Product Information

L200-TC

Product Image X-ON

Datasheet
THERMOMETER/LOGGER, DIGITAL, T/C
Manufacturer: Labfacility



Price (USD)

1: USD 1230.4041 ea
Line Total: USD 1230.4041

2 - Global Stock
Ships to you between
Wed. 29 Mar to Tue. 04 Apr
MOQ: 1 Multiples:1
Pack Size :   1
Availability Price Quantity
2 - Global Stock


Ships to you between Wed. 29 Mar to Tue. 04 Apr

MOQ : 1
Multiples : 1

Stock Image

L200-TC
Labfacility

1 : USD 1230.4041

     
Manufacturer
Labfacility
Product Category
Environmental Test Equipment
Accuracy
0.1 %
Brand
Labfacility
Temperature Measuring Range
0 C To + 50 C
Thermocouple Type
B, E, J, K, N, R, S, T
External Height
62 mm
External Width
214 mm
Operating Temperature Min
0 C
Operating Temperature Max
50 C
External Depth
138 mm
Product Range
L200 Series
Svhc
No SVHC (15 - Jan - 2019)
External Length / Height
62 mm
Logging Intervals
5 Seconds To 1 Hour
Memory Capacity
512 Sets Of Readings
No. Of Inputs
8
Operating Temperature Range
0 C To + 50 C
Resolution
0.1C
Supply Voltage V Dc
6 V
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image L-PL-K (IEC)
L-PL-K (IEC)
Stock : 7
Stock Image MA-ISK-S15-100-P1-2.0-C2-T
MA-ISK-S15-100-P1-2.0-C2-T
Stock : 19
Stock Image MA-ISK-S10-250-P1-2.0-C2-T
SENSOR, T/COUPLE, MI, K, S/S, 1X250MM
Stock : 0
Stock Image MA-ISK-S10-100-P1-2.0-C2-T
SENSOR, T/COUPLE, MI, K, S/S, 1X100MM
Stock : 15
Stock Image MA-ISK-S10-100-P1-1.0-C2-T
SENSOR, T/COUPLE, MI, K, S/S, 1X100MM
Stock : 15
Stock Image MA-ISK-I30-500-P1-2.0-C1-T
SENSOR, THERMOCOUPLE, K, 0.5M, 1100DEG C
Stock : 0
Stock Image MA-ISK-I10-500-P1-2.0-C1-T
SENSOR, THERMOCOUPLE, K, 0.5M, 750DEG C
Stock : 0
Stock Image LX101
LUX METER, 50000LX, HAND HELD
Stock : 0
Stock Image L250
L250
Stock : 0
Stock Image MA-ISK-S15-1000-P1-2.0-C2-T
SENSOR, T/COUPLE, MI, K, S/S, 1.5X1000MM
Stock : 0
Image Description
Stock Image CHECKTEMP
THERMOMETER, STICK TYPE
Stock : 10
Stock Image CHECKTEMP 1
THERMOMETER, DIGITAL, -50°C TO 150°C
Stock : 0
Stock Image 80AK-A
Environmental Test Equipment THERMOCOUPLE ADAPT
Stock : 1
Stock Image FM-216-AR2-P
Sensor: gas flow; Usup:12÷24VDC; Range: ±9999999l; 0÷50°C; IP40
Stock : 0
Stock Image BMP280
Board Mount Pressure Sensors Digital Barometer 2.7uA, 300-1200hPa
Stock : 17830
Stock Image 60101-0301
THERMAL IMAGER, 140 X 140, 9HZ, FLIR I7
Stock : 0
Stock Image 365515
Environmental Test Equipment STOPWATCH, BIG DIGIT/BACKLIT DISPLAY
Stock : 0
Stock Image S-11
Environmental Test Equipment 6" Rubber Wheel Assembly with Standa
Stock : 112
Stock Image 80PK-1
Environmental Test Equipment PROBE, THERMOCOUPLE, BEADED K-TYPE
Stock : 6
Stock Image 80PK-27
Environmental Test Equipment SUREGRIP, INDUSTRIAL SURFACE TEMPERATURE PROBE
Stock : 0

