LV1 09 Gesamt EN.book Seite 1 Mittwoch, 11. Februar 2009 3:54 15 Siemens AG 2009 Protection Equipment 5 5/2 Introduction 3RV Circuit Breakers/Motor Starter Protectors up to 100 A 5/5 General data 5/7 For motor protection 5/11 For motor protection with overload relay function 5/12 For starter combinations 5/13 For transformer protection 5/14 For fuse monitoring 5/15 For system protection according to UL 489/CSA C22.2 No. 5-02 5/16 For transformer protection according to UL 489/CSA C22.2 No.5-02 5/17 For distance protection Accessories 5/18 Mountable accessories 5/22 Busbar accessories 5/25 Rotary operating mechanisms 5/27 Mounting accessories 5/31 Enclosures and front plates 3RV Molded Case Motor Starter Protectors up to 800 A 5/34 General data 5/35 For motor protection 5/36 For starter combinations Accessories 5/37 Mountable accessories 5/38 Rotary operating mechanisms Mounting accessories Overload Relays 5/39 General data 3RU1 Thermal Overload Relays 5/43 3RU11 for standard applications 5/47 Accessories 3RB2 Solid-State Overload Relays 5/48 3RB20, 3RB21 for standard applications 5/56 3RB22, 3RB23 for high-feature applications 5/60 Accessories Siemens LV 1 2009LV1 09 Gesamt EN.book Seite 2 Mittwoch, 11. Februar 2009 3:54 15 Siemens AG 2009 Protection Equipment Introduction Overview Type 3RV10 3RV11 3RV13 3RV14 3RV16 3RV16 3RV17 3RV18 3RV1 circuit breakers/motor starter protectors up to 100 A Uses 1) 1) System protection -- -- -- -- Motor protection -- -- -- -- -- -- -- Motor protection with -- -- -- -- -- -- -- overload relay function Starter combinations -- -- -- -- -- -- -- Transformer protection -- -- -- -- -- Fuse monitoring -- -- -- -- -- -- -- Voltage transformer -- -- -- -- -- -- -- circuit breakers for distance protection Size S00, S0, S2, S3 S0, S2, S3 S0, S2, S3 S0, S2 S00 S00 S0, S3 S0 Rated current I n Size S00 A to 12 -- -- -- 0.2 to 3 -- -- Size S0 A to 25 to 25 to 25 to 20 -- -- to 22 to 20 Size S2 A to 50 to 50 to 50 to 40 -- -- -- -- Size S3 A to 100 to 100 to 100 -- -- -- to 70 -- 2) 2) 2) 2) 2) Rated operational voltage V 690 AC 690 AC 690 AC 690 AC 690 AC 400 AC 690 AC 690 AC U acc. to IEC e 2 Rated frequency Hz 50/60 50/60 50/60 50/60 50/60 16 / ... 60 50/60 50/60 3 Trip class CLASS 10 CLASS 10 -- CLASS 10 -- -- -- -- CLASS 20 3) Thermal A 0.11 ... 0.16 0.11 ... 0.16 None 0.11 ... 0.16 0.2 1.4 ... 3 0.16 ... 70 0.16 ... 20 overload release to to to non- non- A 80 ... 100 80 ... 100 28 ... 40 adjustable adjustable Electronic trip units A multiple of the rated current 13 times 13 times 13 times 20 times 6 times 4 ... 7 times 13 times 20 times 4) 4) Short-circuit breaking kA 50/100 50/100 50/100 50/100 100 50 capacity I at 400 V AC cu Accessories For sizes S00 S0 S2 S3 S0 S2 S3 S0 S2 S3 S0 S2 S00 S00 S0, S3 S0 5) 5) Auxiliary switches Signal switch -- -- -- -- -- Undervoltage trip units -- -- -- Shunt trip units -- -- -- Isolator modules -- -- -- -- -- -- -- -- Insulated three-phase -- -- -- -- -- -- busbar systems Busbar adapters -- -- Door-coupling rotary -- -- -- operating mechanisms Remote motorized -- -- -- -- -- -- -- -- -- operating mechanisms Link modules -- -- Enclosures for surface -- -- -- -- -- mounting Enclosures for flush -- -- -- -- -- -- -- -- -- mounting Front plates -- -- Infeed system -- -- -- -- -- -- -- -- -- -- -- -- 1) For symmetrical loading of the three phases. Has this function or can use this accessory 2) 500 V AC with molded-plastic enclosure. -- Does not have this function or cannot use this accessory 3) For overload protection of the motors, appropriate overload relays must be used. 4) According to UL 489 - at 480 Y/277 V AC: for size S0 50 kA, for size S3 65 kA - at 480 V AC: for size S3 (10 A up to 30 A) 65 kA. 5) Only lateral auxiliary switches can be fitted. Siemens LV 1 2009 5/2 5