DC Fan 80 80 20 mm San Ace 80 9P type General Specifications Material Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) At 1 m away from the air inlet Storage temperature -30 to +70C (Non-condensing) Sensor Lead wire Red Black or Blue Yellow Mass 100 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V V A W min m/min CFM Pa inchH O dB (A) C h 109P0812C601 0.29 3.48 3700 1.07 37.8 46 0.185 39 -20 to +60 109P0812H601 12 10.2 to 13.8 0.21 2.52 2900 0.84 29.7 29.4 0.118 31 109P0812M601 0.13 1.56 2300 0.67 23.7 18.6 0.075 25 60000/60C -20 to +70 109P0824H601 0.12 2.88 2900 0.84 29.7 29.4 0.118 31 24 20.4 to 27.6 109P0824M601 0.07 1.68 2300 0.67 23.7 18.6 0.075 25 109P0848C601 0.08 3.84 3700 1.07 37.8 46 0.185 39 -20 to +70 48 38 to 57.6 40000/60C 109P0848H601 0.05 2.4 2900 0.84 29.7 29.4 0.118 31 -20 to +60 The following sensor and control options are available for selection. Available for all models. Lock sensor Differs according to the model. Refer to the table on p. 563. Without sensor Airflow - Static Pressure Characteristics 109P0812C601 With pulse sensor 109P0812H601 With pulse sensor 109P0812M601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 70 0.16 40 0.12 30 0.25 0.14 60 13.8 V 0.10 13.8 V 13.8 V 30 0.12 0.20 50 12 V 0.08 20 12 V 0.10 10.2 V 40 12 V 0.15 0.08 20 0.06 30 10.2 V 10.2 V 0.06 0.10 0.04 10 20 10 0.04 0.05 0.02 10 0.02 0 0 0 0 0 0 3 3 3 (m /min) 0.5 1.0 1.5 0.5 1.0 (m /min) 0.5 1.0 (m /min) (CFM) 0 10 20 30 40 50 0 10 20 30 40 (CFM) 0 10 20 30 40 (CFM) Airflow Airflow Airflow 105 Static pressure Static pressure Static pressure DC Fan 80 mm sq. DC Airflow - Static Pressure Characteristics 109P0824H601 With pulse sensor 109P0824M601 With pulse sensor 109P0848C601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 0.30 0.16 40 0.12 30 70 0.25 0.14 27.6 V 60 0.10 27.6 V 57.6 V 30 0.12 0.20 50 24 V 0.08 20 48 V 0.10 20.4 V 40 24 V 0.15 0.08 20 0.06 38 V 20.4 V 30 0.06 0.10 0.04 10 20 10 0.04 0.05 0.02 10 0.02 0 0 0 0 0 0 3 3 3 0.5 1.0 (m /min) 0.5 1.0 (m /min) 0.5 1.0 1.5 (m /min) 0 10 20 30 40 (CFM) 0 10 20 30 40 (CFM) 0 10 20 30 40 50 60 (CFM) Airflow Airflow Airflow 109P0848H601 With pulse sensor Operating voltage range (inch H2O) (Pa) 0.18 0.16 40 57.6 V 0.14 30 0.12 48 V 0.10 0.08 20 38 V 0.06 0.04 10 0.02 0 0 3 0.5 1.0 1.5 (m /min) (CFM) 0 10 20 30 40 50 Airflow Dimensions (unit: mm) 0 800.5 20 -1 4-4.30.3 71.50.3 Mounting hole (3.5) (3.5) Lead wire AWG24 UL 1007 Rotating direction Airflow direction 106 +30 300 0 (10) Static pressure 800.5 Static pressure 71.50.3 Static pressure Static pressure