Product Information

FN5040-180-99

FN5040-180-99 electronic component of Schaffner

Datasheet
Power Line Filters 180A 0.3mH OUT FLTR Frequency Inverters

Manufacturer: Schaffner
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Obsolete
Availability Price Quantity
0 - Global Stock

MOQ : 1
Multiples : 1

Stock Image

FN5040-180-99
Schaffner

1 : USD 6941.4581
N/A

Obsolete
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Voltage Rating
Current Rating
Mounting Style
Termination Style
Series
Brand
Product Type
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
Mxhts
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
FN5040-24-84 electronic component of Schaffner FN5040-24-84

Power Line Filters 24A 2.4mH OUTPT FLTR Frequency Inverters
Stock : 0

FN5040-48-85 electronic component of Schaffner FN5040-48-85

Power Line Filters 48A 1.1mH OUTPT FLTR Frequency Inverters
Stock : 0

FN5040-4.5-82 electronic component of Schaffner FN5040-4.5-82

Schaffner Power Line Filters 4.5A 13mH 2.2uF Sine Wave Filter
Stock : 54

FN5040-62-86 electronic component of Schaffner FN5040-62-86

Schaffner Power Line Filters 62A 0.85mH OUT FLTR Frequency Inverters
Stock : 0

FN5040-260-99 electronic component of Schaffner FN5040-260-99

Power Line Filters 260A 0.2mH OUT FLTR Frequency Inverters
Stock : 0

FN5040-38-84 electronic component of Schaffner FN5040-38-84

Power Line Filters 38A 1.6mH OUTPT FLTR Frequency Inverters
Stock : 0

FN5040-410-99 electronic component of Schaffner FN5040-410-99

Power Line Filters 410A 0.13mH OUT FLTR Frequency Inverters
Stock : 0

FN5040-660-99 electronic component of Schaffner FN5040-660-99

Power Line Filters 660A 0.14mH OUT FLTR Frequency Inverters
Stock : 0

FN5040-750-99 electronic component of Schaffner FN5040-750-99

Power Line Filters 750A 0.12mH OUT FLTR Frequency Inverters
Stock : 0

FN5040-480-99 electronic component of Schaffner FN5040-480-99

Power Line Filters 480A 0.11mH OUT FLTR Frequency Inverters
Stock : 0

Image Description
EAP-30-102 electronic component of Cosel EAP-30-102

Power Line Filters EMI Filter
Stock : 0

RP135-16-4.7-W electronic component of Astrodyne RP135-16-4.7-W

Power Line Filters FILTER 1-PHASE HI PERF 16A 4.7NF
Stock : 0

RP600C-100-4.7-C-B electronic component of Astrodyne RP600C-100-4.7-C-B

Power Line Filters FILTER DC HI-PERF 100A 4.7NF
Stock : 0

3-103-677 electronic component of Schurter 3-103-677

Power Line Filters FILTER 1PH 2ST U 12A 250VAC/DC
Stock : 19

50TYT8 electronic component of Delta 50TYT8

Power Line Filters High Performance, 3-Phase, 4-Wire Filter, 480VAC, 50A, Chassis, Terminal Block-Terminal Block
Stock : 3