LABFACILITY L200 USB HIGH PRECISION DIGITAL THERMOMETER/DATA LOGGER The Labfacility L200 Pt100 and thermocouple thermometer can be used in conjunction with a PC to provide accurate, versatile 8 channel thermocouple and Pt100 temperature measurement, scanning and logging of measured values. It can also be used as a stand alone indicator/logger and incorporates a digital display of measured temperature. The in-built, self-calibration facility for the thermocouple version is a rapid and convenient method for on-site calibration and does not require any additional equipment other than a special, external link. Self-calibration of Pt100 ranges is equally simple and uses plug-in precision resistors. The L200 is designed to provide exceptional stability with high measurement resolution and represents an ideal crossover between plant practicality and laboratory performance at a very competitive price. The PC software supplied with the instrument allows control, measure and calibration functions. Low cost high performance USB PC interface 8 thermocouple (type J,K,T,E,N,R,S & B) or Pt100 (3 wire) inputs Built-in display for selected channel or all channels auto-scrolling Resolution 0.1C on L200 display, 0.01C in software Self-calibration feature Simple operation Select C / F CE marked PC software included for remote RoHS compliant control and measure, logging and calibration 2 year warranty Applications Food preparation Storage facilities Educational establishments Environmental R&D Heating & ventilation setup Building & energy management Instrumentation laboratories Experimentation Refrigeration/freezer plant monitoring Museums and Galleries www.L200temperaturemonitor.co.uk www.labfacility.co.ukSpecification at an ambient temperature of 20C Input / Ranges Thermocouple to IEC 584 Type J -200C to 750C Type K -200C to1200C Type T -200C to 350C Type E -200C to 900C Type N 0C to 1300C Type R 0C to 1760C Type S 0C to 1760C Type B 300C to 1800C Pt100 to IEC751, 3 wire -200C to 850C Note: all inputs are non-isolated and sensors must be of insulated construction. Accuracy Thermocouples J K T E & N better than +/- 0.1C +/-0.1% of range -100C to span (Zero to span Type N) +/-0.15% of range -101 to -200C (J K T & E) Thermocouples R S & B better than+/-0.1C +/-0.15% of range Linearisation 0.05C Pt100 range better than 0.05C 0.1% of range Zero drift 0.01% of span per C Span drift 0.01% of span per C Display LCD, backlight Display resolution Thermocouple ranges 0.1C Pt100 range 0.01C User interface Front panel key for channel No. or auto-scan selection. PC software for all other functions. Indication Channel No., measured temperature (C or F) Reference junction Automatic, accurate reference On-board memory 512 sets of readings compensation for junction compensation is incorporated PC software Supplied as standard on CD-ROM thermocouples for thermocouple ranges Remote control & measure:- Self calibration User facility incorporated.The Log readings to file instrument auto-calibrates on every Download to PC A/D cycle * Logging, calibration Sensor open circuit Upscale indication * The integral, self-calibration facility for the thermocouple detection & indication Independent alarms should be used version is a rapid and convenient method for on-site for Process safety if required calibration and does not require any additional equipment other than the special, external link (optional). Ambient operating 0 to 50C Self-calibration of Pt100 ranges is quickly and conveniently temperature performed using plug-in precision resistors (optional). Storage temperature -20C to 70C Traceable calibration can be achieved by the user conveniently Display LCD with backlight and without recourse to a accredited Laboratory if there is Input Terminations 8 x thermocouple: mini connectors access to a certified DVM this can be used to measure the 8 x Pt100, terminal blocks L200 internally generated calibrated Voltage via the cal port presented externally to the instrument case. Considerable time PC Interface USB and cost saving are achieved by this method. Power supply 6Vdc (5.5-9.0V) via universal mains adaptor (supplied) 120-250V 50/60Hz Ordering Logging interval 5 seconds to 1 hour Thermocouple input x8 L200-TC00 Pt100 input x8 L200-PT00 Custom calibration details on application Specifications may be subject to change Standard accessories The L200 is supplied with a power supply adaptor, USB lead, PC software, and instruction manual (on CD). L200-TC includes external link. LABFACILITY LIMITED www.labfacility.co.uk SOUTHERN UK & EXPORT DIVISION: Units 5,6 & 7, Block K, Southern Cross Industrial Estate, Shripney Road, Bognor Regis, West Sussex PO22 9SE Export Sales: tel: +44(0)1243 871287 fax: +44(0)1243 871281 email: exportsales labfacility.co.uk Southern UK Sales: tel: +44(0)1243 871280 fax: +44(0)1243 871281 email: southernsales labfacility.co.uk NORTHERN UK DIVISION: Eden Place, Unit 3b Outgang Lane, Dinnington, Sheffield S25 3QT Northern UK Sales: tel: +44(0)1909 569446 fax: +44(0)1909 550632 email: northernsales labfacility.co.uk Data Ref: 050107DS/A Issue 4

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free