Product Information

R1G220-AB35-65

R1G220-AB35-65 electronic component of ebm papst

Datasheet
DC BACKWARD-CURVED MOTORIZED IMPELLER

Manufacturer: ebm papst
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Availability Price Quantity
0 - WHS 1


Multiples : 10

Stock Image

R1G220-AB35-65
ebm papst

N/A

     
Manufacturer
Product Category
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 32

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 1

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 0

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
RER100-25/14 electronic component of ebm papst RER100-25/14

DC Motorized Impeller Centrifugal Ball Bearing 24V 12V to 28V 33.6CFM 47dB 100 X 32mm
Stock : 50

ODB600PT-12LB electronic component of Orion ODB600PT-12LB

Blowers & Centrifugal Fans DC Blower, Single Side Inlet, 120x31mm, 12VDC, 22CFM, 5.64W, 42dBA, 2300RPM, Dual Ball Bearing, 2x Wire Leads
Stock : 1

GB1205PKV1-8AY.GN electronic component of Sunon GB1205PKV1-8AY.GN

Blowers & Centrifugal Fans Blower, 50x20mm, 12VDC, 5.7CFM, 1.5W, 35dBA, Vapo Bearing, MagLev, Auto Restart
Stock : 1000

RL48-1914ML electronic component of ebm papst RL48-1914ML

Blowers & Centrifugal Fans DC Radial Blower, 76x76x27mm, 24VDC, 12.9CFM, 2.9W, 3500RPM, FlatPak Series
Stock : 0

