DC Fan 40 40 20 mm San Ace 40 9P type General Specifications Material Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) At 1 m away from the air inlet Storage temperature -30 to +70C (Non-condensing) Sensor Lead wire Red Black or Blue Yellow Mass 45 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V V A W min m/min CFM Pa inchH O dB (A) C h 109P0405J601 0.46 2.3 9800 0.28 9.9 98.5 0.396 39 40000/60C 109P0405H601 0.32 1.6 8000 0.225 8.0 65.7 0.264 33 5 4.5 to 5.5 -20 to +70 109P0405F601 0.25 1.25 6500 0.183 6.5 45.1 0.181 28 60000/60C 109P0405M601 0.12 0.6 5000 0.136 4.8 26.5 0.106 24 109P0412G601 0.28 3.36 12500 0.35 12.4 153.8 0.618 44 40000/60C -20 to +60 109P0412D601 0.18 2.16 11000 0.31 10.9 124 0.498 42 109P0412E601 7 to 13.8 0.13 1.56 9200 0.26 9.2 87.3 0.351 37 12 109P0412H601 60000/60C 0.11 1.32 8000 0.225 8.0 65.7 0.264 33 -20 to +70 109P0412F601 0.09 1.08 6500 0.183 6.5 45.1 0.181 28 109P0412M601 8 to 13.8 0.06 0.72 5000 0.136 4.8 26.5 0.106 24 109P0424G601 12 to 27.6 0.15 3.6 12500 0.35 12.4 153.8 0.618 44 -20 to +60 40000/60C 109P0424D601 12 to 27.6 0.13 3.12 11000 0.31 10.9 124 0.498 42 109P0424H601 24 12 to 27.6 0.07 1.68 8300 0.233 8.2 69.6 0.28 35 109P0424F601 14 to 27.6 0.06 1.44 6500 0.183 6.5 45.1 0.181 28 -20 to +70 60000/60C 109P0424B601 20.4 to 27.6 0.06 1.44 5200 0.14 4.9 28.3 0.114 25 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on pp. 562 to 563. Lock sensor Airflow - Static Pressure Characteristics 109P0405J601 With pulse sensor 109P0405H601 With pulse sensor 109P0405F601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) 2 (inch H O) (Pa) (inch H2O) (Pa) 0.25 130 90 60 0.35 0.50 120 80 0.45 110 5.5 V 0.30 0.20 100 70 0.40 5.5 V 5 V 90 5.5 V 0.25 0.35 60 40 80 0.15 5 V 0.30 5 V 4.5 V 0.20 50 70 4.5 V 0.25 60 40 4.5 V 0.15 0.10 50 0.20 30 20 40 0.15 0.10 30 20 0.05 0.10 20 0.05 10 0.05 10 0 0 0 0 0 0 0 3 3 3 0.1 0.2 0.3 0.4 (m /min) 0.1 0.2 0.3 (m /min) (m /min) 0.1 0.2 0.3 0 2 4 6 8 10 12 14 (CFM) 0 2 4 6 8 10 (CFM) 0 2 4 6 8 10 (CFM) Airflow Airflow Airflow 30 Static pressure Static pressure Static pressure Airflow - Static Pressure Characteristics 109P0405M601 With pulse sensor 109P0412G601 With pulse sensor 109P0412D601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 0.9 0.200 50 220 180 0.7 0.8 200 160 0.175 0.6 13.8 V 180 40 0.7 140 13.8 V 0.150 12 V 160 0.5 0.6 12 V 120 140 0.125 30 0.5 5.5 V 0.4 100 120 7 V 7 V 0.100 5 V 0.4 100 80 0.3 20 0.075 4.5 V 80 0.3 60 0.2 60 0.050 0.2 40 10 40 0.1 0.025 0.1 20 20 0 0 0 0 0 0 3 3 3 0.05 0.10 0.15 0.20 (m /min) 0.1 0.2 0.3 0.4 0.5 (m /min) 0.1 0.2 0.3 0.4 (m /min) 0 1 2 3 4 5 6 7 (CFM) 0 2 4 6 8 10 12 14 16 18 (CFM) 0 2 4 6 8 10 12 14 (CFM) Airflow Airflow Airflow 109P0412E601 With pulse sensor 109P0412H601 With pulse sensor 109P0412F601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 0.25 0.5 100 60 120 0.4 13.8 V 100 0.20 13.8 V 0.4 80 13.8 V 12 V 0.3 12 V 80 40 0.3 0.15 60 12 V 7 V 60 0.2 7 V 0.2 0.10 40 40 20 7 V 0.1 0.1 0.05 20 20 0 0 0 0 0 0 3 3 3 (m /min) (m /min) (m /min) 0.1 0.2 0.3 0.1 0.2 0.3 0.1 0.2 0.3 (CFM) (CFM) (CFM) 0 2 4 6 8 10 0 2 4 6 8 10 0 2 4 6 8 10 Airflow Airflow Airflow 109P0412M601 With pulse sensor 109P0424G601 With pulse sensor 109P0424D601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 0.7 40 200 160 0.8 0.150 0.6 27.6 V 180 140 0.7 24 V 13.8 V 160 0.5 0.125 30 0.6 120 140 12 V 12 V 0.4 100 0.100 0.5 120 27.6 V 20 0.4 100 80 0.075 0.3 8 V 80 0.3 60 24 V 0.050 0.2 60 10 40 0.2 12 V 40 0.025 0.1 0.1 20 20 0 0 0 0 0 0 3 0 3 3 (m /min) 0.1 0.2 0.3 0.4 (m /min) (m /min) 0.05 0.10 0.15 0.20 0.1 0.2 0.3 0.4 0 2 4 6 8 10 12 14 (CFM) (CFM) (CFM) 0 1 2 3 4 5 6 7 0 2 4 6 8 10 12 14 Airflow Airflow Airflow 109P0424H601 With pulse sensor 109P0424F601 With pulse sensor 109P0424B601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 0.25 0.4 100 60 40 0.15 0.20 27.6 V 80 0.3 27.6 V 30 24 V 40 27.6 V 24 V 0.15 0.10 60 0.2 20 24 V 12 V 14 V 0.10 40 20 0.05 20.4 V 0.1 10 0.05 20 0 0 0 0 0 0 0 3 3 3 0.1 0.2 0.3 (m /min) 0.1 0.2 0.3 (m /min) 0.05 0.10 0.15 0.20 (m /min) (CFM) 0 2 4 6 8 10 (CFM) 0 2 4 6 8 10 (CFM) 0 1 2 3 4 5 6 7 Airflow Airflow Airflow 31 Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure DC Fan 40 mm sq. DC