being switched on 1.8 Emission again. WARNING Wait until the device stops. Depending on the installation and operating conditions, a sound pressure level greater than 70 dB(A) may arise. 1.5 Safety and protective functions Danger of noise-induced hearing loss DANGER Take appropriate technical safety measures. Protective device missing and protective device not Protect operating personnel with appropriate safety functioning equipment, e.g. hearing protection. Without a protective device there is a risk of serious injury, for Also observe the requirements of local agencies. instance when reaching into the device during operation. Operate the device only with a fixed protective device and 1.9 Hot surface guard grille. CAUTION The fixed protective device must be able to withstand the High temperature at the motor housing kinetic energy of a fan blade that becomes detached at Danger of burn injuries maximum speed. There must not be any gaps which it is possible to reach into with the fingers, for example. Ensure that sufficient protection against accidental contact is provided. The device is a built-in component. As the operator, you are responsible for ensuring that the device is secured 1.10 Transport adequately. Stop the device immediately if a protective device is NOTE found to be missing or ineffective. Transport of device Transport the device in its original packaging only. 1.6 Electromagnetic radiation Secure the device so that it does not slip, e.g. by using a Interference from electromagnetic radiation is possible, e.g. in conjunction clamping strap. with open and closed-loop control devices. If unacceptable emission intensities occur when the fan is installed, 1.11 Storage appropriate shielding measures have to be taken by the user. ; Store the device, partially or fully assembled, in the original NOTE packaging in a clean, dry and weatherproof place free of vibrations. Electrical or electromagnetic interferences after ; Protect the device against environmental effects and dirt until final integrating the device in installations on the customer's installation. side. ; We recommend storing the device for no longer than one year in Verify that the entire setup is EMC compliant. order to guarantee trouble-free operation and longest possible service life. ; Even devices explicitly intended for outdoor use are to be stored as described prior to commissioning. ; Maintain the storage temperature, see chapter 3.6 Transport and storage conditions. Item no. 10889-5-9970 ENG Revision 202174 Release 2018-12-28 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions

Tariff Desc

FANS AND/OR BLOWERS, DC OR AC, axial OR radial OR crossflow type, having ANY one OR more of the following:
(a) sleeve OR ball OR magnetic bearings;
(c) AC operating voltage NOT less than 115 V and NOT greater than 240 V;
(d) maximum speed exceeding 1 000 RPM;
(e) diameter NOT greater than 300 mm;
(f) height NOT greater than 300 mm;
(g) length NOT greater than 300 mm,
with OR without filters
TC 17129205
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted