Product Information

63-13-115-6

63-13-115-6 electronic component of Sola

Datasheet
Power Conditioning 150VA 120V In/Out

Manufacturer: Sola
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 792.477 ea
Line Total: USD 792.48

1 - Global Stock
Ships to you between
Fri. 03 May to Thu. 09 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
1 - Global Stock


Ships to you between Fri. 03 May to Thu. 09 May

MOQ : 1
Multiples : 1
1 : USD 784.1794
3 : USD 772.4194
5 : USD 760.83
10 : USD 743.8594

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Input Voltage-nominal
Output Voltage
Output Power
Voltage Regulation Accuracy
Number of Outlets
Features
Mounting Type
Input Voltage
Product
Brand
Cnhts
Hts Code
Mxhts
Product Type
Factory Pack Quantity :
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
63-23-112-4 electronic component of Sola 63-23-112-4

Power Conditioning 120VA 120V OUT
Stock : 1

63-23-125-4 electronic component of Sola 63-23-125-4

Power Conditioning 250VA 120V OUT
Stock : 1

63-23-210-C8 electronic component of Sola 63-23-210-C8

6323210C8 sola
Stock : 1

63-13-125-6 electronic component of Sola 63-13-125-6

Power Conditioning 250VA 120V In/Out
Stock : 0

63-13-150-5 electronic component of Sola 63-13-150-5

63131505 sola
Stock : 0

63-23-150-8 electronic component of Sola 63-23-150-8

Power Conditioning 500VA 120-240V OUT
Stock : 3

63-23-175-8 electronic component of Sola 63-23-175-8

Power Conditioning 120-480V TO 120-240V
Stock : 14

63-23-220-8 electronic component of Sola 63-23-220-8

Power Conditioning 2000VA 120-240V OUT
Stock : 4

63-23-612-8 electronic component of Sola 63-23-612-8

Power Conditioning 120VA MCR HW REGULATOR 50
Stock : 0

63-13-150-6 electronic component of Sola 63-13-150-6

Power Conditioning 500VA 120V In/Out
Stock : 0

Image Description
63-23-210-8 electronic component of Solahd 63-23-210-8

Power Protection and Conditioning
Stock : 0

63-13-125-6 electronic component of Sola 63-13-125-6

Power Conditioning 250VA 120V In/Out
Stock : 0

63-23-150-8 electronic component of Sola 63-23-150-8

Power Conditioning 500VA 120-240V OUT
Stock : 3

63-23-175-8 electronic component of Sola 63-23-175-8

Power Conditioning 120-480V TO 120-240V
Stock : 14

63-23-220-8 electronic component of Sola 63-23-220-8

Power Conditioning 2000VA 120-240V OUT
Stock : 4

63-23-650-8 electronic component of Sola 63-23-650-8

Surge Suppressors Three Phase 50Hz
Stock : 2

23-23-150-8 electronic component of Sola 23-23-150-8

Power Conditioning 500VA 120V 240V OUT
Stock : 13

A301-150-B2 electronic component of Mean Well A301-150-B2

Power Inverters 150W 110Vout 15A 12V MODIFIED SINE WAVE
Stock : 7

63-23-650-8 electronic component of Solahd 63-23-650-8

Power Conditioning 500VA MCR HW REGULATOR 50Hz
Stock : 0

63-13-070-6 electronic component of Sola 63-13-070-6

Power Conditioning 70VA 120V In/Out
Stock : 0

Power Protection and Conditioning MCR Portable Series Power Line Conditioning with Voltage Regulation The MCR provides excellent noise filtering and surge protection to protect connected equipment from damage, degradation or misoperation. Combined with the excellent voltage regulation inherent to SolaHDs ferroresonant design, they can increase the actual Mean Time Between Failure (MTBF) of protected equipment. These units are a perfect choice where dirty power caused by impulses, swell, sags, brownouts and waveform distortion can lead to costly downtime because of damaged equipment. Applications E47379 LR044950 Computers/ Printers Telephone/FAX systems Certifications and Compliances POS terminals All Models Security systems RoHS Compliant Laboratory equipment LAN networks Listed Features - UL 1012 3% output voltage regulation Select Models Noise attenuation - 120 dB common mode Listed (1500VA Units) - 60 dB transverse mode - UL 1012, CSA C22.2 No. 66 Surge protection tested to ANSI/IEEE C62.41 Class A & B waveform (<10 V let-through typical) Certified (70VA-1kVA Units) Harmonic filtering - CSA C22.2 No. 66 Galvanic isolation provides exceptional circuit protection. Related Products Point-of-use protection (cord & plug connected) DIN Rail AC UPS (SDU) - Easy & Flexible Installation Off-Line UPS (S1K Mini-Tower) 25 year typical MTBF Line-Interactive UPS (S3K Mini-Tower) No maintenance required Selection Tables: Single Phase Group A MCR Portable Series, 60 Hz Catalog Voltage Height Width Depth Ship Weight Receptacle (No.) Plug VA Number Input/Output in (mm) in (mm) in (mm) lbs (kg) Type (NEMA) (NEMA) 70 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 18.0 (8.16) (4) 5-15R 5-15P 63-13-070-6 150 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 21.0 (9.53) (4) 5-15R 5-15P 63-13-115-6 250 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 26.0 (11.79) (4) 5-15R 5-15P 63-13-125-6 500 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 32.0 (14.51) (4) 5-15R 5-15P 63-13-150-6 750 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 64.0 (29.03) (4) 5-15R 5-15P 63-13-175-6 1000 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 69.0 (31.30) (4) 5-15R 5-15P 63-13-210-6 1500* 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 95.0 (43.09) (6) 5-15R 5-20P 63-13-215-6 2000 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 115.0 (52.16) (4) 5-15R, (1) L5-30R L5-30P 63-13-220-6 3000* 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 143.0 (64.86) (4) 5-15R, (1) L5-30R 5-50P 63-13-230-6 * * Only Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 48 January 2017Power Protection and Conditioning Specifications Parameter Condition Value Input Continuous at full load (lower input voltage possible at lighter load) +10% to -20% of nominal Voltage For temporary surge or sags +20% to -35% of nominal 1 At Full Load & 80% of nominal input voltage I (VA/.89)/(V x 80%) Current in in See Operating Characteristics section for details. 60 Hz depending on model Frequency 1 Output V >80% and <110% of nominal Line Regulation 3% for 60 Hz units in At Nominal Input Voltage Current limited at 1.65 times rated current Overload Protection At full load within input range 3% total RMS content Output Harmonic Distortion -Common Mode 120 dB Noise Attenuation -Transverse Mode 60 dB ANSI/IEEE C62.41 Class A & B Waveform <10V typical Let-Through General At Full Load 92% Typical Efficiency Humidity <95% non-condensing -20 to +85C Storage Temperature Humidity <95% non-condensing -20 to 40C Operating Temperature Full Resistive Noise 35 dBA to 65 dBA Audible Noise 10 + 2 year limited warranty Warranty Notes: 1 - It is recommended that the unit run at a minimum of 40-50% load. Back Panels Plug & Receptacle Reference Chart 5-15R 5-15P L5-30P 60 Hz, 20003000 VA, 60 Hz, 70 1000 VA, (4) 5-15R and (1) (4) 5-15R Receptacles L5-30R Receptacle Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 49 January 2017

Tariff Desc

8543.70.00 - ELECTRICAL MACHINES AND APPARATUS, HAVING INDIVIDUAL FUNCTIONS, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER: Other machines and apparatus Free
91 .. Other
Sola Hevi-Duty
Sola / Hevi-Duty
Sola/Hevi-Duty
SOLA-IC

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted