XR38 Power entry module for 106/1140/1658/2-5700/8330 Description The XR38 power entry module for circuit breakers with 3/8 threadneck combines up to 3 functions in one component. A C14 appliance inlet, a resettable overcurrent protection and a line filter. Appropriate line filters can be selected for the use of the power entry module in medical equipment applications according to IEC/ EN60601-1. You can choose between two standard versions: version C without actuator guard (reset button protrudes from the module) and version D with actuator guard (reset button completely recessed). Screw-type mounting from the front or from the rear. Combination of XR38 with 16658 only available in the USA. 1 Typical applications XR38 Medical apparatus, laboratory equipment, professional kitchen equipment, 3D printers etc. Technical data Ordering information Type no. Rated voltage AC 250 V XR38 Power entry module for 106, 1140, 1658, 2-5700, 8330 Current rating 10 A (IEC/EN) (1) circuit breakers 15 A (UL/CSA) (C14 appliance inlet with/ Module without filter) C Push button protruding D Push button recessed Operating temperature -25 C +60 C Mounting method Number of poles L, N ,+mass 04 Screw-type mounting Filters Degree of protection I 00 Without Mounting method Screw-type mounting (from the front 01 Standard line filter or from the rear) 03 Standard line filter for medical equipment 06 High performance line filter for medical equipment Terminals C14 and circuit breaker: (2) Filter rating (for version with filter only) Blade terminals 6.3 x 0.8 mm 01 1 A Enclosure material Thermoplastics, black, UL94V-0 03 3 A support plate 06 6 A 08 8 A Appliance inlet C14 10 10 A Circuit breaker for 106, 1140, 1658, 2-5700, 8330 12 12 A equipment protection 15 15 A Version (3) 11 Wired Supply status M Module supplied with circuit breaker mounted XR38 C 04 01 03 11 M Ordering example (1) Only the following versions are available with 3/8 threadneck and blade terminals 6.3 x 0.8mm. 106-iG0-...-P10 1140-G0-...-P1/P7 1658-G21-00-P10 2-5700-iG0-P10-... 8330-GN..., terminal P (2) For the selection of the filter current rating refer to the table in the data sheet. The current rating of the circuit breaker must not be higher than the filter current rating. (3) For single pole circuit breakers, only one wire is routed from the circuit breaker to the C14 appliance inlet when ordered as wired. Accessories such as water splash cover upon request. 2114 www.e-t-a.de 1XR38 Power entry module for 106/1140/1658/2-5700/8330 Mounting cut-out 1 0.4 65 2.56 +0.4 75 2.95 Schematic diagrams Standard filter (C0401, D0401) Cx 2xL2xCy N 12 21 12 1 2 3 4 N 106 1658 2-5700 PE PE 1140 8330 P 3 4 1 2 Line P Load Filter for medical equipment (C0403, C0406, D0403, D0406) 12 21 12 Cx RN2xL 1 2 3 4 106 1658 2-5700 N PE 1140 8330 PE P Line P 3 4 1 2 Load All information and data given on our products are accurate and reliable to the best of our knowledge, but E-T-A does not accept any responsibility for the use in applications which are not in accordance with the present specification. E-T-A reserves the right to change specifications at any time in the interest of improved design and performance. Dimensions are subject to change without notice. Please enquire for the latest dimensional drawing with tolerances if required. All dimensions, data, pictures and descriptions are for information only and are not binding. Amendments, errors and omissions excepted. Part numbers of the devices may differ from their marking. 2 www.e-t-a.de 2114 M3 / 3.3 .130 0.4 36.5 1.44