DATASHEET Three-Stage Filters FN 700 Z Three-stage EMC/EMI Filter Rated currents from 6 to 20 A Approvals IEC inlet for 6 and 10 A versions Up to 3 GHz attenuation High surge voltage protection Features and benefits FN 700 Z series is designed to meet highest filter attenuation requirements over a wide range starting from a few kilohertz up to 3 GHz Performance indicators High surge voltage protection Choosing the FN 700 Z product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances Standard filters are a practical solution helping you to pass EMI system approval in a short time Exceptional conducted attenuation performance, based on three-stage design and chokes with high saturation resistance and excellent thermal behavior Integrated gas discharge tubes and suppressors IEC inlet version for 6 and 10 A types Custom-specific versions on request Technical specifications Typical applications Maximum continuous operating voltage 250 VAC, 50/60 Hz Operating frequency DC to 400 Hz Facility management Rated currents 6 to 20 A 40C max. Information protection High potential test voltage P > PE 420 VAC for 2 sec Telecommunication P > N 420 VAC for 2 sec Data processing Temperature range (operation and storage) -25C to +85C (25/85/21) Flammability corresponding to UL 94 V-2 or better Medical equipment UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Design corresponding to Electrical and electronic equipment MTBF 40C/230 V (Mil-HB-217F) 450,000 hours Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 11 Oct 2018 Filter selection table Filter* Rated current Leakage current* Inductance Capacitance Resistance Input Output Weight 40C (25C) 230 VAC/50 Hz L L1 Cx Cx1 Cy Cy1 R connections connections A A H mH F F nF nF M kg FN 700 Z-6-06 6 (6.9) 440 50 17.1 1 2.5 0.33 IEC C14 -06 2 FN 700 Z-10-06 10 (11.6) 440 50 9.4 1 2.5 0.33 IEC C14 -06 2.3 FN 700 Z-20-03 20 (23) 2600 60 5.5 1 2.2 5 10 0.33 -03 -03 3.5 * Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Typical filter attenuation Per CISPR 17 A=50 /50 sym B=50 /50 asym C=0.1 /100 sym D=100 /0.1 sym 6 A types 10 to 20 A types Mechanical data 6 and 10 A types 20 A types Dimensions 6 A 10 A 20 A Tolerances A 200 250 275 0.3 B 80 80 110 0.3 C 50 50 50 0.2 D 15 25 25 0.3 E 85 100 112.5 0.2 F 50 50 94 0.2 G 40 40 60 0.3 H 30 30 25 0.5 I 20 20 15 0.3 J 40 40 55 0.3 K 20 20 34 0.3 L 40 40 94 0.1 M M4 x 6 M4 x 6 M4 x 6 N 6.3 x 0.8 6.3 x 0.8 M4 All dimensions in mm 1 inch = 25.4 mm Tolerances according: ISO 2768-m/EN 22768-m Please visit www.schaffner.com to find more details on filter connectors.