Product data sheet ATV340U07N4 Characteristics Variable speed drive, Altivar Machine ATV340, 0.75 kW Heavy Duty, 400 V, 3 phases Main Range of Product Altivar Machine ATV340 Product or Component Variable speed drive Type Product Specific Machine Application Variant Standard version Mounting Mode Cabinet mount Communication Port Modbus serial Protocol Option card Communication module, Profibus DP V1 Communication module, Profinet Communication module, DeviceNet Communication module, CANopen Communication module, EtherCAT Phase 3 phase Supply frequency 50...60 Hz +/- 5 % Us rated supply 380...480 V - 15...10 % voltage Nominal output current 2.2A Motor power kW 1.1KW normal duty 0.75kW heavy duty Maximum Horse Power 1.5Hp normal duty Rating 1hp heavy duty EMC filter Class C3 EMC filter integrated IP degree of protection IP20 Complementary Discrete input number 5 Discrete input type PTI programmable as pulse input 030kHz, 24 V DC 30 V) DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm programmable Number of preset speeds 16 preset speeds Discrete output number 2.0 Discrete output type Programmable output DQ1, DQ2 30 V DC 100mA Analogue input number 2 Analogue input type AI1 software-configurable current 0...20 mA 250 Ohm 12 bits AI1 software-configurable temperature probe or water level sensor AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits Analogue output number 2 Analogue output type Software-configurable voltage AQ1 0...10 V DC 470Ohm 10 bits Software-configurable current AQ1 0...20 mA 500Ohm 10 bits Relay output number 2 Output voltage <= power supply voltage Relay output type Relay outputs R1A Relay outputs R1C 100000cycles Relay outputs R2A Relay outputs R2C 100000cycles Jan 18, 2022 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Maximum switching current Relay output R1C resistive, cos phi = 1 3A 250 V AC Relay output R1C resistive, cos phi = 1 3A 30 V DC Relay output R1C inductive, cos phi = 0.4 7ms 2A 250 V AC Relay output R1C inductive, cos phi = 0.4 7ms 2A 30 V DC Relay output R2C resistive, cos phi = 1 5A 250 V AC Relay output R2C resistive, cos phi = 1 5A 30 V DC Relay output R2C inductive, cos phi = 0.4 7ms 2A 250 V AC Relay output R2C inductive, cos phi = 0.4 7ms 2A 30 V DC Minimum switching current Relay output R1B 5mA 24 V DC Relay output R2C 5mA 24 V DC Physical interface 2-wire RS 485 Connector type 1 RJ45 Method of access Slave Modbus RTU Transmission Rate 4.8 kbit/s 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s Transmission frame RTU Number of addresses 1247 Data format 8 bits, configurable odd, even or no parity Type of polarization No impedance 4 quadrant operation possible True Asynchronous motor control profile Constant torque standard Variable torque standard Optimized torque mode Synchronous motor control profile Permanent magnet motor Reluctance motor Pollution degree 2 EN/IEC 61800-5-1 Maximum output frequency 0.599kHz Acceleration and deceleration ramps S, U or customized Linear adjustable separately from 0.01...9999 s Motor slip compensation Can be suppressed Not available in permanent magnet motor law Automatic whatever the load Adjustable Switching frequency 2...16 kHz adjustable 14...16 kHz with derating factor Nominal switching frequency 4 kHz Braking to standstill By DC injection Brake chopper integrated True Line current 2.6A 380 V normal duty) 2.1A 480 V normal duty) 3.4A 380 V heavy duty) 2.6A 480 V heavy duty) Line current 2.6A 480 V without line choke heavy duty) 2.6A 380 V with external line choke normal duty) 2.1A 480 V with external line choke normal duty) 1.9A 380 V with external line choke heavy duty) 1.6A 480 V with external line choke heavy duty) 3.4A 380 V without line choke heavy duty) Maximum Input Current per Phase 3.4A Maximum output voltage 480V Apparent power 2.2KVA 480 V normal duty) 2.2kVA 480 V heavy duty) Maximum transient current 3.1A 60 s normal duty) 3.3A 60 s heavy duty) 3.8A 2 s normal duty) 4A 2 s heavy duty) Electrical connection Screw terminal 1.5...4 mm line side Screw terminal 4...6 mm DC bus Screw terminal 1.5...4 mm motor Screw terminal 0.2...2.5 mm control Prospective line Isc 5kA Base load current at high overload 2.2A Base load current at low overload 2.8A 2