20A DIN Rail Type Redundancy Module DRDN20 UL62368-1 IEC62368-1 TPTC004 . 6 . 7 . % %& / - 0 * + *% 8)& 2+ * 3 >)9 2+ 5 4 : * + -1 6 6 .4 < 4 % %& ( ( * + ,-./0 ( * + -1 ( * *% )& 2+ 34 5 6 3 % %& 5 - 3 5 6 , File Name:DRDN20-SPEC 2019-08-19 20A DIN Rail Type Redundancy Module DRDN20 SPECIFICATION DRDN20- MODEL =12V, 24V, 48V NUMBER OF INPUT 2 Channels DC NORMAL VOLTAGE 12Vdc 24Vdc 48Vdc DC VOLTAGE RANGE 9~14Vdc 19~29Vdc 36~60Vdc RATED CURRENT 0~10A x2 input , 0~20A x1 input Continuous INPUT VOLTAGE DROP (Vin-Vout) (max.) 0.25V PEAK CURRENT 0~15A x2 input , 0~30A x1 input 5Sec. EFFICIENCY (Typ.) 98% INPUT REVERSE CURRENT (max.) 1mA INPUT REVERSE VOLTAGE (max.) 40Vdc 65Vdc 40Vdc RATED CURRENT 0~20A, Continuous PEAK CURRENT (max.) 30A, 5Sec. OUTPUT CAPACITANCE(Typ.) 320uF STANDBY POWER LOSSES(Typ.) 1.5W OVERLOAD <30A,5Sec. No damage PROTECTION SHORT CIRCUIT <30A,5Sec. No damage REDUNDANCY For 1+1 redundancy ,and support N+1 redundancy <18V or >31V (5%) BOTH INPUTS VOLTAGE ALARM <8.5V or >14.%7V (5 ) <34.2V or >63V (5%) FUNCTION RELAY 30Vdc/1A resistive load LED STATUS DISPLAY Green LED OK COOLING Free air convection -40 ~ +80 (Refer toDerating Curv) WORKING TEMP. Note.2 WORKING HUMIDITY 5 ~ 95% RH non-condensing STORAGE TEMP. -40 ~ +85 ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 60) VIBRATION Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes Mounting: Compliance to IEC61373 OPERATING ALTITUDE Note.3 5000 meters/OVC II IEC62368-1, UL62368-1, EAC TP TC 004 approved SAFETY STANDARDS WITHSTAND VOLTAGE IP/OP - Chassis : 0.5KVac IP/OP- Relay : 0.5KVac Relay - Chassis : 0.5KVac ISOLATION RESISTANCE IP/OP - Chassis, IP/OP- Relay, Relay - Chassis:>100M Ohms / 500Vdc / 25/ 70% RH Parameter Standard Test Level / Note Conducted EN55032(CISPR32) Class B EMC EMISSION Radiated EN55032(CISPR32) Class B ----- Voltage Flicker ----- SAFETY & Harmonic Current ----- ----- EMC (Note.4) EN55035, EN61000-6-2(EN50082-2), EN55024 Parameter Standard Test Level / Note ESD EN61000-4-2 Level 4, 15KV air Level 3, 8KV contact criteria A Radiated EN61000-4-3 Level 3, 10V/m criteria A EFT / Burst EN61000-4-4 Level 3, 2KV criteria A EMC IMMUNITY Surge EN61000-4-5 Level 3, 1KV/Line-Line Level 3, 2KV/Line-Line-Chassis criteria A Conducted EN61000-4-6 Level 3, 10V criteria A Magnetic Field EN61000-4-8 Level 4, 30A/m criteria A MTBF 611.82K hrs min. Telcordia SR-332 (Bellcore) 353.67K hrs min. MIL-HDBK-217F (25) 32*125.2*102mm (W*H*D) OTHERS DIMENSION 0.35Kg 28psc/10.8Kg/1.24CUFT PACKING - 3 % %& 5( 4 4 39 5 NOTE % ( 7 * 0,+ / 0,+ ( =0,6 > 3 5 File Name:DRDN20-SPEC 2019-08-19