ELECTRICAL SOLUTIONS A. System Overview Flex Conductor, Two-Hole, Standard Barrel with Window Lug, 45 Angle For Use with Flexible, Extra-Flexible, and Code Stranded Copper Conductors B1. Cable Ties Type LCDX-H Can be used with code conductor and flex conductor class: G, H, I, Tin-plated to inhibit corrosion K, M and Diesel Locomotive UL Listed and CSA Certified to 35 KV** and temperature rated to B2. Generously beveled wire entry prevents bent back strands when 90C when crimped with Panduit and specified competitor Cable Accessories inserting conductor into barrel crimping tools and dies Color-coded barrels marked with Panduit and specified competitor American Bureau of Shipping approved die index numbers for proper crimp die selection Available with NEMA hole sizes and spacing B3. Stainless Inspection window to visually assure full conductor insertion Steel Ties W C1. Wiring HOLE Duct SPACING C2. B Surface Raceway INSPECTION WINDOW 45 T C3. Abrasion L Protection Figure Dimensions Stud Stud Panduit Burndy T&B Wire Flex Conductor Size (In.) Code Hole Hole Panduit Die Die Die Strip Std. C4. Class Diesel Conductor Size Spacing Color Index Index Index Length Pkg. Cable Part Number G, H, I, K, M Locomotive Size (In.) (In.) W B T L Code No. No. No. (In.) Qty. Management LCDX8-10AH-L 10 .63 .41 .42 .08 1.63 Red P21 49 21 1/2 50 LCDX8-14AH-L 1/4 .63 .48 .42 .07 1.71 Red P21 49 21 1/2 50 D1. LCDX8-14BH-L 1/4 .75 .48 .42 .07 1.84 Red P21 49 21 1/2 50 8 AWG 8 AWG 8 AWG Terminals LCDX8-14DH-L 1/4 1.00 .48 .42 .07 2.09 Red P21 49 21 1/2 50 LCDX8-38DH-L 3/8 1.00 .60 .42 .05 2.30 Red P21 49 21 1/2 50 LCDX6-10AH-L 10 .63 .46 .48 .08 1.68 Blue P24 7 24 9/16 50 D2. LCDX6-10BH-L 10 .75 .46 .48 .08 1.81 Blue P24 7 24 9/16 50 Power Connectors LCDX6-10GH-L 10 1.50 .46 .48 .08 2.56 Blue P24 7 24 9/16 50 LCDX6-10PH-L 10 .69 .46 .48 .08 1.74 Blue P24 7 24 9/16 50 LCDX6-14AH-L 1/4 .63 .48 .48 .08 1.77 Blue P24 7 24 9/16 50 6 AWG 6 AWG 6 AWG D3. Grounding LCDX6-14BH-L 1/4 .75 .48 .48 .08 1.89 Blue P24 7 24 9/16 50 Connectors LCDX6-14DH-L 1/4 1.00 .48 .48 .08 2.14 Blue P24 7 24 9/16 50 LCDX6-56DH-L 5/16 1.00 .56 .48 .07 2.26 Blue P24 7 24 9/16 50 E1. LCDX6-38DH-L 3/8 1.00 .62 .48 .06 2.35 Blue P24 7 24 9/16 50 Labeling LCDX4-14AH-L 1/4 .63 .55 .53 .09 1.83 Gray P29 8 29 5/8 50 Systems LCDX4-14BH-L 1/4 .75 .55 .53 .09 1.96 Gray P29 8 29 5/8 50 5, 4, 3 LCDX4-14DH-L 1/4 1.00 .55 .53 .09 2.21 Gray P29 8 29 5/8 50 4 AWG 4 AWG AWG LCDX4-56DH-L 5/16 1.00 .55 .53 .09 2.33 Gray P29 8 29 5/8 50 E2. Labels LCDX4-38DH-L 3/8 1.00 .62 .53 .08 2.42 Gray P29 8 29 5/8 50 LCDX2-14AH-E* 1/4 .63 .70 .59 .11 1.92 Brown P33 10 33 11/16 20 LCDX2-14BH-E* 1/4 .75 .70 .59 .11 2.04 Brown P33 10 33 11/16 20 E3. Pre-Printed LCDX2-14DH-E* 1/4 