pHE850 RoHS Compliant Emi suppressor, class y2, metallized polypropylene 0.001 1.0 f, 300 vac, +110 c new, small dimensions including low profile capacitors L B tYpiCaL appLiCations ConstRuCtion The capacitors are intended for use as Winding of metallized polypropylene. interference suppressors in Y2 (line-to- Encapsulated in self-extinguishing material H earth) applications. meeting the requirements of UL 94V-0. 0.5 Not for use in series with the mains. See www.kemet.com for more information. p d l b tECHniCaL data rated voltage 300 VAC, 50/60 Hz (ENEC,UL,cUL) p d std l max l b 10.0 0.4 0.6 17 30 0.4 capacitance range f 0.0011.0 15.0 0.4 0.6/0.8* 17 30 0.4 22.5 0.4 0.8 6 30 0.4 t emperature range c 55/+110 27.5 0.4 0.8 6 30 0.4 37.5 0.5 1.0 6 30 0.7 climatic category iEc 55/110/56/B * Size 7.5 x 14.5 x 18.0 and bigger, d = 0.8 capacitance tolerance 20% standard, other tolerances on request mm. approvals ENEC, UL, cUL Tolerance in lead length +0 < 30 mm mm 1 dissipation factor tan Maximum values at +23 C C 0.1 F 0.1 F < C 1 F C > 1 F +5 30 mm mm 0 1 kHz 0.2% 0.15% 0.1% 10 kHz 0.3% 0.4% 0.8% 100 kHz 0.6% insulation resistance C 0.33 F: 30 000 M C > 0.33 F: 10 000 s resonance frequency Tabulated self-resonance frequencies f refer to 5 mm 0 lead lengths. t est voltage between The 100% screening factory test is carried out at 5000 terminals VDC and 2500 VAC. The voltage level is selected to meet the requirements in applicable equipment standards. All electrical characteristics are checked after the test. in dc applications Recommended voltage: 1250 VDC EnViRonmEntaL tEst data Endurance EN/IEC 60384-14:2005 1.7 x U VAC 50 Hz, once every hour R increased to 1000 VAC for 0.1 s, 1000 h at upper rated temperature vibration IEC 60068-2-6, Test Fc 3 directions at 2 hour each, No visible damage, No open or short circuit 2 10 55 Hz at 0.75 mm or 98 m/s 2 Bump IEC 60068-2-29, Test Eb 1000 bumps at 390 m/s No visible damage, No open or short circuit change of temperature IEC 60068214 Upper and lower rated No visible damage Test Na temperature 5 cycles active flammability EN/IEC 60384-14:2005 Passive flammability EN/IEC 60384-14:2005 humidity IEC 60068-2-3, Test Ca +40C and 90 95% R.H. 56 daysPhE850 aRtiCLE taBLE capaci- Box max dimensions max capaci- Box max dimensions max tance code in mm f du/dt article code tance code in mm f du/dt article code o o f B h l mhz v/s f B h l mhz v/s lEad sP acinG 10 mm lEad sP acinG 22.5 mm 0.0010 A06 4.0 8.0 13.0 50 100 PHE850EA4100MA06R17 0.033 D13 6.5 14.5 26.0 5.7 100 PHE850ED5330MD13R06L2 0.0012 A06 4.0 8.0 13.0 45 100 PHE850EA4120MA06R17 0.039 D13 6.5 14.5 26.0 5.4 100 PHE850ED5390MD13R06L2 0.0015 A01 4.0 9.0 13.0 43 100 PHE850EA4150MA01R17 0.047 D13 6.5 14.5 26.0 5.0 100 PHE850ED5470MD13R06L2 0.0018 A01 4.0 9.0 13.0 40 100 PHE850EA4180MA01R17 0.056 D17 7.0 16.5 26.0 4.7 100 PHE850ED5560MD17R06L2 0.0022 A01 4.0 9.0 13.0 36 100 PHE850EA4220MA01R17 0.068 D17 7.0 16.5 26.0 4.3 100 PHE850ED5680MD17R06L2 0.0027 A02 4.5 10.5 13.0 34 100 PHE850EA4270MA02R17 0.082 D15 9.0 18.5 26.0 4.0 100 PHE850ED5820MD15R06L2 0.0033 A02 4.5 10.5 