Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input A high level of operational safety in complex global networks Reliable startup of heavy loads due to POWER BOOST The reliability of a power supply unit determines the availability of individual components in a system and whether complex systems can function safely. The globalization of markets increases the demands placed on the power supply unit. A wide-range input and a high level of availability are required. These requirements are met by MINI POWER. 1. Short Description MINI POWER is the extra narrow power supply unit, which is available in widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.). In addition to a 24 V version with output currents of 1 A, 2 A, and 4 A, special voltages are also available with 5 V/3 A, +/-15 V/1 A, and 10 - 15 V/2 A for 2. Area of Application connection to single-phase AC networks or to two external conductors in three-phase networks with nominal voltages of 100 - 240 V AC. MINI POWER can be used globally due to the Two DC/DC converters convert low direct voltages consistent provision of a wide-range input. into an adjustable and regulated 24 V output voltage. In this way, your entire system can be tested at any With the DIN rail bus connector, the MINI-SYS-PS production location in the world and can be delivered to can be connected in parallel to supply other modules in any location in the world without faulty switching of the the same system with a regulated 24 V DC voltage. input voltage. This reduces storage costs and logistical Reliable startup of heavy loads is ensured by a effort. power reserve of up to 100% the POWER BOOST. An international approval package including The high level of operational safety is also ensured in UL 60950 for IT equipment and UL 508 for industrial complex global networks. MINI POWER also operates control equipment enables the device to be used in applications where static voltage dips, transient globally. power supply failures or phase failure are common. Powerful capacitors ensure mains buffering of more than 20 ms at full load. Headquarters: Phoenix Contact GmbH & Co. KG Flachsmarktstrae 8 32825 Blomberg Germany Phone +49 - 52 35 - 30 0 Fax +49 - 52 35 - 34 12 00 www.phoenixcontact.com Local Contact: www.phoenixcontact.com/salesnetwork Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 3. Technical Data 114.5 (4.508 in.) 22.5 mm (0.886 in.) MINI-PS-12-24DC/24DC/1 DC/DC Converter U u 7 mm (0.28 in.) Solid Stranded Torque 2 mm AWG Nm Ib in Input 0.2 - 2.5 0.2 - 2.5 25 - 14 0.5 - 0.6 4.4 - 5.3 Output 0.2 - 2.5 0.2 - 2.5 25 - 14 0.5 - 0.6 4.4 - 5.3 Signal 0.2 - 2.5 0.2 - 2.5 25 - 14 0.5 - 0.6 4.4 - 5.3 Pcs. Description Type Order No. Pkt. Power supply unit, primary switched, narrow design MINI-PS-12-24DC/24DC/1 28 66 28 4 1 Technical Data Input Data 1 Nominal input voltage 12 - 24 V DC (wide-range input) Input voltage range (current consumption) 10 - 32 V DC Current consumption (for nominal values) 2.6 A (12 V DC)/1.3 A (24 V DC), approximately Inrush current limiting < 15 A, typical Mains buffering for a nominal load (typical) > 3 ms (12 V DC)/> 20 ms (24 V DC) Switch-on time after applying the mains voltage < 0.5 s Transient surge protection Varistor Input fuse, internal 6.3 A (device protection) Output Data 2 Nominal output voltage U /tolerance 24 V DC/1% N Setting range for the output voltage 22.5 - 28.5 V DC Output current during convection cooling and nominal values Nominal output current I -25C to +60C (-13F to +140F) N 1 A (U = 24 V) OUT Derating Short-circuit current limit From +60C (+140F), 2.5% per Kelvin Startup of capacitive loads 4 A, approximately System deviation on: Static load change 10 - 90% Unlimited Dynamic load change 10 - 90% < 1%, typical Input voltage change 10% < 3%, typical Maximum power dissipation No load/nominal load < 0.1%, typical Level of efciency (typical) 2.5 W/7.5 W Response time U (10% - 90%) > 78% (at 24 V DC and at nominal values) OUT Residual ripple/switching peaks (20 MHz) < 30 ms, typical Can be connected in parallel < 100 mV (for nominal values) pp Internal surge protection To increase redundancy and power Resistance to return supply Yes, limited to 35 V DC, approximately 35 V DC Signal Output Data DC OK (active) (U > 21.5 V DC = high signal) +24 V signal/20 mA, maximum out LED (U > 21.5 V DC = LED permanently on) Green LED out PHOENIX CONTACT page 2 of 8 99 mm (3.898 in.)