For gas Digital Pressure Sensor DP-0 SERIES Conforming to EMC Directive Simpler and Easier to Use panasonic.net/id/pidsx/global 2015.06DP-0 Detailed setting mode Simple & Easy Operation Pressure unit setting mode Two levels of setting mode for Operation easy operation of essential RUN mode setting mode functions NO / NC The RUN mode is for threshold value setting, zero point setting mode adjustment and key lock setting / release setting, and the Response time detailed setting mode allows for basic settings for sensor Threshold value setting setting mode operation. The two-level setting mode configuration enables Zero point adjustment easy and immediate use of the product. Key lock setting / release Display color setting mode Settings initializing mode Main menu for detailed setting mode Operation setting mode* NO / NC setting mode Response time setting mode Display color setting mode Select from EASY mode, Set the comparative output Select the response time from Select the comparative output ON / hysteresis mode or window operation to NO or NC. 2.5 ms, 25 ms or 250 ms. OFF display color and the normal comparator mode. display color from red or white. * For details of operation setting mode, see page 4. Functional Design Black body for enhanced visibility of LCD display Crisp The unit body is completely black to make the LCD display easier to see. clicking feel Firm and crisp clicking feel The buttons offer firm and crisp clicking feel for smooth and reliable setting operations. 2