FTR-K1 SERIES Non-promotional not for new designs POWER RELAY 1 POLE - 10A VS Series n FEATURES l UL, CSA, VDE, SEV, SEMKO, CQC recognized l TV-5 is available l Working class: C l UL class B (130C) coil wire insulation l Type of service: continuous duty l Heavy duty miniature slim type power relay l High isolation in small package - Insulation distance: 8 mm - Dielectric strength: 5,000 VAC (between coil and contacts) - Surge strength: 10,000 V l Standard and high sensitivity types available l Flux proof type and plastic sealed type available l Cadmium free is available l RoHS compliant. Please see page 8 for more information n PARTNUMBER INFORMATION VS - 12 S M B U - N - UC Example (a) (*) (b) (c) (d) (e) (f ) (g) (h) (a) Relay type VS : VS Series (b) Coil rated voltage 12 : 3....100VDC Coil rating table at page 3 (c) Coil type Nil : Standard type (700-750mW) S : High sensitive type (530mW) (d) Contact configuration T : 1 form C (SPDT) M : 1 form A (SPST-NO) (e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII (f) TV type Nil : TV rating type U : Non TV rating type (standard type) (g) Contact material N : Silver alloy (10A) (AgSnO ) 2 Nil : Silver-cadmium oxide (TV-5 rating) (AgCdO) 5 : Silver-cadmium oxide (non TV rating) (AgCdO) Nil : Gold overlay silver-nickel (non TV rating) (AgNi + Au) E : Silver-nickel (non TV rating) (AgNi) (h) Safety standard UC : UL, CSS SM2 : UL, CSA, VDE, SEMKO IM2 : UL, CSA, VDE, SEV, SEMKO 1 Note: Actual marking omits the hyphen (-) of (*)FTR-K1 SERIES VS SERIES n SPECIFICATION TV-5 Rating Type Standard Type VS - ( ) U VS - ( ) M VS - ( ) MN VS - ( )U-5 VS - ( ) U-N VS - ( ) U-E Contact Configuration 1 form A (SPST-NO), 1 form C (SPDT) Data Construction Single Silver cad- Silver cad- Gold overlay Material Silver alloy Silver alloy mium-oxide mium-oxide silver nickel Resistance (initial) Max. 100mOhm at 6VDC, 1A Contact rating 10A, 240VAC / 24VDC Max. carrying current * 14A Max. switching voltage 250VAC, 150 VDC Max. switching power 2,400VA, 240W Max. inrush current (at lamp load) 78A, 120VAC - Min. switching load * 100 mA, 5 VDC (M, 5, E), 10mA 5 VDC (VS-) 6 Life Mechanical Min. 20 x 10 operations 3 Contact rating Min. 100 x 10 operations 3 Motor Min. 30 x 10 operations 3 Min. 50 x 10 operations Electrical (at 78A, 120VAC, lamp) Lamp - 3 Min. 15 x 10 operations (high senstive type) Coil Data Rated power (at 20 C) 700-750 mW standard type, 530 mW high sensitive type Operate power (at 20 C) 350-370 mW standard type, 350 mW high sensitive type -40 C to +85 C standard type, 40 C to +75 C high sensitive type Operating temperature range (no frost) Timing Data Operate (at nominal voltage) Max. 15 ms (without bounce) Release (at nominal voltage) Max. 10 ms (no diode) Insulation Resistance (initial) Min. 1,000MOhm at 500VDC Dielectric strength Open contacts 1,000VAC (50/60Hz) 1min., 10mA detection current Contacts to coil 5,000VAC (50/60Hz) 1min., 10mA detection current Surge strength Coil to contacts 10,000V, 1.2 x 50s standard wave Clearance 8 mm Creepage 8 mm EN61810-1, VDE0435 Voltage 250 V Pollution degree 2 Material group III Other Misoperation 10 to 55Hz double amplitude 1.5 mm Vibration resistance Endurance 10 to 55Hz double amplitude 1.5 mm Misoperation Min. 100m/s (11 1ms) Shock Endurance Min. 1,000m/s (6 1ms) Weight Approximately 17 g *1 When max. carrying current is more than 10A, PCB layout needs to be considered. *2 Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actual load before production since reference values may vary according to switching frequencies, environmental contions and expected reliability levels. 2