1.00 .70 .59 .11 2.29 Brown P33 10 33 11/16 20 2 AWG 2 AWG 2 AWG & Write-On LCDX2-56DH-E* 5/16 1.00 .70 .59 .11 2.42 Brown P33 10 33 11/16 20 Markers LCDX2-38DH-E* 3/8 1.00 .70 .59 .11 2.49 Brown P33 10 33 11/16 20 LCDX2-12H-E* 1/2 1.75 .75 .59 .09 3.66 Brown P33 10 33 11/16 20 E4. LCDX1-14AH-X 1/4 .63 .76 .66 .12 2.06 Green P37 11 37 3/4 10 Permanent Identification LCDX1-14BH-X 1/4 .75 .76 .66 .12 2.18 Green P37 11 37 3/4 10 LCDX1-14DH-X 1/4 1.00 .76 .66 .12 2.43 Green P37 11 37 3/4 10 E5. 1 AWG 1 AWG 1 AWG LCDX1-56DH-X 5/16 1.00 .76 .66 .12 2.49 Green P37 11 37 3/4 10 Lockout/ Tagout LCDX1-38DH-X 3/8 1.00 .76 .66 .12 2.56 Green P37 11 37 3/4 10 & Safety LCDX1-12H-X 1/2 1.75 .80 .66 .12 3.73 Green P37 11 37 3/4 10 Solutions See pages D3.70 D3.73 for tool and die information. *Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools. F. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. Index NEMA hole sizes and spacing. Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.ELECTRICAL SOLUTIONS A. System Overview Flex Conductor, Two-Hole, Standard Barrel with Window Lug, 45 Angle (continued) B1. Cable Ties Figure Dimensions Stud Stud Panduit Burndy T&B Wire Flex Conductor Size (In.) Code Hole Hole Panduit Die Die Die Strip Std. B2. Class Diesel Conductor Size Spacing Color Index Index Index Length Pkg. Cable Part Number G, H, I, K, M Locomotive Size (In.) (In.) W B T L Code No. No. No. (In.) Qty. Accessories LCDX1/0-14AH-X 1/4 .63 .85 .72 .13 2.21 Pink P42 12 42 3/4 10 LCDX1/0-14BH-X 1/4 .75 .85 .72 .13 2.33 Pink P42 12 42 3/4 10 B3. LCDX1/0-56BH-X 5/16 .75 .85 .72 .13 2.33 Pink P42 12 42 3/4 10 Stainless LCDX1/0-56DH-X 5/16 1.00 .85 .72 .13 2.58 Pink P42 12 42 3/4 10 1/0 AWG 1/0 AWG 1/0 AWG Steel Ties LCDX1/0-38DH-X 3/8 1.00 .85 .72 .13 2.64 Pink P42 12 42 3/4 10 LCDX1/0-12DH-X 1/2 1.00 .85 .72 .13 2.89 Pink P42 12 42 3/4 10 C1. LCDX1/0-12H-X 1/2 1.75 .85 .72 .13 3.81 Pink P42 12 42 3/4 10 Wiring LCDX2/0-14AH-X 1/4 .63 .96 .83 .13 2.30 Black P45 13 45 7/8 10 Duct LCDX2/0-14BH-X 1/4 .75 .96 .83 .13 2.43 Black P45 13 45 7/8 10 LCDX2/0-56DH-X 5/16 1.00 .96 .83 .13 2.68 Black P45 13 45 7/8 10 C2. 2/0 AWG 2/0 AWG 2/0 AWG LCDX2/0-38DH-X 3/8 1.00 .96 .83 .13 2.74 Black P45 13 45 7/8 10 Surface LCDX2/0-12DH-X Raceway 1/2 1.00 .96 .83 .13 3.03 Black P45 13 45 7/8 10 LCDX2/0-12H-X 1/2 1.75 .96 .83 .13 3.90 Black P45 13 45 7/8 10 LCDX3/0-14AH-X 1/4 .63 1.06 .91 .14 2.39 Orange P50 14 50 1 10 C3. LCDX3/0-56DH-X 5/16 1.00 1.06 .91 .14 2.78 Orange P50 14 50 1 10 Abrasion 3/0 AWG 3/0 AWG 3/0 AWG Protection LCDX3/0-38DH-X 3/8 1.00 1.06 .91 .14 2.85 Orange P50 14 50 1 10 LCDX3/0-12H-X 1/2 1.75 1.06 .91 .14 3.99 Orange P50 14 50 1 10 LCDX4/0-14AH-X 1/4 .63 1.19 1.03 .16 2.67 Purple P54 15 54 1 1/16 10 C4. Cable LCDX4/0-14BH-X 1/4 .75 1.19 1.03 .16 2.79 Purple P54 15 54 1 1/16 10 Management LCDX4/0-56DH-X 5/16 1.00 1.19 1.03 .16 3.04 Purple P54 15 54 1 1/16 10 LCDX4/0-38DH-X 3/8 1.00 1.19 1.03 .16 3.07 Purple P54 15 54 1 1/16 10 4/0 AWG 4/0 AWG 4/0 AWG LCDX4/0-12DH-X 1/2 1.00 1.19 1.03 .16 3.36 Purple P54 15 54 1 1/16 10 D1. LCDX4/0-12EH-X Terminals 1/2 1.25 1.19 1.03 .16 3.62 Purple P54 15 54 1 1/16 10 LCDX4/0-12H-X 1/2 1.75 1.19 1.03 .16 4.25 Purple P54 15 54 1 1/16 10 LCDX250-38DH-X 3/8 1.00 1.28 1.03 .17 3.11 Yellow P62 16 62 1 1/16 10 D2. LCDX250-38H-X 3/8 1.75 1.28 1.03 .17 3.86 Yellow P62 16 62 1 1/16 10 Power 250 kcmil 262.6 kcmil LCDX250-12EH-X 1/2 1.25 1.28 1.03 .17 3.66 Yellow P62 16 62 1 1/16 10 Connectors LCDX250-12H-X 1/2 1.75 1.28 1.03 .17 4.29 Yellow P62 16 62 1 1/16 10 LCDX300-38DH-6 3/8 1.00 1.39 1.19 .18 3.29 Red P71 18 71H 1 1/4 6 D3. 300 kcmil 313.1 kcmil LCDX300-12H-6 1/2 1.75 1.39 1.19 .18 4.47 Red P71 18 71H 1 1/4 6 Grounding LCDX350-56DH-6 Connectors 5/16 1.00 1.54 1.29 .22 3.40 Blue P76 19 76H 1 3/8 6 LCDX350-38DH-6 3/8 1.00 1.54 1.29 .22 3.43 Blue P76 19 76H 1 3/8 6 LCDX350-38H-6 3/8 1.75 1.54 1.29 .22 4.18 Blue P76 19 76H 1 3/8 6 350 kcmil 373.7 kcmil E1. LCDX350-12EH-6 1/2 1.25 1.54 1.29 .22 3.98 Blue P76 19 76H 1 3/8 6 Labeling Systems LCDX350-12H-6 1/2 1.75 1.54 1.29 .22 4.61 Blue P76 19 76H 1 3/8 6 LCDX450-38DH-6 3/8 1.00 1.70 1.40 .26 3.75 Brown P87 20 87H 1 7/16 6 450 kcmil 444.4 kcmil LCDX450-12H-6 1/2 1.75 1.70 1.40 .26 4.74 Brown P87 20 87H 1 7/16 6 E2. LCDX500-56DH-6 5/16 1.00 1.89 1.48 .26 3.70 Pink P99 L99 99H 1 9/16 6 Labels LCDX500-38DH-6 3/8 1.00 1.89 1.48 .26 3.73 Pink P99 L99 99H 1 9/16 6 500 kcmil 535.3 kcmil LCDX500-12EH-6 1/2 1.25 1.89 1.48 .26 4.41 Pink P99 L99 99H 1 9/16 6 E3. LCDX500-12H-6 1/2 1.75 1.89 1.48 .26 4.91 Pink P99 L99 99H 1 9/16 6 Pre-Printed LCDX600-12H-6 600 kcmil 1/2 1.75 1.89 1.48 .26 4.91 Pink P99 400 99H 1 9/16 6 & Write-On Markers LCDX650-38DH-6 3/8 1.00 1.95 1.45 .30 3.74 Black P106 24 106H 1 1/2 6 646.4 kcmil LCDX650-12H-6 1/2 1.75 1.95 1.45 .30 4.92 Black P106 24 106H 1 1/2 6 E4. LCDX750-38DH-3 3/8 1.00 2.17 1.66 .32 4.21 Yellow P115 L115 115H 1 3/4 3 Permanent LCDX750-12EH-3 1/2 1.25 2.17 1.66 .32 4.65 Yellow P115 L115 115H 1 3/4 3 Identification LCDX750-12GH-3 1/2 1.50 2.17 1.66 .32 4.90 Yellow P115 L115 115H 1 3/4 3 777.7 kcmil E5. LCDX750-12H-3 1/2 1.75 2.17 1.66 .32 5.15 Yellow P115 L115 115H 1 3/4 3 Lockout/ LCDX750-58GH-3 5/8 1.50 2.17 1.66 .32 4.90 Yellow P115 L115 115H 1 3/4 3 Tagout & Safety See pages D3.70 D3.73 for tool and die information. Solutions *Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. F. NEMA hole sizes and spacing. Index For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)