Product Information

ER-VAK30

ER-VAK30 electronic component of Panasonic

Datasheet
Nozzle; Works with: ER-VAJK, ER-VS02; Ø0.394x312mm

Manufacturer: Panasonic
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 50.505 ea
Line Total: USD 50.5

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

ER-VAK30
Panasonic

1 : USD 52.2031
5 : USD 46.9219
10 : USD 46.2177
25 : USD 44.3896
50 : USD 42.1281
100 : USD 41.4916
250 : USD 40.5844

0 - WHS 2


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

ER-VAK30
Panasonic

1 : USD 50.505
10 : USD 44.0773

0 - WHS 3


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

ER-VAK30
Panasonic

1 : USD 55.8453

     
Manufacturer
Product Category
Related Items
Type Of Antistatic Accessories
Body Dimensions
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
ER-VANT electronic component of Panasonic ER-VANT

Discharge Needle Unit
Stock : 0

ER-VANT2 electronic component of Panasonic ER-VANT2

DISCHARGE NEEDLE FOR REPLACEM
Stock : 0

ER-VAS electronic component of Panasonic ER-VAS

Nozzle; Works with: ER-VS02
Stock : 0

ER-VCCJ5 electronic component of Panasonic ER-VCCJ5

Cables With Connector - 0.15mm2 - 8 Core - 5m - ER-V Series.
Stock : 146

ER-VWANT electronic component of Panasonic ER-VWANT

DISCHARGE REPLACEMENT NEEDLE
Stock : 0

ER-VAK50 electronic component of Panasonic ER-VAK50

Nozzle; Works with: ER-VAJK, ER-VS02; Ø0.394x512mm
Stock : 0

ER-VS02 electronic component of Panasonic ER-VS02

High-Frequency AC Discharge Method Ultra-Compact Ionizer
Stock : 0

ER-VW electronic component of Panasonic ER-VW

ULTRA THIN IONIZER DUAL NOZZLE
Stock : 0

ER-VCCJ2 electronic component of Panasonic ER-VCCJ2

2M CABLE FOR ER-V
Stock : 0

ER-VAPS1 electronic component of Panasonic ER-VAPS1

AC ADAPTER FOR IONIZER
Stock : 0

Image Description
ER-VANT electronic component of Panasonic ER-VANT

Discharge Needle Unit
Stock : 0

ER-VANT2 electronic component of Panasonic ER-VANT2

DISCHARGE NEEDLE FOR REPLACEM
Stock : 0

ER-VAS electronic component of Panasonic ER-VAS

Nozzle; Works with: ER-VS02
Stock : 0

ER-VCCJ5 electronic component of Panasonic ER-VCCJ5

Cables With Connector - 0.15mm2 - 8 Core - 5m - ER-V Series.
Stock : 146

NC2ED-P-DC12V electronic component of Panasonic NC2ED-P-DC12V

Power Relay 12VDC 5A DPDT(25.4x11.2x27.8)mm THT
Stock : 0

NC2ED-P-DC48V electronic component of Panasonic NC2ED-P-DC48V

Power Relay 48VDC 5A DPDT(25.4x11.2x27.8)mm THT
Stock : 20

ER-VWANT electronic component of Panasonic ER-VWANT

DISCHARGE REPLACEMENT NEEDLE
Stock : 0

NC2ED-PL2-DC110V electronic component of Panasonic NC2ED-PL2-DC110V

Electromechanical Relay 110VDC 5ADC/3AAC DPDT (( 25.4mm 11.2mm 27.8mm)) THT Power Relay
Stock : 0

ER-VWCC2 electronic component of Panasonic ER-VWCC2

CABLE WITH CONNECTOR LENGTH 2
Stock : 0

ER-X016 electronic component of Panasonic ER-X016

Pulse AC Method For Faster Charge Removal
Stock : 0

High-frequency AC Method Ultra-compact Ionizer 1181 ER-VS02 General terms and conditions ............. F-3 Selection guide ........................... P.1155~ FIBER Related Information SENSORS Glossary of terms.......................... P.1591 General precautions ..................... P.1595 LASER SENSORS PHOTOELECTRIC SENSORS Certified by NRTL MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT panasonic.net/id/pidsx/global SENSORS STATIC CONTROL DEVICES LASER No. 1* in ability to accommodate a range of applications thanks to outstanding MARKERS ion balance, robust dust resistance, and an extensive nozzle selection * In-company survey PLC HUMAN MACHINE INTERFACES Optimized discharge needle tip shape for even more stable ion-producing power ENERGY MANAGEMENT The discharge needle tips spherical shape enables Previous models ER-VS02 SOLUTIONS more stable ion production while making it less likely that FA COMPONENTS the shape of the tip will change over time as a result of Spherical tip shape electrical discharge. MACHINE VISION SYSTEMS UV CURING SYSTEMS Additional protrusion Improved maintenance cycle Selection of nozzles for different applications Selection Guide Stable ion-producing performance contributes to a In addition to eight standard nozzle types, including Static Removers longer maintenance cycle, which has been improved to shower and tube nozzles, we offers a range of differently Pulse Air-gun one month or longer* in the ER-VS. shaped nozzles (including made-to-order models). *When used in an operating environment that complies with Panasonic Cleaning Box Industrial Device SUNX requirements Electrostatic Sensor Produces excellent ion balance ER-X ER-TF The adoption of high-frequency AC method allows extremely stable ion balance to be achieved. Because the ion balance is not affected by the pressure of air supplied or by the setup distance, no troublesome adjustments are ER-VS02 required after setup. ER-VW Ion balance comparison Conventional spot type using AC method Conventional bar type using DC method ER-Q Charge removal time (typical) Spot type Bar type ER-VS02 with shower nozzle ER-VS02 with bar nozzle ER-F Static 1,000 100 500 voltage (V) 50 0 100 50 100 150 200 300 0 300 3.937 1.969 7.874 11.811 11.811 5.906 Time 50 0 1 2 3 4 (sec.) 100 500 Distance to object (mm in) Distance from center of effective charge removal length (mm in) * Comparison test carried out by Panasonic Industrial devices SUNX * Comparison test carried out by Panasonic Industrial devices SUNX Ion balance (V) Ion balance (V) Ultra-compact Ionizer ER-VS02 1182 APPLICATIONS FIBER SENSORS LASER Charge removal and dust removal Pinpoint charge removal of Removal of dust from connec- SENSORS of relay and switch contacts electronic components tors and switches PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Ultra-compact design accurately removes charges of objects even from narrow spaces SENSOR OPTIONS The main unit is merely SIMPLE 109 27 28 mm 4.291 WIRE-SAVING 27 mm UNITS 1.063 1.102 in, so it 1.063 in can easily be combined WIRE-SAVING SYSTEMS with other devices and 28 mm also be installed as an MEASUREMENT 1.102 in SENSORS add-on. Furthermore, the STATIC high-voltage power supply It can be installed in places where CONTROL is built-in, so no extra the conventional bar type cannot, DEVICES so it can be placed closer to the space is required except LASER object for more accurate charge for the ionizer itself. MARKERS removal. PLC BASIC PERFORMANCE / MAINTENANCE HUMAN MACHINE INTERFACES ENERGY Completely safe design and easy maintenance MANAGEMENT SOLUTIONS Easy discharge needle maintenance Low power consumption and low-voltage wiring FA COMPONENTS The power supply voltage is 24 V DC, and the power The discharge needle can be removed from the rear of consumed is only 70 mA or less. the main unit, so there is no need to remove the nozzle MACHINE VISION In addition, safety is enhanced because no high-voltage SYSTEMS when replacing the needle. Maintenance is easy even cables are required. when the ion air outlet is located close to the object. UV CURING SYSTEMS Discharge needle is covered by the nozzle The discharge needle does not protrude from the main unit, so it cannot be touched by accident. Furthermore, no leaks can occur when it is brought close to metallic Selection objects. Guide Static Removers Safe design Pulse Air-gun A checking function and an abnormal discharge Cleaning Box monitoring function are provided to notify the operator Electrostatic when it is time to clean or replace the discharge needle Sensor and to prevent discharge problems from occurring. Each function has an LED display to use for checking. The ER-X output from each function can also be used to externally monitor the status of the ionizer during operation. ER-TF Shower nozzle ER-VS02 ER-VW ER-Q ER-F Lights up when the Lights up when abnormal discharge needle is discharge is detected worn or dirty (Red LED) (Orange LED) Abnormal discharge Checking function monitoring function When lit, the When lit, an abnormal discharge needle discharge has been may be worn or dirty. detected, e.g. due to a foreign substance, and discharge halted in order to maintain safety. 111.6 mm 4.394 in (With shower nozzle attached) 109 mm 4.291 in (Main unit only)

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted