Slim Pressure Sensor E8EB Ideal for Workpiece Position and Original Pressure Checking The 0 to 100 kPa model can be used for workpiece position checking. The 0 to 1MPa model is ideal for original pressure check- ing. Degree of protection conforms to IEC IP54. Be sure to read Safety Precautions on page 6. Ordering Information ON/OFF output Pressure range Linear output NPN open collector PNP open collector Positive pressure 0 to 1 MPa E8EB-10C E8EB-10B Positive pressure 0 to 100 kPa E8EB-01C E8EB-01B 1 to 5 V Negative pressure 0 to 100 kPa E8EB-N0C2B E8EB-N0B2B E8EB Ratings and Specifications E8EB E8EB Item Model E8EB-10C E8EB-10B E8EB-01C E8EB-01B -N0C2B* -N0B2B* Power supply voltage 24 VDC 10% with a ripple (p-p) of 5% max. Current consumption 20 mA max. Pressure type Gauge pressure Permissible pressure 0 to 1 MPa 0 to 100 kPa 0 to 100 kPa range Pressure setting range 0 to 1 MPa 0 to 100 kPa 0 to 100 kPa Withstand pressure 2 MPa 290 kPa Applicable fluid Noncorrosive and nonflammable gases Repeat accuracy 1% FS max. (ON/OFF output) Accuracy 3% FS max. (linear output) Hysteresis 1% FS max. (linear output) Differential travel 0.4 to 1.6% FS max. (ON/OFF output) Linearity 1% FS max. (linear output) Response time 5 ms max. Linear output 1 to 5 V with an output impedance of 20 and a permissible resistive load of 10 k min. NPN open PNP open NPN open PNP open NPN open PNP open ON/OFF output collector collector collector collector collector collector Load current 80 mA max. Output applied 30 VDC max. voltage Residual NPN: 0.4 V max. (at the load current of 20 mA) and 1 V max. (at the load current of 80 mA) voltage PNP: 1.5 V max. (at the load current of 20 mA) and 2 V max. (at the load current of 80 mA) Indicator Operation indicator (red) Operating: 10C to 55C (with no icing) Ambient temperature Storage: 25C to 70C (with no icing) Ambient humidity Operating: 35% to 85% (with no condensation) 0.12% FS/C between 0C and 0.2% FS/C between 0C and 50C 50C Temperature influence 0.2% FS/C max. between 0.3% FS/C max. between 10C and 0C or 50C and 55C 10C and 0C or 50C and 55C Voltage influence 1% FS max. Insulation resistance 100 M min. (at 500 VDC) between current carry parts and case Dielectric strength 500 VAC for 1 min between current carry parts and case 2 Destruction: 10 to 500 Hz, 1.5-mm double amplitude or 100 m/s whichever is smaller, for 2 hours each in Vibration resistance X, Y, and Z directions 2 Shock resistance Destruction: 1,000 m/s 3 times each in X, Y, and Z directions Degree of protection IEC 60529 IP54 Pressure inlet Rc(PT)1/8 Connection method Pre-wired (standard cable length: 2 m) Weight (packed state) Approx. 120 g Pressure port material Zinc die-cast Accessories Instruction manual * These models are negative-pressure models.