Ships to you between Fri. 10 May to Tue. 14 May
GV2ME07 Schneider
Ships to you between Mon. 06 May to Fri. 10 May
LED Lighting Fixture Accessories INDICATING BANK ACCESSORIES 100MM Stock : 6
LED Lighting Fixture Accessories REPLACEMENT CAP FOR XVB WIRING BASE Stock : 0
LED Lighting Fixtures Mounting Base f/ XVB Stock : 9
LED Lighting Fixtures FIXING BASE 80MM w/ SUPPORT TUBE Stock : 2
LED Lighting Fixture Accessories INDICATING BANK Stock : 0
LED Lighting Fixtures FIXING BASE 80MM W/ SUPPORT TUBE Stock : 7
LED Lighting Fixture Accessories INDICATING BANK ACCESSORIES 70MM Stock : 13
LED Lighting Fixture Accessories INDICATING BANK ASSRY 14MM+OPTIONS Stock : 3
LED Lighting Fixture Accessories INDICATING BANK Stock : 7
LED Lighting Fixture Accessories INDICATING BANK ACCESSORIES 400MM Stock : 1
Contactors - Electromechanical 2PNO 24VAC Stock : 1
Contactor:4-pole; NO x4; 24VDC; 7A; DIN, on panel; B7D; -20÷55°C Stock : 4
Contactor Insulation Barrier Stock : 1
Contactors - Electromechanical RELAY CONTACTOR 30A 120VAC QC Stock : 151
Undervoltage relase; 230/240VAC; side Stock : 1
Auxiliary contacts; Auxiliary contacts: NC x2; front Stock : 1
Contactor:1-pole installation; NC; 24VAC; 24VDC; 20A; DIN; IKD Stock : 0
Contactor:3-pole installation; NO x3; 24VAC; 24VDC; 25A; DIN; IKD Stock : 0
Quick connect surge suppressor - For BG series mini contactor - 225 VDC (Diode). Stock : 0
Contactors - Electromechanical MINI CONTACTOR, 9A/380/440V Stock : 1
Product data sheet GV2ME07 Characteristics TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, push buttons, 1.6 to 2.5 A, screw clamp Product availability: Stock - Normally stocked in distribution facility Main Range TeSys Product name TeSys GV2 Device short name GV2ME Device application Motor Trip unit technology Thermal-magnetic Complementary Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode Clipped on 35 mm symmetrical DIN rail Screwed on panel (with adaptor plate) Operating position Any position Motor power kW 0.75 kW at 400/415 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz 1.5 kW at 690 V AC 50/60 Hz Breaking capacity 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 Ics rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Control type Push-button In rated current 2.5 A Thermal protection adjustment range 1.6...2.5 A Magnetic tripping current 33.5 A System Voltage AC 50/60 Hz conforming to IEC 60947-2 Ui rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 Ith conventional free air thermal current 2.5 A conforming to IEC 60947-4-1 Uimp rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Power dissipation per pole 2.5 W Mechanical durability 100000 cycles Electrical durability 100000 cycles AC-3 at 440 V Operating rate 25 cyc/h Rated duty Continuous conforming to IEC 60947-4-1 Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Connections - terminals Screw clamp terminals 2 cable(s) 0...0.01 in (1...6 mm) solid Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) flexible without cable end Screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) flexible with cable end Tightening torque 15.04 lbf.in (1.7 N.m) on screw clamp terminals Suitability for isolation Yes conforming to IEC 60947-1 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Height 3.5 in (89 mm) Width 1.77 in (45 mm) Depth 3.08 in (78.2 mm) Product weight 0.57 lb(US) (0.26 kg) Environment Standards IEC 60947-1 VDE 0113 NF C 79-130 CSA C22.2 NF C 63-120 IEC 60947-4-1 NF C 63-650 IEC 60947-2 UL 508 VDE 0660 EN 60204 Product certifications GL ATEX DNV BV TSE CCC UL RINA LROS (Lloyds register of shipping) SETI EAC CEBEC EZU CSA Protective treatment TH IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK04 Ambient air temperature for operation -4...140 F (-20...60 C) Ambient air temperature for storage -40...176 F (-40...80 C) Fire resistance 1760 F (960 C) conforming to IEC 60695-2-1 Operating altitude 6561.68 ft (2000 m) Ordering and shipping details Category 22367 - MANUAL STR PROTECTOR - GV2 Discount Schedule I11 GTIN 00785901211945 Nbr. of units in pkg. 1 Package weight(Lbs) 0.57000000000000006 Returnability Y Country of origin TH Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 0631 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference contains SVHC above the threshold - Go to CaP for more details- Go to CaP for more details Product environmental profile Available Product end of life instructions Need no specific recycling operations 2