Data Sheet Flexible RF cable RG 400 /U Item: 22510080 Description RG: RG type RF cables RG400, 50 Ohm, 6 GHz, 200C, 4.95 mm, FEP jacket Technical Data Construction Material Detail Diameter Centre conductor Copper, Silver plated Strand-19 1 mm Dielectric PTFE (Polytetrafluoroethylene) 2.95 mm Outer conductor Copper, Silver plated Braid, 97% 3.6 mm Outer conductor Copper, Silver plated Braid, 94 % 4.2 mm Jacket FEP (Fluorinated ethylene propylene) RAL 8015 - br 4.95 mm +/- 0.1 Print: HUBER+SUHNER RG 400 U 50 Ohm (production order number) Electrical Data Impedance 50 +/- 2 Operating Frequency 6 GHz Capacitance 94 pF/m Velocity of signal propagation 69 % Signal delay 4.75 ns/m Screening effectiveness 81 dB (up to 6 GHz) Operating voltage 1.7 kV (at sea level) rms Test voltage 3.4 kV (50 Hz/1 min) rms Mechanical Data Weight 6.4 kg/100 m Min. bending radius static 30 mm 50 mm dynamic 75 mm Environmental Data Temperature range -65 C ... +200 C Installation temperature -20 C... +60 C Flame propagation test IEC 60332-3, Halogen free No 2011/65/EU (RoHS - including compliant 2015/863 and 2017/2102) 1907/2006/EC (REACH) compliant Additional Information MIL reference: M17/128-RG400 Remarks (For details refer to the HUBER+SUHNER RF CABLES GENERAL CATALOGUE or contact your nearest HUBER+SUHNER partner) Suitable Connectors Cable group U11 3 mm / 50 Ohm Document: DOC-0000177787 AY / PDO O / date of publication: 03.03.2021 17:29:15 / uncontrolled copy Page 1/2Data Sheet Flexible RF cable RG 400 /U Item: 22510080 Matrix typical Attenuation formula: (a*f 0.5 + b*f) and maximum Power CW formula: (p/f 0.5) Coefficients: a = 0.3894 b = 0.0925 f = 6 P at 1GHz = 365 max Frequency Nom. attenuation Nom. attenuation Max. CW power (GHz) (dB / m) (dB / ft) (W) sea level 25 C sea level 25 C sea level 40 C ambient ambient ambient temperature temperature temperature 0,3 0,24 0,073 666 0,6 0,36 0,109 471 0,9 0,45 0,138 385 1,2 0,54 0,164 333 1,5 0,62 0,188 298 1,8 0,69 0,210 272 2,1 0,76 0,231 252 2,4 0,83 0,252 236 2,7 0,89 0,271 222 3,0 0,95 0,290 211 3,3 1,01 0,309 201 3,6 1,07 0,327 192 3,9 1,13 0,344 185 4,2 1,19 0,362 178 4,5 1,24 0,379 172 4,8 1,3 0,395 167 5,1 1,35 0,412 162 5,4 1,4 0,428 157 5,7 1,46 0,444 153 6,0 1,51 0,460 149 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS. www.hubersuhner.com Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind. Document: DOC-0000177787 AY / PDO O / date of publication: 03.03.2021 17:29:15 / uncontrolled copy Page 2/2