Product Information

W1G115-AG03-07

W1G115-AG03-07 electronic component of ebm papst

Datasheet
DC Fans DC Axial Fan, 127x38mm, 24VDC 10W, 52dBA, 3950RPM, Ball Bearing, IP22

Manufacturer: ebm papst
Large
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 130.6611 ea
Line Total: USD 130.66

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Thu. 09 May to Mon. 13 May

MOQ : 1
Multiples : 1

Stock Image

W1G115-AG03-07
ebm papst

1 : USD 128.2171
10 : USD 110.6435
25 : USD 109.085
50 : USD 102.06
100 : USD 99.7338
250 : USD 98.6987

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Series
Brand
Current Type
Product Type
Subcategory
Hts Code
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 33

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 1

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 1

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
FAD1-04020CBLW11 electronic component of Qualtek FAD1-04020CBLW11

DC Fan Axial Ball Bearing 12V 6.999CFM 30dB 40 X 40 X 20mm
Stock : 101

OD1238-24MB electronic component of Orion OD1238-24MB

DC Fans DC Fan, 120x38mm, 24VDC, 95CFM, 0.23A, 41dBA, 2540RPM, Dual Ball Bearing, Wire Leads
Stock : 44

OD9225-12HB electronic component of Orion OD9225-12HB

DC Fans DC Fan, 92x25mm, 12VDC, 53CFM, 0.24A, 35dBA, 2900RPM, Dual Ball Bearing, Wire Leads
Stock : 418

276DM-1LP11-000 electronic component of Etri 276DM-1LP11-000

DC Fan Ball Bearing 12V 0.07A 0.84W 5500RPM 4.6CFM 28dB Flange Mount
Stock : 1

SD8025-24M-S electronic component of Sinwan SD8025-24M-S

24DC 80*80*25 SLV/BRNG 32CFM TUBE AXIAL SLEEVE BEARING
Stock : 1

FAD1-04010BBLW11 electronic component of Qualtek FAD1-04010BBLW11

DC Fan Axial Ball Bearing 5V 4.2CFM 21dB 40 X 40 X 10.5mm
Stock : 131

CFM-A225-13-10 electronic component of CUI Devices CFM-A225-13-10

DC Fan Axial Ball Bearing 12V 6V to 13.8V 126.89CFM 53.5dB 120 X 120 X 25.4mm High Speed
Stock : 1

AUB0824VH electronic component of Delta AUB0824VH

DC Fans DC Tubeaxial Fan, 80x25.4mm, 24VDC, Superflo Bearing, Lead Wires
Stock : 541

109P0412G3023 electronic component of Sanyo Denki 109P0412G3023

DC Fans DC Fan, 40x28mm, 12VDC, Groove for Lead
Stock : 1

3110KL-04W-B40-E00 electronic component of MinebeaMitsumi 3110KL-04W-B40-E00

DC Fan Axial Ball Bearing 12V 6V to 13.8V 35.3CFM 31dB 80 X 80 X 25mm
Stock : 0

W1G115-AG03-07 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 7938 81-0 or physical damage to both property and people. Fax +49 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 potentially hazardous situations and important safety regulations: 1.3 Basic safety rules 1 DANGER 1.4 Electrical voltage 1 Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with 1.5 Safety and protective functions 2 the measures is mandatory. 1.6 Electromagnetic radiation 2 WARNING 1.7 Mechanical movement 2 Indicates a potentially hazardous situation which, if not avoided, 1.8 Emission 2 could result in death or serious injury. Exercise extreme 1.9 Hot surface 2 caution while working. 1.10 Transport 2 CAUTION 1.11 Storage 2 Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. 1.12 Disposal 2 NOTE 2. PROPER USE 3 A potentially harmful situation can occur and, if not avoided, can lead to property damage. 3. TECHNICAL DATA 4 3.1 Graphic rendition of products 4 1.2 Staff qualification 3.2 Nominal data 5 Only specialised electrical personnel may install the device, perform the 3.3 Technical description 5 test run and work on the electrical system. Only trained and authorised specialist personnel are permitted to 3.4 Mounting data 5 transport, unpack, assemble, operate or maintain the device, or to use it 3.5 Transport and storage conditions 5 in any other manner. 4. CONNECTION AND START-UP 6 1.3 Basic safety rules 4.1 Connecting the mechanical system 6 Any safety hazards stemming from the device must be re-evaluated 4.2 Connecting the electrical system 6 once it is installed in the end device. 4.3 Connection via plug 6 Observe the following when working on the unit: 4.4 Connection of the Hall IC 6 Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 4.5 Connection diagram 7 4.6 Checking the connections 8 1.4 Electrical voltage 4.7 Switch on device 8 Check the electrical equipment of the device at regular intervals, refer 4.8 Switching off the device 8 to chapter 5.2 Safety test. Replace loose connections and defective cables immediately. 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 8 CAUSES AND REMEDIES WARNING 5.1 Cleaning 9 Terminals and connections have voltage even with a unit that is shut off 5.2 Safety test 9 Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. CAUTION If control voltage is applied or a speed setpoint is stored, the motor automatically restarts, e.g. after a power failure. Danger of injury Item no.: 51080-5-9970 Revision: 71954 Print-out: 2012-02-24 Y. Uhlmann (VM-TDO) Page 1 / 9 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsW1G115-AG03-07 Operating instructions Keep out of the danger zone of the device. 1.8 Emission When working on the device, switch off the mains WARNING supply voltage and secure the latter from being switched on Depending on the installation and operating conditions, again. a sound pressure level greater than 70 dB(A) may arise. Wait until the device stops. Danger of noise-induced hearing loss After working on the device, remove any used tools or Take appropriate technical safety measures. other objects from the device. Protect operating personnel with appropriate safety equipment, e.g. hearing protection. 1.5 Safety and protective functions Also observe the requirements of local agencies. DANGER Missing safety device and non-functioning safety device 1.9 Hot surface If there is no safety device, you could be seriously injured, for CAUTION example by reaching into the running device with your hands. High temperature at the electronics enclosure Operate the device only with a fixed and isolating safety Danger of burn injuries protection and a fixed guard grille. The guard must withstand Ensure that sufficient protection against accidental contact is the kinetic energy of a fan blade detaching at maximum provided. speed. The device is a built-in component. You, the owner/ 1.10 Transport operator, are responsible for providing adequate protection for the device. NOTE Transport of device Instantly stop the device once you detect a missing or ineffective protective feature. Transport the device in its original packaging only. Secure the device so that it does not slip, e.g. by using a 1.6 Electromagnetic radiation clamping strap. Interference from electromagnetic radiation is possible, e.g. in conjunction 1.11 Storage with open and closed-loop control devices. If unacceptable emission intensities occur when the fan is installed, Store the device, partially or fully assembled, in a dry and appropriate shielding measures have to be taken by the user. weatherproof manner in the original packing in a clean environment. NOTE Protect the device from environmental impacts and dirt until the final Electrical or electromagnetic interferences after installation. integrating the device in installations on the customer s We recommend storing the device for a maximum up to one year to side. guarantee proper operation and longest possible service life. Verify that the entire setup is EMC compliant. Even devices explicitly suited for outdoor use are to be stored as described prior to being commissioned. 1.7 Mechanical movement Maintain the storage temperature, see DANGER chapter 3.5 Transport and storage conditions. Rotating device Body parts coming into contact with the rotor and impeller can 1.12 Disposal be injured. When disposing of the device, please comply with all relevant Secure the device against accidental contact. requirements and regulations applicable in your country. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured. Do not wear any loose clothing or jewellery while working on rotating parts. Protect long hair by wearing a cap. Item no.: 51080-5-9970 Revision: 71954 Print-out: 2012-02-24 Y. Uhlmann (VM-TDO) Page 2 / 9 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions

Tariff Desc

8414.59.90 FANS INCORPORATING BRUSHLESS MOTORS, having ANY of the following:
(a) DC powered;
Op. 19.10.2000 Dec. 05.01.2001 - TC 0008777
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted