Medical Grade MFLS400 Watt AC-DC Power Supplies 400 Watt l 400 Watts Forced Cooled l Efficiency up to 90% l -40 to 70 C operating temperature 3 l High power density : 23.70W/inch th l Meets EN60601-1-2, 4 Edition l Thermal Shut-Down feature / Dual fusing l 2.56m Hours, Telcordia -SR332-issue 3 MTBF l Suitable for BF applications The New MFLS400 Series is designed to work with Forced air cooling. This is a highly efficient power supply that can deliver up to 400 W with air. This new series comes with two options. ie. Casing with Side Fan and Top Fan. 400 Watts 1 Model Number Description Voltage Max. Load Min. Load Ripple 5% with JST Connector MFLS400-1312 12V 25A 0.0A 5% MFLS400-1315 with JST Connector 15V 20A 0.0A 2% with JST Connector MFLS400-1324 24V 16.70A 0.0A 2% MFLS400-1330 with JST Connector 30V 13.30A 0.0A 2% with JST Connector MFLS400-1348 48V 8.30A 0.0A 2% MFLS400-1358 with JST Connector 58V 6.90A 0.0A For Top FAN vesrion add TF Ex. MFLS400-1324-TF For Side FAN version add SF Ex. MFLS400-1324-SF Pin Connection AC LINE PIN 1 J1 (Input) PIN 2 NOT FITTED AC NEUTRAL PIN 3 PIN 1,2,3 V1 +VE J2 (Output) V1 -VE PIN 4,5,6 Earth Self clinching nut +VS (Remote Sense) (J9) PIN 1 PIN 2 -VS (Remote Sense) Signal Connector www.eospower.com 4EM-21-295 1 39-DE60-41055-002 / A Medical Grade MFLS400 Watt AC-DC Power Supplies Notes 1. Ripple is peak to peak with 20 MHz bandwidth and 10 F (Tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 2. Specifications are for nominal input voltage, 25C unless otherwise stated. 3. 400W with Forced cooling at 115 VAC to 264VAC. 4. Combine Output Power of Main Output, Fan supply should not exceed 400 W. 5. Output ripple can be more than 2 % of the output voltage. Input Characteristic Minimum Typical Maximum Units Notes & Conditions 85 264 VAC De-rate linearly from 100% at 115VAC to 70% at 85VAC Input Voltage 47 Hz Input Frequency 63 6.3 A Input Current A Inrush Current 75 exceeds 0.95 at Full Load Power Factor Output Characteristic Minimum Typical Maximum Units Notes & Conditions W 400 Output Power At 230 VAC 8mS Hold-up Time +/-0.5% Line Regulation +/-0.5% Load Regulation +/-3% Output Voltage Adjustability 55 ms Rise Time +/-1% Set Point Tolerance > 105% Over Current Protection 110 to 140% Over Voltage Protection 25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% , recovery time < 5 ms Transient Response General Characteristic Minimum Typical Maximum Units Notes & Conditions 90% At 230 VAC Efficiency 2.56m Hours Telcordia -SR332-issue 3 Mean Time Between Failure 4380 Input to Output: 4380VAC (2x MOPP), Isolation: Input to Output 1690 VAC Input to Ground: 1690VAC (1x MOPP), Input to Ground 1500 Output to Ground: 1500VAC (1x MOPP) Output to Ground Leakage Current 300 uA Typical Touch current <100uA www.eospower.com 4EM-21-295 2 39-DE60-41055-002 / A