04701.9-00 electronic component of Stego 04701.9-00

Heater; HGK 047; 20W; 120÷230V; IP44
Stock : 3

04710.0-00 electronic component of Stego 04710.0-00

Heater; HGK 047; 10W; 12÷30V; IP44
Stock : 1

06050.0-00 electronic component of Stego 06050.0-00

Heater; CSK 060; 30W; Uoper: 110÷265V; IP20; Urated: 120/240V
Stock : 9

06040.1-00 electronic component of Stego 06040.1-00

Heater; CSK 060; 10W; Uoper: 12÷30V; IP20; Urated: 24V
Stock : 1

04711.0-00 electronic component of Stego 04711.0-00

Heater; HGK 047; 20W; 12÷30V; IP44
Stock : 6

PHT050 electronic component of PLASTIM PHT050

Heater; 50W; 100÷250V; IP20; DIN rail; 138x70x59mm
Stock : 0

R1G220-AB35-65 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 7938 81-0 or physical damage to both property and people. Fax +49 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. These operating instructions may be duplicated and forwarded for CONTENTS information about potential dangers and their prevention. 1.1 Levels of hazard warnings 1. SAFETY REGULATIONS AND NOTES 1 These operating instructions use the following hazard levels to indicate 1.1 Levels of hazard warnings 1 potentially hazardous situations and important safety regulations: 1.2 Staff qualification 1 DANGER 1.3 Basic safety rules 1 Indicates an imminently hazardous situation which, if not 1.4 Electrical voltage 1 avoided, will result in death or serious injury. Compliance with 1.5 Safety and protective functions 2 the measures is mandatory. 1.6 Electromagnetic radiation 2 WARNING Indicates a potentially hazardous situation which, if not avoided, 1.7 Mechanical movement 2 could result in death or serious injury. Exercise extreme 1.8 Emission 2 caution while working. 1.9 Hot surface 2 CAUTION 1.10 Transport 2 Indicates a potentially hazardous situation which, if not avoided, 1.11 Storage 2 may result in minor or moderate injury or damage of property. 1.12 Disposal 2 NOTE A potentially harmful situation can occur and, if not avoided, can 2. PROPER USE 3 lead to property damage. 3. TECHNICAL DATA 4 1.2 Staff qualification 3.1 Graphic rendition of products 4 Only specialised electrical personnel may install the device, perform the 3.2 Nominal data 5 test run and work on the electrical system. 3.3 Technical description 5 Only trained and authorised specialist personnel are permitted to 3.4 Mounting data 5 transport, unpack, assemble, operate or maintain the device, or to use it in any other manner. 3.5 Transport and storage conditions 5 3.6 Electromagnetic compatibility 5 1.3 Basic safety rules Any safety hazards stemming from the device must be re-evaluated 4. CONNECTION AND START-UP 6 once it is installed in the end device. 4.1 Connecting the mechanical system 6 Observe the following when working on the unit: 4.2 Connecting the electrical system 6 Do not make any modifications, additions or conversions to the 4.3 Connection of the cables 6 device without the approval of ebm-papst. 4.4 Connection diagram 7 1.4 Electrical voltage 4.5 Checking the connections 8 Check the electrical equipment of the device at regular intervals, refer 4.6 Switch on device 8 to chapter 5.2 Safety test. 4.7 Switching off the device 8 Replace loose connections and defective cables immediately. 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 8 WARNING CAUSES AND REMEDIES Terminals and connections have voltage even with a 5.1 Cleaning 9 unit that is shut off Electric shock 5.2 Safety test 9 Wait five minutes after disconnecting the voltage at all poles before opening the device. CAUTION If control voltage is applied or a speed setpoint is stored, the motor automatically restarts, e.g. after a power failure. Danger of injury Item no.: 51563-5-9970 Revision: 75470 Print-out: 2012-02-17 Y. Uhlmann (VM-TDO) Page 1 / 9 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsR1G220-AB35-65 Operating instructions Keep out of the danger zone of the device. 1.8 Emission When working on the device, switch off the mains WARNING supply voltage and secure the latter from being switched on Depending on the installation and operating conditions, again. a sound pressure level greater than 70 dB(A) may arise. Wait until the device stops. Danger of noise-induced hearing loss After working on the device, remove any used tools or Take appropriate technical safety measures. other objects from the device. Protect operating personnel with appropriate safety equipment, e.g. hearing protection. 1.5 Safety and protective functions Also observe the requirements of local agencies. DANGER Missing safety device and non-functioning safety device 1.9 Hot surface If there is no safety device, you could be seriously injured, for CAUTION example by reaching into the running device with your hands. High temperature at the electronics enclosure Operate the device only with a fixed and isolating safety Danger of burn injuries protection and a fixed guard grille. The guard must withstand Ensure that sufficient protection against accidental contact is the kinetic energy of a fan blade detaching at maximum provided. speed. The device is a built-in component. You, the owner/ 1.10 Transport operator, are responsible for providing adequate protection for the device. NOTE Transport of device Instantly stop the device once you detect a missing or ineffective protective feature. Transport the device in its original packaging only. Secure the device so that it does not slip, e.g. by using a 1.6 Electromagnetic radiation clamping strap. Interference from electromagnetic radiation is possible, e.g. in conjunction 1.11 Storage with open and closed-loop control devices. If unacceptable emission intensities occur when the fan is installed, Store the device, partially or fully assembled, in a dry and appropriate shielding measures have to be taken by the user. weatherproof manner in the original packing in a clean environment. NOTE Protect the device from environmental impacts and dirt until the final Electrical or electromagnetic interferences after installation. integrating the device in installations on the customer s We recommend storing the device for a maximum up to one year to side. guarantee proper operation and longest possible service life. Verify that the entire setup is EMC compliant. Even devices explicitly suited for outdoor use are to be stored as described prior to being commissioned. 1.7 Mechanical movement Maintain the storage temperature, see DANGER chapter 3.5 Transport and storage conditions. Rotating device Body parts coming into contact with the rotor and impeller can 1.12 Disposal be injured. When disposing of the device, please comply with all relevant Secure the device against accidental contact. requirements and regulations applicable in your country. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured. Do not wear any loose clothing or jewellery while working on rotating parts. Protect long hair by wearing a cap. Item no.: 51563-5-9970 Revision: 75470 Print-out: 2012-02-17 Y. Uhlmann (VM-TDO) Page 2 / 9 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions

Tariff Desc

FANS AND/OR BLOWERS, DC OR AC, axial OR radial OR crossflow type, having ANY one OR more of the following:
(a) sleeve OR ball OR magnetic bearings;
(c) AC operating voltage NOT less than 115 V and NOT greater than 240 V;
(d) maximum speed exceeding 1 000 RPM;
(e) diameter NOT greater than 300 mm;
(f) height NOT greater than 300 mm;
(g) length NOT greater than 300 mm,
with OR without filters
TC 17129205
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted