Dual output from a single input rail Features 1kVDC or 2kVDC input/output basic isolation 1kVDC output/output isolation DC/DC Converter Power sharing on outputs Unregulated Optional continuous short circuit protected No external components required Converters RUZ Efficiency up to 85% Description 2 Watt The RUZ DC/DC converter offers two independent isolated outputs. Typical applications include SIP7 multiple channel circuits where inter-channel isolation is also required. The /H option offers 2kVDC isolation between input and outputs. The /P option is with continuous short circuit protection on either or both outputs. Isolated Dual Output Selection Guide Part nom. Input Output Output Output Efficiency max. Capacitive (1) (2) Number Voltage Voltage V1 Voltage V2 Current typ. Load VDC VDC VDC mA % F (3,4) RUZ-050505 5 5 5 200/200 70-82 470/470 Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the capacitive load that will allow start up in under 1s without damage to the converter Model Numbering RUZ- / IEC60950-1 certified (3) EN60950-1 certified Protection nom. Input Voltage (4) Isolation Option Output Voltage Notes: Note3: standard part is without Continuous Short Circuit Protection add suffix /P for Continuous Short Circuit Protection Note4: add suffix /H for 2kVDC Isolation or add suffix /HP for 2kVDC Isolation and Continuous Short Circuit Protection Ordering Examples: RUZ-050505/P= 5V Input Voltage, 5V Output Voltage (V1), 5V Output Voltage (V2) with continuous short circuit protection RUZ-122424/HP= 12V Input Voltage, 24V Output Voltage (V1), 24V Output Voltage (V2) with 2kVDC isolation and continuous short circuit protection www.recom-power.com REV.: 1/2018 ECO-1RUZ DC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin and full load unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Range 10% (5) Minimum Load 0% Internal Operating Frequency 20kHz 50kHz 85kHz Output Ripple and Noise 20MHz BW 150mVp-p Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met Efficiency vs. Load 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Output Load % REGULATIONS Parameter Condition Value Output Accuracy 5.0% max. Line Regulation low line to high line 1.2% of 1.0% Vin typ. Load Regulation 10% to 100% load 15.0% max. Deviation vs. Load 25 20 15 10 5 0 -50 -10 0 10 20 30 40 50 60 70 80 90 100 Output Load % continued on next page www.recom-power.com REV.: 1/2018 ECO-2 Deviation % Efficiency %