Product Information

3UG4513-1BR20

3UG4513-1BR20 electronic component of Siemens

Datasheet
Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20

Manufacturer: Siemens
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 149.175 ea
Line Total: USD 149.18

24 - Global Stock
Ships to you between
Wed. 08 May to Tue. 14 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
2 - WHS 1


Ships to you between Wed. 08 May to Tue. 14 May

MOQ : 1
Multiples : 1
1 : USD 568.175
3 : USD 539.775

24 - WHS 2


Ships to you between Wed. 08 May to Tue. 14 May

MOQ : 1
Multiples : 1
1 : USD 149.175
5 : USD 147.173

     
Manufacturer
Product Category
Mounting Type
Leads
Kind Of Output 1
Controlled Parameter
Output 1 Electrical Parameters
Power Supply
Ip Rating
Controlled Parameter Range
Type Of Module
Operating Temperature
Contact Actuation Delay
Voltage Between Phases For Three Phase System
Body Dimensions
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
3UG4615-1CR20 electronic component of Siemens 3UG4615-1CR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 10

3UG4616-1CR20 electronic component of Siemens 3UG4616-1CR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 7

3UG4614-1BR20 electronic component of Siemens 3UG4614-1BR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 14

3UG4581-1AW30 electronic component of Siemens 3UG4581-1AW30

Module: insulation monitoring relay; insulation resistance
Stock : 0

3UG4615-2CR20 electronic component of Siemens 3UG4615-2CR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 6

3UG4617-1CR20 electronic component of Siemens 3UG4617-1CR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 5

3UG4513-2BR20 electronic component of Siemens 3UG4513-2BR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 0

3UG4614-2BR20 electronic component of Siemens 3UG4614-2BR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 0

3UG4616-2CR20 electronic component of Siemens 3UG4616-2CR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 1

3UG4617-2CR20 electronic component of Siemens 3UG4617-2CR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 2

Image Description
3UG4616-1CR20 electronic component of Siemens 3UG4616-1CR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 7

TA75DU32 electronic component of ABB TA75DU32

Electromechanical Relay 25A 3PDT(98x60x127.7)mm DIN Rail Thermal Overload Relay
Stock : 0

TA75DU80 electronic component of ABB TA75DU80

Electromechanical Relay 25A 3PDT(98x60x127.7)mm DIN Rail Thermal Overload Relay
Stock : 0

