DC Fan 60 60 25 mm San Ace 60 9R type General Specifications Material Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) At 1 m away from the air inlet Storage temperature -30 to +70C (Non-condensing) Sensor Lead wire Red Black or Blue Yellow Mass 90 g Specifications The models listed below have ribs and pulse sensors. For models without ribs, append1 to the end of model numbers. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V V A W min m/min CFM Pa inchH O dB (A) C h 109R0605H401 0.34 1.7 3800 0.53 18.7 40.2 0.161 28 -20 to +70 109R0605F401 5 4.5 to 5.5 0.2 1.0 3200 0.44 15.5 29.4 0.118 24 -20 to +60 60000/60C 109R0605M401 0.13 0.65 2600 0.36 12.7 19.6 0.079 20 -20 to +70 109R0612J401 0.47 5.64 7600 1.06 37.1 155.0 0.622 44 -20 to +60 40000/60C 10.8 to 13.2 109R0612G401 0.24 2.88 5600 0.78 27.5 87.3 0.351 39 109R0612D401 10.2 to 13.8 0.21 2.52 5150 0.72 25.4 73.5 0.295 37 109R0612S401 12 0.17 2.04 4600 0.65 23.0 56.8 0.228 33 -20 to +70 60000/60C 109R0612H401 6 to 13.8 0.11 1.32 3800 0.53 18.7 40.1 0.161 28 109R0612F401 0.09 1.08 3200 0.44 15.5 29.4 0.118 24 109R0612M401 7 to 13.8 0.06 0.72 2600 0.36 12.7 19.6 0.079 20 109R0624J401 21.6 to 26.4 0.24 5.76 7600 1.06 37.1 155.0 0.622 44 -20 to +60 109R0624G401 20.4 to 27.6 0.13 3.12 5600 0.78 27.5 87.3 0.351 39 40000/60C 109R0624D401 0.12 2.88 5150 0.72 25.4 73.5 0.295 37 109R0624S401 24 0.08 1.92 4600 0.65 23.0 56.8 0.228 33 -20 to +70 12 to 27.6 109R0624H401 0.06 1.44 3800 0.53 18.7 40.2 0.161 28 60000/60C 109R0624F401 0.05 1.2 3200 0.44 15.5 29.4 0.118 24 109R0624M401 14 to 27.6 0.04 0.96 2600 0.36 12.7 19.6 0.079 20 109R0648J401 43.2 to 52.8 0.12 5.76 7600 1.06 37.1 155.0 0.622 44 -20 to +60 40000/60C 109R0648G401 48 43 to 53 0.07 3.36 5600 0.78 27.5 87.3 0.351 39 109R0648H401 40 to 53 0.04 1.92 3800 0.53 18.7 40.2 0.161 28 -20 to +70 60000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 564. Lock sensor PWM control 74 Airflow - Static Pressure Characteristics 109R0605H401 With pulse sensor 109R0605F401 With pulse sensor 109R0605M401 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 60 0.12 30 0.16 40 0.14 0.20 0.10 25 50 5.5 V 0.12 30 5.5 V 5.5 V 0.08 20 40 0.15 0.10 5 V 5 V 5 V 0.06 15 30 0.08 20 4.5 V 4.5 V 0.10 4.5 V 0.06 0.04 10 20 0.04 10 0.05 0.02 5 10 0.02 0 0 0 0 0 0 3 3 3 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m /min) 0.1 0.2 0.3 0.4 0.5 0.6 (m /min) 0.1 0.2 0.3 0.4 0.5 (m /min) 0 5 10 15 20 25 (CFM) 0 5 10 15 20 (CFM) 0 5 10 15 (CFM) Airflow Airflow Airflow 109R0612J401 With pulse sensor 109R0612G401 With pulse sensor 109R0612D401 With pulse sensor Operating voltage range Operating voltage range Operating voltage range 2 (inch H2O) (Pa) (inch H2O) (Pa) (inch H O) (Pa) 0.45 0.8 200 110 0.4 100 0.40 13.8 V 100 180 0.7 13.2 V 90 80 160 0.35 12 V 0.3 0.6 80 12 V 140 0.30 13.2 V 0.5 70 120 60 10.8 V 0.25 60 10.2 V 0.4 12 V 0.2 100 0.20 50 10.8 V 40 80 0.3 40 0.15 60 30 0.1 0.2 0.10 40 20 20 0.1 0.05 20 10 0 0 0 0 0 0 3 3 3 0.2 0.4 0.6 0.8 1.0 1.2 1.4 (m /min) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 (m /min) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 (m /min) 0 5 101520 25 30 35 40 45 (CFM) 0 5 10 15 20 25 30 (CFM) 0 5 10 15 20 25 30 (CFM) Airflow Airflow Airflow 109R0612S401 With pulse sensor 109R0612H401 With pulse sensor 109R0612F401 With pulse sensor Operating voltage range Operating voltage range Operating voltage range 2 2 (inch H O) (Pa) (inch H2O) (Pa) (inch H O) (Pa) 80 60 0.18 0.30 13.8 V 0.16 40 70 0.20 50 13.8 V 13.8 V 0.25 0.14 60 12 V 12 V 12 V 30 40 0.12 0.20 0.15 50 0.10 40 30 6 V 0.15 0.08 20 6 V 0.10 6 V 30 20 0.06 0.10 20 0.04 10 0.05 10 0.05 10 0.02 0 0 0 0 0 0 3 3 3 0.2 0.4 0.6 0.8 (m /min) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (m /min) 0.1 0.2 0.3 0.4 0.5 0.6 (m /min) 0 5 10 15 20 25 30 (CFM) 0 5 10 15 20 25 (CFM) 0 5 10 15 20 (CFM) Airflow Airflow Airflow 109R0612M401 With pulse sensor 109R0624J401 With pulse sensor 109R0624G401 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) 2 2 (inch H O) (Pa) (inch H O) (Pa) 0.50 120 0.12 30 0.8 200 0.45 110 180 13.8 V 0.7 26.4 V 100 0.10 25 0.40 160 0.6 24 V 90 0.35 12 V 27.6 V 140 0.08 80 20 0.5 0.30 120 70 21.6 V 24 V 0.25 0.06 60 15 0.4 100 7 V 0.20 50 20.4 V 80 0.3 0.04 40 10 0.15 60 0.2 30 0.10 40 0.02 20 5 0.1 0.05 20 10 0 0 0 0 0 0 3 3 3 0.1 0.2 0.3 0.4 0.5 (m /min) (m /min) (m /min) 0.2 0.4 0.6 0.8 1.0 1.2 1.4 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0 5 10 15 20 (CFM) 0 5 101520 25 30 35 40 45 (CFM) 0 5 10 15 20 25 30 (CFM) Airflow Airflow Airflow 75 Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure DC Fan 60 mm sq. DC