Product Information

AT20B420L

AT20B420L electronic component of Lem

Datasheet
CURRENT TRANSDUCER, 20A, CURRENT O/P

Manufacturer: Lem
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 126.2202 ea
Line Total: USD 126.22

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 03 May to Thu. 09 May

MOQ : 1
Multiples : 1
1 : USD 126.2202
10 : USD 98.4229

     
Manufacturer
Product Category
Brand
Sensor Output
Supply Voltage Dc Min
Supply Voltage Dc Max
Current Measuring Range Ac
Response Time
Accuracy
Product Range
Svhc
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
CKSR 25-NP electronic component of Lem CKSR 25-NP

SENSOR CURRENT FLUX 25A AC/DC
Stock : 1

CAS 50-NP electronic component of Lem CAS 50-NP

SENSOR CURRENT FLUX 50A AC/DC
Stock : 0

CKSR 50-NP electronic component of Lem CKSR 50-NP

SENSOR CURRENT FLUX 50A AC/DC
Stock : 0

AT150B420L electronic component of Lem AT150B420L

CURRENT TRANSDUCER, 150A, CURRENT O/P
Stock : 0

AT100B420L electronic component of Lem AT100B420L

CURRENT TRANSDUCER, 100A, CURRENT O/P
Stock : 0

DHR 600 C10 electronic component of Lem DHR 600 C10

Current Transducer,600A, 0-10V O/P
Stock : 0

DHR 1000 C420 electronic component of Lem DHR 1000 C420

Current Transducer,1000A, 4-20Ma O/P
Stock : 0

AT50B10 electronic component of Lem AT50B10

CURRENT TRANSDUCER, 50A, VOLTAGE O/P
Stock : 0

HAS300-S electronic component of Lem HAS300-S

Current Sensors Through Hole RoHS
Stock : 1

LAH100-P electronic component of Lem LAH100-P

Current Sensors Through Hole RoHS
Stock : 12

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

AC Current transducer AT-B420L I = 5 .. 150 A AC Current transducer AT-B420L I = 5 .. 150 A PNPN Split-core transducer for the electronic measurement of AC waveform Split-core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit (power) currents, with galvanic isolation between the primary circuit (power) and the and the secondary circuit (measurement). 4-20 mA current output secondary circuit (measurement). 4-20mA current output proportional to proportional to the RMS value of the primary current.the RMS value of the primary current. Electrical data Primary nominal current rms Output current Type Features I (A.t.Rms) I (mA) PN OUT RMS output Electrical data 5 4-20 AT 5 B420L Features Loop-powered 4-20mA current output 10 4-20 AT 10 B420L 20 4-20 AT 20 B420L Split-core type Primary nominal Output current Type RMS output 50 4-20 AT 50 B420L 16 mm sensing aperture for non- AC Current transducer AT-B420L I = 5 .. 150 A current rms 100 4-20 AT 100 B420L Loop-powered 4-20mA current PN contact measurement 150 4-20 AT 150 B420L ISp (A.t.Rms)lit-core trans ducer for the electrIonic (mA) measurement of AC waveform output PN OUT Terminal output currents, with galvanic isolation between the primary circuit (power) and the 1) 5 4-20 AT 5 B420L R Load resistance, with V = + 24 V DC < 600 W Split-core type L C Isolated plastic case recognized secondary circuit (measurement). 4-20mA current output proportional to V Supply voltage (loop-powered) + 20 .. 30 V DC 10 4-20 AT 10 B420L 16 mm sensing aperture for C the RMS value of the primary current. according to UL 94-V0. I Output current limitation < 30 mA 20 SL 4-20 AT 20 B420L non-contact measurement Overload capability - continuous 120 % of I P PN 50 4-20 AT 50 B420L Terminal output - 1 min 150 % of I Advantages PN 100 4-20 AT 100 B420L Isolated plastic case recognized 150 4-20 AT 150 B420L High isolation between primary and according to UL 94-V0. Performance data 1) secondary circuits Electrical data R Load resistance, with V = + 24 V DC < 600 W L C X Accuracy I , T = 25C (excluding offset) < 2 % of I Advantages PN A PN Primary nominal current rms Output current Type Compact case Features V Supply voltage (loop-powered) + 20 .. 30 V DC C Linearity error < 0.5 % I (A.t.Rms) I (mA) L PN OUT Cost-effective solution I Output current limitation < 30 RM S o utput mA I Electrical offset current, T = 25C 4 0.2 mA High isolation between primary SL OE A 5 4-20 AT 5 B420L Easy installation Loop-powered 4-20mA current output Overload10 t capabilityResponse - continuous4-20 time to 90% of IA Ts 1te0 pB420L 120 < % of 100 I m s r P and secondary circuits P PN 20 4-20 AT 20 B420L Split-core type BW Frequency bandwidth 50/60 Hz - 1 min 150 % of I 50 4-20 AT 50 B420L Compact case PN 16 mm sensing aperture for non- 100 4-20 AT 100 B420L Applications contact measurement Cost-effective solution 150 4-20 AT 150 B420L General data Terminal output Performance data 1) AEasy installationutomation and Supervision R Load resistance, with V = + 24 V DC < 600 W L C T Ambient operating temperature Isolated pla- st20 ic c.. as+ e 60recognCized A V Supply voltage (loop-powered) + 20 .. 