400-13PX electronic component of TE Connectivity 400-13PX

Industrial Relays WILMAR UNDERVOLTAGE
Stock : 2

400-1HX electronic component of TE Connectivity 400-1HX

General Purpose Relays WILMAR UNDERVOLT 12
Stock : 0

401-43SX electronic component of TE Connectivity 401-43SX

Electromechanical Relay
Stock : 5

401-45X electronic component of TE Connectivity 401-45X

Industrial Relays WILMAR UNDERVOLTE 12
Stock : 1

40.31.8.012.0000 electronic component of Finder 40.31.8.012.0000

Relay: electromagnetic; SPDT; Ucoil:12VAC; 10A/250VAC; 10A/30VDC
Stock : 136

40.31.8.024.0000 electronic component of Finder 40.31.8.024.0000

Relay: electromagnetic; SPDT; Ucoil:24VAC; 10A/250VAC; 10A/30VDC
Stock : 293

40.31.9.024.0000 electronic component of Finder 40.31.9.024.0000

Relay: electromagnetic; SPDT; Ucoil:24VDC; 10A/250VAC; 10A/30VDC
Stock : 100

Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Overview Solid-state line monitoring relays provide maximum protection for mobile machines and plants or for unstable networks. Net- work and voltage faults can be detected early and rectified be- fore far greater damage ensues. Depending on the version, the relays monitor phase sequence, phase failure with and without N conductor monitoring, phase unbalance, undervoltage or overvoltage. Phase unbalance is evaluated as the difference between the greatest and the smallest phase voltage relative to the greatest phase voltage. Undervoltage or overvoltage exists when at least one phase voltage deviates by 20 % from the set rated system voltage or the directly set limit values are overshot or undershot. The rms value of the voltage is measured. With the 3UG46 17 or 3UG46 18 relay, a wrong direction of rota- tion can also be corrected automatically. Function 3UG45 11 monitoring relays 3UG45 12 monitoring relays The 3UG45 11 phase sequenced relay monitors the phase se- The 3UG45 12 line monitoring relay monitors three-phase net- quence in a three-phase network. No adjustments are required works with regard to phase sequence, phase failure and phase for operation. The device has an internal power supply and unbalance of 10 %. Thanks to a special measuring method, a works using the closed-circuit principle. If the phase sequence phase failure is reliably detected in spite of the wide voltage at the terminals L1-L2-L3 is correct, the output relay picks up af- range from 160 ... 690 V AC and feedback through the load of up ter the delay time has elapsed and the LED is lit. If the phase se- to 90 %. The device has an internal power supply and works us- quence is wrong, the output relay remains in its rest position. ing the closed-circuit principle. No adjustments are required. When the mains voltage is switched on, the green LED is lit. If the Note: When one phase fails, connected loads (motor windings, phase sequence at the terminals L1-L2-L3 is correct, the output lamps, transformers, coils, etc.) create a feedback voltage at the relay picks up. If the phase sequence is wrong, the red LED terminal of the failed phase due to the network coupling. Be- flashes and the output relay remains in its rest position. If a phase cause the 3UG45 11 relays are not resistant to voltage feedback, fails, the red LED is permanently lit and the output relay drops. such a phase failure is not detected. Should this be required, then the 3UG45 12 monitoring relay must be used. Note: The red LED is a fault diagnostic indicator and does not show the current relay status. The 3UG45 12 monitoring relay is suitable for line frequencies of 50/60 Hz. Phase failure Correct phase sequence L1-L2-L3 L2-L3 L1-L2-L3 L1-L2-L3 11/14 11/14 ON 11/12 11/12 21/24 21/24 21/22 21/22 LED rd OFF ON OFF Wrong phase sequence Phase loss Wrong phase sequence L3-L2-L1 L3-L2-L1 11/14 11/14 11/12 11/12 OFF 21/24 21/24 21/22 21/22 LED rd OFF FLASH OFF Phase sequence Siemens 2010 59 NSB0 01566a NSB0 01565a NSB0 01568a NSB0 01567aMonitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring 3UG45 13 monitoring relays 3UG46 14 monitoring relays The 3UG45 13 line monitoring relay monitors three-phase net- The 3UG46 14 line monitoring relay has a wide voltage range works with regard to phase sequence, phase failure, phase un- and an internal power supply. The device is equipped with a dis- balance and undervoltage of 20 %. The device has an internal play and is parameterized using three buttons. It monitors three- power supply and works using the closed-circuit principle. The phase networks with regard to phase unbalance from 5 ... 20 %, hysteresis is 5 %. The integrated response delay time is adjust- phase failure, undervoltage and phase sequence. The hystere- able from 0 ... 20 s and responds to undervoltage. If the direction sis is adjustable from 1 ... 20 V. In addition the device has a re- is incorrect, the device switches off immediately. Thanks to a sponse delay and ON-delay from 0 ... 20 s in each case. The in- special measuring method, a phase failure is reliably detected in tegrated response delay time responds to phase unbalance and spite of the wide voltage range from 160 ... 690 V AC and feed- undervoltage. If the direction is incorrect, the device switches off back up to 80 % through the load. When the mains voltage is immediately. Thanks to a special measuring method, a phase switched on, the green LED is lit. If the phase sequence at the failure is reliably detected in spite of the wide voltage range from terminals L1-L2-L3 is correct, the output relay picks up. If the 160 ... 690 V AC and feedback up to 80 % through the load. phase sequence is wrong, the red LED flashes and the output The 3UG46 14 monitoring relay can be operated on the basis of relay remains in its rest position. If a phase fails, the red LED is either the open-circuit or closed-circuit principle and with man- permanently lit and the output relay drops. ual or auto RESET. Note: With the closed-circuit principle selected The red LED is a fault diagnostic indicator and does not show the current relay status. The 3UG45 13 monitoring relay is suitable Wrong phase sequence for line frequencies of 50/60 Hz. L3-L2-L1 Phase failure and undervoltage 11/14 11/12 L1-L2-L3 L2-L3 L1-L2-L3 Hysteresis 5 % 21/24 -20 % 3~ n 21/22 11/14 Phase failure 11/12 L1-L2-L3 L2-L3 L1-L2-L3 21/24 21/22 11/14 NSB0 01569a LED rd 11/12 OFF ON OFF ON OFF 21/24 Phase loss Delay 21/22 Wrong phase sequence Undervoltage L3-L2-L1 < Hysteresis x-y 11/14 11/12 11/14 11/12 21/24 21/22 21/24 LED rd 21/22 OFF FLASH OFF Delay Phase sequence onDelay Unbalance Hysteresis > Asy 2 % 0 % 11/14 11/12 21/24 21/22 Delay onDelay Siemens 2010 60 NSB0 01570a NSB0 01571a NSB0 01576a NSB0 01578a NSB0 01577a

Tariff Desc

8536.49.00 TC 17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC 8909066 having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 low profile, OTHER THAN reed relays, being EITHER of the following
a) height NOT exceeding 21.24mm
b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following
a) one, two or three contacts
b) maximum continuous contact current rating of NOT less than 15A
c) maximum contact voltage rating of NOT less than 380V
d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts having ANY of the following:
a) spring loaded terminals
b) plug-in screw terminals
c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following
a) maximum switching current NOT exceeding 5A AC or DC
b) switching voltage NOT exceeding 250V AC or DC
c) body dimensions NOT exceeding 31mm x 36mm x 19mm

8536.49 TC 8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics
a) trip time NOT exceeding 5 s at 6 times full load current
b) manual reset
c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following
a) normally closed main poles
b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8536.49.00 solid state having an operating voltage NOT exceeding 600VAC or 300VDC but NOT including protective monitoring TC 9320885

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted