40A DIN Rail Type Redundancy Module DRDN40 UL62368-1 IEC62368-1 TPTC004 % & ( ) .& * + > , .& - // * 0 1& 2 3 * 4 1 51 % * * ( ( 6 7 8 9 ( : : * 1& 6 4 4 ( * ( : 1& 2 : * .& * * +// -6 ( + - + %- 1 5 5 File Name:DRDN40-SPEC 2019-08-19 40A DIN Rail Type Redundancy Module DRDN40 SPECIFICATION DRDN40- MODEL =12V, 24V, 48V NUMBER OF INPUT 2 Channels DC NORMAL VOLTAGE 12Vdc 24Vdc 48Vdc DC VOLTAGE RANGE 9~14Vdc 19~29Vdc 36~60Vdc RATED CURRENT 0~20A x2 input , 0~40A x1 input Continuous INPUT VOLTAGE DROP (Vin-Vout) (max.) 0.3V PEAK CURRENT 0~30A x2 input , 0~60A x1 input 5Sec. EFFICIENCY (Typ.) 98% INPUT REVERSE CURRENT (max.) 1mA INPUT REVERSE VOLTAGE (max.) 40Vdc 40Vdc 65Vdc RATED CURRENT 0~40A, Continuous PEAK CURRENT (max.) 60A, 5Sec. OUTPUT CAPACITANCE(Typ.) 320uF STANDBY POWER LOSSES(Typ.) 1.5W OVERLOAD <60A,5Sec. No damage PROTECTION <60A,5Sec. No damage SHORT CIRCUIT REDUNDANCY For 1+1 redundancy ,and support N+1 redundancy BOTH INPUTS VOLTAGE ALARM <8.5V or >14.%7V (5 ) <18V or >31V (5%) <34.2V or >63V (5%) FUNCTION RELAY 30Vdc/1A resistive load LED STATUS DISPLAY Green LED OK Free air convection COOLING -40 ~ +80 (Refer toDerating Curv) WORKING TEMP. Note.2 WORKING HUMIDITY 5 ~ 95% RH non-condensing STORAGE TEMP. -40 ~ +85 ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 60) VIBRATION Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes Mounting: Compliance to IEC61373 OPERATING ALTITUDE Note.3 5000 meters/OVC II IEC62368-1, UL62368-1, EAC TP TC 004 approved SAFETY STANDARDS WITHSTAND VOLTAGE IP/OP - Chassis : 0.5KVac IP/OP- Relay : 0.5KVac Relay - Chassis : 0.5KVac ISOLATION RESISTANCE IP/OP - Chassis, IP/OP- Relay, Relay - Chassis:>100M Ohms / 500Vdc / 25/ 70% RH Parameter Standard Test Level / Note Conducted EN55032(CISPR32) Class B EMC EMISSION Radiated EN55032(CISPR32) Class B ----- ----- Voltage Flicker SAFETY & ----- EMC Harmonic Current ----- (Note.4) EN55035, EN61000-6-2(EN50082-2), EN55024 Parameter Standard Test Level / Note ESD EN61000-4-2 Level 4, 15KV air Level 3, 8KV contact criteria A Level 3, 10V/m criteria A Radiated EN61000-4-3 EFT / Burst EN61000-4-4 Level 3, 2KV criteria A EMC IMMUNITY Surge EN61000-4-5 Level 3, 1KV/Line-Line Level 3, 2KV/Line-Line-Chassis criteria A Conducted EN61000-4-6 Level 3, 10V criteria A Magnetic Field EN61000-4-8 Level 4, 30A/m criteria A MTBF 557.52K hrs min. Telcordia SR-332 (Bellcore) 277.24K hrs min. MIL-HDBK-217F (25) 55*125.2*100mm (W*H*D) OTHERS DIMENSION 0.5Kg 20psc/11Kg/1.49CUFT PACKING 6 % 4 + - : / 6 6 1 ( 6 7 8 ( 6 36 4 36/ * / * +,/ -6 NOTE 6 4 * : * * & ( 6 * & : < * 6= + ( 9 ***6 * 6 - File Name:DRDN40-SPEC 2019-08-19