RP220-6-4.7-W electronic component of Astrodyne RP220-6-4.7-W

Power Line Filters FILTER DUAL-STAGE HI PERF 6A 4.7NF
Stock : 0

RP300-50-1000-S electronic component of Astrodyne RP300-50-1000-S

Power Line Filters FILTER 3-PHASE DELTA EMC HIPWR 50A 1000NF
Stock : 0

3B30D electronic component of Astrodyne 3B30D

Power Line Filters FILTER FCI 3PH 1970-001
Stock : 18

3-103-987 electronic component of Schurter 3-103-987

Power Line Filters FILTER 1PH 2ST V 250V PF M5
Stock : 0

5500.2222 electronic component of Schurter 5500.2222

Power Line Filters FSW Filter 1PH 2ST 36A 250VAC
Stock : 0

DATASHEET Sine wave filters FN 5040/FN 5045 LC Sine Wave Filter for Motor Drives Smooth sine wave without voltage peaks Approvals Perfect motor protection Reduce bearing currents Motor frequency up to 200 Hz Extended motor cable length capability UL 61800-5-1 up to 750 A for FN 5040, 480 A for FN 5045. For use with AC or DC drives (power conversion equipment) only Features and benefits Converts the rectangular PWM output voltage of Performance indicators motor drives into a smooth sine wave with low residual ripple Elimination of premature motor damage caused by high dv/dt, overvoltages, cable ringing, motor overheating, and eddy current losses Improves bearing life time because of bearing currents caused by circulating currents Complies with IEC 60034-17* and NEMA-MG1 requirements for general purpose motors Optional with NEMA 1 protective cover Technical specifications Typical applications Nominal operating voltage 3x480 VAC HVAC applications Rated operating voltage 3x525 VAC Pumps Motor frequency 0...70 Hz (up to 200Hz with derating (see graph)) Ventilators Switching frequency See filter selection table Conveyors 4.5 to 1200 A 45C Rated currents Compressors Motor cable length Up to 2,000 m (see graph) Elevators Impedance (uk) 8 to 10% 400 V, 50 Hz and rated current Cranes Residual ripple voltage <5% Medium voltage applications, deployed in front of High potential test voltage P > E 3000 VAC, 1 minute the step-up transformer P > P 2500 VAC, 1 minute Protection category IP 00 (FN 5040) Retrofit installations with motor drives IP 20 (FN 5045) Motor drive with long motor cable Overload capability 1.5 rated current for 1 minute, once per hour Motor drive with multiple motors in parallel Ambient temperature range -25C to +45C fully operation +45C to 70C derated operation* -25C to +85C transport and storage Typical electrical schematic EIS 200 Insulation class Flammability corresponding to UL 94 V-2 Design corresponding to Chokes: EN 61558-2-20 or EN 60076-6 Filter: UL 61800-5-1, EN 61800-5-1 >100,000 hours MTBF Rated currents 4.5 to 1200 A 50C (480 V filters) * I = I *((T T )/(T T )) = I *((70C-T )/25C) derated nominal max- amb max- nominal nom amb2 Output filters Schaffner Group Datasheets 29 Oct 2019 Filter selection table Filter Rated Rated Typical motor Typical motor Nominal Nominal Capacitance Min. Typical Input/Output Weight current current drive power drive power inductance capacitance connection switching power connections 45C/ 45C/ rating 400 rating 480 frequency loss*** 50Hz 100Hz V* V** A A kW kW mH F kHz W kg FN 5040-4.5-82 4.5 4.05 1.1/1.5 1.3/1.8 13 2.2 Y 4 65 -82 3.3 FN 5040-8-82 8 7.2 2.2/3 2.64/3.6 6.9 4.7 Y 4 80 -82 4.6 FN 5040-10-83 10 9 4 4.8 5.2 6.8 Y 4 90 -83 6.1 FN 5040-17-83 17 15.3 5.5/7.5 6.6/9.0 3.1 10 Y 4 115 -83 7.8 FN 5040-24-84 24 21.6 11 13.2 2.4 10 Y 4 150 -84 14.4 FN 5040-38-84 38 34.2 15/18.5 18/22.2 1.6 10 Y 4 170 -84 25.0 FN 5040-48-85 48 43.2 22 26.4 1.1 14.7 Y 4 260 -85 33.0 FN 5040-62-86 62 55.8 30 36 0.85 30 Y 3 280 -86 36.0 FN 5040-75-87 75 67.5 37 44.4 0.75 30 Y 3 330 -87 42.0 FN 5040-115-87 115 103.5 45/55 52.8/66 0.5 20 3 500 -87 68.0 FN 5040-180-99 180 162 75/90 90/108 0.3 33 3 680 -99 86.0 FN 5040-260-99 260 234 110/132 132/158.4 0.2 47 3 880 -99 125.0 FN 5040-410-99 410 369 160/200 192/240 0.13 66 3 1100 -99 184.0 FN 5040-480-99 480 432 250 300 0.11 94 3 1350 -99 235.0 FN 5040-660-99 660 594 315/355 378/426 0.14 141 2 2000 -99 310.0 FN 5040-750-99 750 675 400 480 0.12 165 2 2800 -99 470.0 FN 5040-880-99 880 792 400/500 480/600 0.11 188 2 3400 -99 640.0 FN 5040-1200-99 1200 1080 560/630 672/756 0.075 282 2 3800 -99 680.0 FN 5045-4.5-44 4.5 4.05 1.1/1.5 1.3/1.8 13 2.2 Y 4 65 -44 4.1 FN 5045-8-44 8 7.2 2.2/3 2.64/3.6 6.9 4.7 Y 4 80 -44 5.4 FN 5045-10-44 10 9 4 4.8 5.2 6.8 Y 4 90 -44 6.9 FN 5045-17-33 17 15.3 5.5/7.5 6.6/9.0 3.1 10 Y 4 115 -33 9.0 FN 5045-24-33 24 21.6 11 13.2 2.4 10 Y 4 150 -33 15.6 FN 5045-38-33 38 34.2 15/18.5 18/22.2 1.6 10 Y 4 170 -33 18.9 FN 5045-48-34 48 43.2 22 26.4 1.1 14.7 Y 4 260 -34 35.8 FN 5045-62-34 62 55.8 30 36 0.85 30 Y 3 280 -34 37.8 FN 5045-75-35 75 67.5 37 44.4 0.75 30 Y 3 330 -35 60.0 FN 5045-115-35 115 103.5 45/55 52.8/66 0.5 20 3 500 -35 70.0 FN 5045-180-99 180 162 75/90 90/108 0.3 33 3 680 -99 92.0 FN 5045-260-99 260 234 110/132 132/158.4 0.2 47 3 880 -99 131.0 FN 5045-410-99 410 369 160/200 192/240 0.13 66 3 1100 -99 198.0 FN 5045-480-99 480 432 250 300 0.11 94 3 1350 -99 243.0 FN 5045-660-99 660 594 315/355 378/426 0.14 141 2 2000 -99 425.0 FN 5045-750-99 750 675 400 480 0.12 165 2 2800 -99 482.0 FN 5045-880-99 880 792 400/500 480/600 0.11 188 2 3400 -99 652.0 FN 5045-1200-99 1200 1080 560/630 672/756 0.075 282 2 3800 -99 692.0 * General purpose four-pole (1500 r/min) AC induction motor rated 400 V/50 Hz. ** General purpose four-pole (1500 r/min) AC induction motor rated 480 V/50 Hz. *** Exact value depends on the motor cable length and type, switching frequency and further stray parameters of the system. Required drive settings Ensure the drives switching frequency is set to the required minimum switching frequency (see filter selection table). The mode of operation must be scalar (V/Hz) with a fixed switching frequency. Check the drives manufacturer manual whether special settings are necessary. In any doubt contact the drives manufacturer. CAUTION: If the motor drives settings are not correct the filter may be damaged.

Tariff Desc

8543.70.00 - ELECTRICAL MACHINES AND APPARATUS, HAVING INDIVIDUAL FUNCTIONS, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER: Other machines and apparatus Free
91 .. Other
SCHAFFNER EMC
Schaffner EMC Inc
Schaffner EMC Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted