Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors
13 mm Series
FEATURES
Rugged, isolated stainless
steel package
Reliable semiconductor
technology
Calibrated and
temperature compensated
Voltage or current supply
options
Honeywells 13 mm Series stainless steel pressure sensors are designed
Absolute and sealed gage
for high pressure applications that involve measurement of hostile media in
pressures
harsh environments. This series uses Honeywells proven piezoresistive
Low-cost cell package
semiconductor sensor chip in an oil-isolated housing with or without an
Absolute pressure
integral ceramic for temperature compensation and calibration. This design
0 psi to 500 psi, 1000 psi,
has proven to be highly reliable, stable and accurate.
2000 psi, 3000 psi, and
These sensors feature a weld-ring collar and special back support ring for
5000 psi
high cycle life capability as they are designed for further package integration
in OEM (Original Equipment Manufacturer) applications. Products are
available with pressure ranges from 500 psi through 5000 psi and can be
TYPICAL APPLICATIONS
used with voltage or current supplies.
Industrial controls
Hydraulic controls
EQUIVALENT CIRCUIT
Tank pressure
Pressure transmitters
Process control systems
13 mm compensated series 13 mm uncompensated series
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
WARNING
in any other application
MISUSE OF DOCUMENTATION
where failure of the product
The information presented in this product sheet is for reference only. Do
could result in personal
not use this document as a product installation guide.
injury.
Complete installation, operation, and maintenance information is provided
Failure to comply with
in the instructions supplied with each product.
these instructions could
Failure to comply with these instructions could result in death or
result in death or serious
serious injury.
injury.
Sensing and Control Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors
13 mm Series
PRESSURE SENSOR CHARACTERISTICS (all devices)
Environmental specifications
Compensated temperature range 0 C to 82 C [32 F to 180 F]
Operating temperature range -40 C to 125 C [-40 F to 257 F]
Storage temperature range -40 C to 125 C [-40 F to 257 F]
Vibration 10 G at 20 Hz to 2000 Hz
Shock 100 G for 11 ms
Life 1 million cycles min.
Insulation resistance 100 m at 50 Vdc
Maximum ratings
Voltage version K Supply voltage V = +15 Vdc
S
Voltage version L Supply current I = +2.0 mA
S
(1)
PERFORMANCE CHARACTERISTICS COMPENSATED SERIES
Characteristic Minimum Typical Maximum Units
Zero pressure offset -2 0 +2 mV
(3)
Pressure non-linearity 0.1 0.25 %FSS
(3)
Pressure hysteresis 0.015 0.030 %FSS
Repeatability 0.010 0.030 %FSS
(4)
Temp. effect on span 0.5 1.0 %FSS
(4)
Temp. effect on offset 0.5 1.0 %FSS
Thermal hysteresis (0 C to 82 C [32 F to 180 F]) 0.1 0.3 %FSS
(5)
Long-term stability of offset and span 0.1 0.3 %FSS
(6)
Response time 0.1 ms
(9)
Common mode voltage (voltage version K) 0.50 1.25 2.0 Vdc
Input resistance (current version L) 2.0 4.5 8.0 k
Input resistance (voltage version K) 8.0 25 50 k
Output resistance 3.0 4.5 6.0 k
PRESSURE RANGE SPECIFICATIONS COMPENSATED SERIES
(2) (7) (8)
Catalog Listing Pressure range Full scale span Proof pressure Burst pressure
13C 0500P (A,S) (1,4,5,6) (K,L) 0 psi to 500 psi 98 mV to 102 mV 1500 psi 2500 psi
13C 1000P (A,S) (1,4,5,6) (K,L) 0 psi to 1000 psi 98 mV to 102 mV 3000 psi 5000 psi
13C 2000P (A,S) (1,4,5,6) (K,L) 0 psi to 2000 psi 98 mV to 102 mV 6000 psi 10,000 psi
13C 3000P (A,S) (1,4,5,6) (K,L) 0 psi to 3000 psi 98 mV to 102 mV 9000 psi 10,000 psi
13C 5000P (A,S) (1,4,5,6) (K,L) 0 psi to 5000 psi 148 mV to 152 mV 10,000 psi 10,000 psi
NOTES
1. Reference conditions (unless otherwise noted): T = 25 C [77 F]; Supply V = 10 Vdc 0.01 Vdc or I = 1.5 mA
A S S
0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 C [77 F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducers performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
case.
9. Common mode voltage as measure from output to ground.
2 Honeywell Sensing and Control