30 V DC Current measurement for process C according to UL 94-V0. T Ambient storage temperature - 20 .. + 85 C I Output current limitation < 30 mA Applications S SL X Accuracy I , T = 25C (excluding offset) < 1.5 % of I regulation by distributed PLCs or PN A PN Overloamd capability -M caonstsinuous 120 % of I 90 g P PN e Linearity error < 0.5 % of I remote control (e.g. SCADA - 1 min 150 % of I Advantages L IPxx Protection degree PN IP40 PN Automation and Supervision software) I Electrical offset current, T = 25C 4 0.2 mA OE A High isolation between primary and Current measurement for process Performance data Security and Condition Monitoring t Response time to 90% of I step < 100 ms secondary circuits r PN regulation by distributed PLCs X Accuracy I , 1)T = 25C (excluding offset) < 2 % of I PN A PN Load monitoring for protection Note: Max. Load Resistance vs. Supply Voltage Compact case BW Frequency bandwidth 50/60 Hz Linearity error < 0.5 % or remote control (e.g. SCADA L Cost-effective solution systems and predictive I Electrical offset current, T = 25C 4 0.2 mA OE 35 A software) Easy installation t Response time to 90% of I step < 100 m s maintenance (e.g. conveyers, r P General data Safety and Condition BW Frequency bandwidth 50/60 Hz pumps or HVAC motors) 30 Applications Monitoring Energy management General data T Ambient operating temperature - 20 .. + 60 C A Automation and Supervision Load monitoring for protection Convenient connection to power T Ambient operating temperature - 20 .. + 60 C 25 T A Ambient storage temperature - 20 .. + 85 C Current measurement for process S systems and predictive T Ambient storage temperature - 20 .. + 85 C consumption sub-meters S regulation by distributed PLCs or m Mass 90 g m Mass 90 g maintenance (e.g. conveyers, remote control (e.g. SCADA 20 IPxx Protection degree IP40 IPxx Protection degree IP40 pumps or HVAC motors) software) Application domain Security and Condition Monitoring Energy management 15 1)1) Note: Max. Load Resistance vs. Supply Voltage Load monitoring for protection Energy and Automation Note: Max. Load Resistance vs. Supply Voltage Convenient connection to power 400 500 600 700 800 900 1000 systems and predictive 35 consumption sub-meters Max. Load Resistance (Ohm) maintenance (e.g. conveyers, Page 1/3 pumps or HVAC motors) 30 Application domain LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Energy management 071115/4 www.lem.com Convenient connection to power 25 Energy and Automation consumption sub-meters 20 Application domain 15 Energy and Automation 400 500 600 700 800 900 1000 Max. Load Resistance (Ohm) Page 1/3 Page 1/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 090609/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com 071115/4 www.lem.com Supply Voltage (V) Supply Voltage (V)Current Transducer AT-B420L Isolation characteristics 2) V Rated isolation voltage rms 300 V b with IEC 61010-1 standards and following conditions: - Reinforced isolation - Over voltage category CAT III - Pollution degree PD2 - Heterogeneous field 3) V Rms voltage for AC isolation test , 50Hz, 1min. 3.5 kV d dCp Creepage distance 6 mm dCl Clearance distance 6 mm CTI Comparative tracking index (Group I) 600 2) Notes: If insulated cable is used for the primary circuit, the voltage category could be improved according to the primary cable insulation category (please refer to the cable manufacturers indications) 3) between primary (completely filling the hole) and secondary. Safety and warning notes In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. Caution Risk of danger Ignoring the warnings can lead to serious injury and/or cause damage The electric measuring transducer may only be installed and put into operation by qualified personnel that have rceived an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety rquirements and in accordance with all the related systems and components manufacturers operating instructions. Caution Risk of electrical shock When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 2/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 090609/6 www.lem.com

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted