Other than T00425, T0604 Nylon Tubing Series T/TIA 20 m roll 100 m roll (T1613 is reel.) Model/Specifications For general pneumatic Tubing size tubing, Nylon tubing Metric size (Series T) Inch size (Series TIA) Burst Pressure Characteristics Model T0425 T0403 T0604 T0645 T0806 T1075 T1209 T1613 TIA01 TIA05 TIA07 TIA11 TIA13 Curve and Operating Pressure Tubing O.D. (mm) 4 4 6 6 8 10 12 16 3.18 4.76 6.35 9.53 12.7 Tubing I.D. (mm) 2.5 3 4 4.5 6 7.5 9 13 2.18 3.48 4.57 6.99 9.56 Black (B) White (W) Red (R) Blue (BU) Yellow (Y) Green (G) Nominal size (inch) Maximum operating pressure 5 5 1 3 1 3 1 32 16 8 16 4 8 2 Operating temperature (C) Fluid Air/Water Max. Precautions operating 1.5 MPa pressure (at 20C) Be sure to read before handling. Refer to pages 15-18-3 to 4 for Safety Burst Refer to the burst pressure characteristics curve. Instructions and Common Precautions pressure on the products mentioned in this Min. catalog, and refer to pages 15-1-10 to bending 13 25 24 36 48 60 75 100 15 20 30 60 75 11 for Precautions on every series. radius (mm) Caution Operating 20 to +60C (Water: 0 to 40C) (No freezing) temperature 1. Applicable for general industrial water. Please consult with SMC if using other Material Nylon 12 kinds of fluid. Surge pressure must be under the max. operating pressure. How to Order If the surge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes. T0425 B 20 2. The value of the max. operating pressure Length per roll is at a temperature of 20C. Refer to the Color Symbol Length Tubing model burst pressure characteristics curve for Symbol Color Symbol Color 20 20 m roll other temperatures. 100 100 m roll (Black and white only) B Black BU Blue Furthermore, abnormal temperature rises W White Y Yellow caused by adiabatic compression may R Red G Green result in the burst of the tube. Made to Order (Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.) 100 m reel Metric size and Inch size except 16: Suffix -X3 to the end of part number. Ex.) TS0425R-100-X3 Longer length reel Metric size: Suffix -X3 to the end of part number. Ex.) TS0425G-500-X3 20 m roll Inch size: Suffix -X4 to the end of part number. Ex.) TISA01BU-20-X4 Made to Order Availability Model Part no. T0425 T0604 T0806 T1075 T1209 TIA01 TIA05 TIA07 TIA11 TIA13 Color Length 100 m reel Black, White, 150 m reel Red, Blue, X3 200 m reel Yellow, Green 500 m reel 20 m roll Red, Blue, Yellow, Green X4 15-6-2 Burst pressure (MPa)Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of Note 1)Cautio,Warnin orDange. To ensure safety, be sure to observe ISO 4414 , Note 2) JIS B 8370 and other safety practices. Operator error could result in injury or equipment damage. Caution : Operator error could result in serious injury or loss of life. Warning : In extreme conditions, there is a possible result of serious injury or loss of life. Danger : Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems. Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2.Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. 2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4. Contact SMC if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 15-18-3