Ericsson InternalEricsson Internal E PRODUCT STABLE OF CONTEPECIFICATION NTS 1 (1)1 (4) PrPreparepareedd ( (aallsso so subjubjecectt r reesponsisponsibbllee i iff othotheerr)) NNoo SEC/S MarshSEC/S Marshaall ll 1/130100152-E-BMR N/LZ455 00T 146 443 Uen Technical Specication AApppprroovveedd Ch Cheeckecked d DaDate te ReRev v ReRefefererenncce e EN/LZT 146 430 R3A March 2014 PIM 4000 EAB/FAC/P series Power Interface Modules2013-02-07 2013-02-06 PB4 A D 0 Ericsson AB Input 36-75 V, Output up to 10-12 A / 540-648 W Key Features Industry standard low profile Quarter-brick 57.9 x 36.8 x 13.7 mm (2.28 x 1.45 x 0.539 in) 400 W at 40 Vin, 480 W at 48 Vin, 540 W at 54 Vin High efficiency, typ. 99% at 300 W 10 A output current at 70C 0.5 m/s (100 LFM) airflow Low EMI design for CISPR Class B 2 Monitoring via I C 2250 Vdc input to output isolation Optimized for ATCA applications Basic insulation according to UL 60950-1 MTBF 1.8 Mh General Characteristics Dual power feeds input and enable Input transient suppression (IEC & ANSI standards) Reverse polarity protection Safety Approvals Design for Environment Input under voltage shutdown Over temperature protection Output current protection A/B Feed loss alarm Meets requirements in high- Inrush protection and hot swap functionality temperature lead-free soldering processes. Hold-up charge and management 12 W dual management power output Highly automated manufacturing ensures quality ISO 9001/14001 certified supplier Contents Ordering Information ............................................................. 2 General Information ............................................................. 2 Safety Specification ............................................................. 3 Absolute Maximum Ratings ............................................................. 4 Electrical Specification 10-12A/ 3.3V, 3.6A/ 5.0V, 0.15A PIM 4328 P....................................... 5 Application Circuit Diagram ........................................................... 16 EMC Specification ........................................................... 17 Operating Information ........................................................... 18 Thermal Consideration ........................................................... 20 Connections ........................................................... 21 I2C/PM Bus Interface ........................................................... 22 Mechanical Information ........................................................... 25 Soldering Information ........................................................... 26 Delivery Package Information ........................................................... 26 Product Qualification Specification ........................................................... 27 Ericsson Internal E PRODUCT SPECIFICATION 2 (4) Prepared (also subject responsible if other) No. SEC/S Marshall 1/1301-BMR 455 00 2 Technical Specication Approved Checked Date Rev Reference EN/LZT 146 430 R3A March 2014 PIM 4000 series Power Interface Modules2013-02-06 PB4 0 Ericsson AB Input 36-75 V, Output up to 10-12 A / 540-648 W Compatibility with RoHS requirements Ordering Information The products are compatible with the relevant clauses and Product program Output requirements of the RoHS directive 2002/95/EC and have a PIM 4328 10-12A/ 3.3V, 3.6A / 5V, 0.15A maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent Product number and Packaging chromium, PBB and PBDE and of 0.01% by weight in PIM 4XXX n n n n 1 2 3 4 homogeneous materials for cadmium. Options n n n n 1 2 3 4 Mounting Exemptions in the RoHS directive utilized in Ericsson Power Modules products are found in the Statement of Function Compliance document. Lead length Delivery package information Ericsson Power Modules fulfills and will continuously fulfill all its obligations under regulation (EC) No 1907/2006 Options Description concerning the registration, evaluation, authorization and restriction of chemicals (REACH) as they enter into force n P Through hole 1 and is through product materials declarations preparing for the obligations to communicate information on substances n Analog* 2 in the products. D Standard config PMBus 2 DA Limited I C (Industry standard) Quality Statement n 5.33 mm * 3 The products are designed and manufactured in an LA 3.69 mm industrial environment where quality systems and methods LB 4.57 mm like ISO 9000, Six Sigma, and SPC are intensively in use to boost the continuous improvements strategy. Infant n Soft tray * 4 mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Example a through-hole mounted, PMBus logic, standard pin product with Conservative design rules, design reviews and product tray packaging would be PIM 4328PD. qualifications, plus the high competence of an engaged work force, contribute to the high quality of the products. * Standard variant (i.e. no option selected). Warranty General Information Warranty period and conditions are defined in Ericsson Reliability Power Modules General Terms and Conditions of Sale. The failure rate () and mean time between failures Limitation of Liability (MTBF= 1/ ) is calculated at max output power and an operating ambient temperature (T ) of +40C. Ericsson A Ericsson Power Modules does not make any other Power Modules uses Telcordia SR-332 Issue 2 Method 1 to warranties, expressed or implied including any warranty of calculate the mean steady-state failure rate and standard merchantability or fitness for a particular purpose deviation ( ). (including, but not limited to, use in life support applications, where malfunctions of product can cause Telcordia SR-332 Issue 2 also provides techniques to injury to a persons health or life). estimate the upper confidence levels of failure rates based on the mean and standard deviation. Ericsson AB 2013 Mean steady-state failure rate, Std. deviation, The information and specifications in this technical specification is believed to be correct at the time of 531 nFailures/h 47 nFailures/h publication. However, no liability is accepted for inaccuracies, printing errors or for any consequences MTBF (mean value) for the PIM series = 1.83 Mh. thereof. Ericsson AB reserves the right to change the MTBF at 90% confidence level = 1.65 Mh contents of this technical specification at any time without prior notice.