13.0 31 100 PHE850EA4330MA02R17 0.10 D18 10.5 19.0 26.0 3.6 100 PHE850ED6100MD18R06L2 0.0039 A03 5.0 11.0 13.0 29 100 PHE850EA4390MA03R17 0.12 D18 10.5 19.0 26.0 3.3 100 PHE850ED6120MD18R06L2 0.0047 A03 5.0 11.0 13.0 26 100 PHE850EA4470MA03R17 0.15 D16 11.0 21.5 26.0 2.8 100 PHE850ED6150MD16R06L2 0.0056 A04 6.0 12.0 13.0 23 100 PHE850EA4560MA04R17 0.18 D20 13.5 23.0 26.0 2.5 100 PHE850ED6180MD20R06L2 0.0068 A04 6.0 12.0 13.0 20 100 PHE850EA4680MA04R17 0.22 D20 13.5 23.0 26.0 2.3 100 PHE850ED6220MD20R06L2 0.0068 A05 9.5 7.5 13.0 21 100 PHE850EP4680MA05R17 lEad sP acinG 27.5 mm lEad sP acinG 15 mm 0.15 F11 10.5 20.5 31.5 2.4 100 PHE850EF6150MF11R06L2 0.0068 B04 5.5 10.5 18.0 14 100 PHE850EB4680MB04R17 0.15 F17 21.0 12.5 31.5 2.4 100 PHE850ET6150MF17R06L2 0.0082 B04 5.5 10.5 18.0 14 100 PHE850EB4820MB04R17 0.18 F11 10.5 20.5 31.5 2.2 100 PHE850EF6180MF11R06L2 0.010 B04 5.5 10.5 18.0 13 100 PHE850EB5100MB04R17 0.22 F12 11.5 22.5 31.5 2.1 100 PHE850EF6220MF12R06L2 0.012 B05 5.5 12.5 18.0 12 100 PHE850EB5120MB05R17 0.27 F03 13.5 23.0 31.5 1.9 100 PHE850EF6270MF03R06L2 0.015 B15 6.0 12.0 18.0 11 100 PHE850EB5150MB15R17 0.33 F13 14.5 24.5 31.5 1.7 100 PHE850EF6330MF13R06L2 0.018 B10 6.5 12.5 18.0 10 100 PHE850EB5180MB10R17 0.39 F14 17.5 28.0 31.5 1.6 100 PHE850EF6390MF14R06L2 0.022 B06 7.5 14.5 18.0 9.5 100 PHE850EB5220MB06R17 0.47 F14 17.5 28.0 31.5 1.4 100 PHE850EF6470MF14R06L2 0.027 B06 7.5 14.5 18.0 8.6 100 PHE850EB5270MB06R17 0.47 F19 27.5 16.0 31.5 1.5 100 PHE850ET6470MF19R06L2 0.033 B12 8.0 15.0 18.0 7.8 100 PHE850EB5330MB12R17 0.56 F16 21.0 30.0 31.5 1.3 100 PHE850EF6560MF16R06L2 0.039 B11 8.5 16.0 18.0 7.0 100 PHE850EB5390MB11R17 0.68 F16 21.0 30.0 31.5 1.2 100 PHE850EZ6680MF16R06L2 * 0.047 B14 9.5 17.5 18.0 6.3 100 PHE850EB5470MB14R17 0.047 B17 13.0 12.5 18.0 6.3 100 PHE850EH5470MB17R17 lEad sP acinG 37.5 mm 0.056 B16 11.0 19.0 18.0 5.5 100 PHE850EB5560MB16R17 0.068 B16 11.0 19.0 18.0 4.7 100 PHE850EB5680MB16R17 0.33 R05 13.0 24.0 41.0 1.2 100 PHE850ER6330MR05R06L2 0.39 R05 13.0 24.0 41.0 1.1 100 PHE850ER6390MR05R06L2 0.47 R05 13.0 24.0 41.0 1.1 100 PHE850ER6470MR05R06L2 0.56 R04 15.0 26.0 41.0 1.0 100 PHE850ER6560MR04R06L2 0.68 R02 16.5 32.0 41.0 0.94 100 PHE850ER6680MR02R06L2 0.82 R02 16.5 32.0 41.0 0.88 100 PHE850ER6820MR02R06L2 1.0 R03 19.0 36.0 41.0 0.81 100 PHE850ER7100MR03R06L2 1.2 R06 21.0 38.0 41.0 0.74 100 PHE850ER7120MR06R06L2 1.5 R06 21.0 38.0 41.0 0.66 100 PHE850EW7150MR06R06L2 * 1.8 R08 28.0 43.0 41.0 0.58 100 PHE850ER7180MR08R06L2 2.2 R08 28.0 43.0 41.0 0.54 100 PHE850ER7220MR08R06L2 * Only 20% tolerance 20% tolerance appRoV aLs maRKing certification Body specification RIFA RIFA article code ENEC EN/IEC 60384-14:2013 Rated capacitance Capacitance tolerance code UL UL 60384-14 Rated voltage Y2 CAN/CSA-E60384-14:09 Approval marks IEC Climatic category Passive flammability class Manufacturing date code oRdERing inFoRmation The article code for the standard part is given in the article table. Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute and we specifically disclaim any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.