3000W True Sine Wave DC-AC Inverter with Solar Charger TN-3000 series , - % && ( )*+),, % % , & & - . / . / ) / ) / ) / 0 / ) / 12 % 3 1 - 4 4 && % 5 4 . + / 12 2 +% & * 6 E13 SPECIFICATION MODEL TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248 RATED POWER (Typ.) 3000W MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles Factory setting set at 110VAC Factory setting set at 230VAC AC VOLTAGE 100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W FREQUENCY 600.1Hz 50/60Hz selectable by setting button S.W 500.1Hz 50/60Hz selectable by setting button S.W OUTPUT WAVEFORM Note.8 True sine wave (THD<3%) AC REGULATION (Typ.) 3% TRANSFER TIME (Typ.) 10ms inverter by pass SAVING MODE (Typ.) Default disabled. Load5W will be changed to standby mode FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status 24V 48V 24V 48V BAT. VOLTAGE 12V 12V VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 150A 75A DC CURRENT (Typ.) Note.4 300A 300A 150A 75A INPUT 10W standby saving mode NO LOAD DISSIPATION (Typ.) OFF MODE CURRENT DRAW (Typ.) 1mA EFFICIENCY (Typ.) Note.1 88% 90% 91% 89% 91% 92% BATTERY TYPES Open & sealed lead acid battery FUSE 40A*12 40A*6 20A*6 40A*12 40A*6 20A*6 BATTERY BAT. LOW ALARM Note.6 11.3V 22.5V 45V 11.3V 22.5V 45V INPUT 10.5V 21V 42V 10.5V 21V 42V BAT. LOW SHUTDOWN Note.6 PROTECTION REVERSE POLARITY By internal fuse open 90 5 85 5 85 5 80 5 75 5 75 5 OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover OUTPUT 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. PROTECTION OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover CIRCUIT BREAKER AC output: 40A, AC receptacle:15A AC output: 20A, AC receptacle: 15A GFCI PROCTECTION Optional (Only type F) None WORKING TEMP. Note.2 0 ~ +40 100% load 60 50% load 20% ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT o -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH STORAGE TEMP., HUMIDITY VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only for Type G ) None SAFETY STANDARDS LVD None EN60950-1 SAFETY & WITHSTAND VOLTAGE Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC EMC Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25/ 70% RH ISOLATION RESISTANCE EMC EMISSION Compliance to FCC class A Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark None Compliance to EN61000-4-2,3,4,5,6,8,11 EMC IMMUNITY CHARGE CURRENT (Typ.) 25A 12A 6A 25A 12A 6A AC CHARGER CHARGE VOLTAGE Note.6 14.3V 28.5V 57V 28.5V 57V 14.3V MAX OPEN CIRCUIT VOLTAGE 25V 45V 75V 25V 45V 75V SOLAR PANEL SHORT CIRCUIT CURRENT (max.) 30A CONTROL WIRING Note.7 RJ11 -RS232 OTHERS DIMENSION 466.8*283.5*100mm (L*W*H) PACKING 12.9Kg 1pcs/14Kg/1.98CUFT 7 8&& (7 4 7 94 ( 94 :(9 NOTE ( ) & 7 0 & ( 2 4 7(94 ( 94 <9 : 1 & % 4 (: & % & & -77(/(7( :9=7( /(( 79=7 </( <(9 6 % & % *+ & & < 4 7 4( 4:(9 File Name:TN-3000-SPEC 2015-05-273000W True Sine Wave DC-AC Inverter with Solar Charger TN-3000 series Instructions for TN-3000 monitoring software 1. The monitoring software can be downloaded from product section (with TN-3000 specification) on MEAN WELLs official website,