Product Information

E3H30S

E3H30S electronic component of Sola

Datasheet
Industrial Control Transformers 30KVA 208D-208Y

Manufacturer: Sola
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Availability Price Quantity
0 - Global Stock


Multiples : 1

Stock Image

E3H30S
Sola

N/A

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Power Rating
Primary Voltage Rating
Secondary Voltage Rating
Secondary Current Rating
Mounting Style
Primary Winding
Secondary Winding
Length
Width
Height
Operating Frequency
Product
Series
Type
Brand
Product Type
Factory Pack Quantity :
Subcategory
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
E500 electronic component of Sola E500

Industrial Control Transformers 0.500KVA 240X480-120 W/ FB2X
Stock : 5

E500TF electronic component of Sola E500TF

Industrial Control Transformers 0.5KVA 208/240/ 415/480/600-120
Stock : 5

E500TH electronic component of Sola E500TH

Industrial Control Transformers 0.500KVA 240/415/ 480-120/240
Stock : 0

E500TC electronic component of Sola E500TC

Industrial Control Transformers 0.500KVA 208/ 240/415-120/24
Stock : 0

E500JN electronic component of Sola E500JN

Industrial Control Transformers 0.5KVA 208/240/480/ 600-120/24
Stock : 3

E500E electronic component of Sola E500E

Industrial Control Transformers 0.500KVA 120X240-24
Stock : 0

E500D electronic component of Sola E500D

Industrial Control Transformers 0.500KVA 240X480-24
Stock : 0

E500JL electronic component of Sola E500JL

Industrial Control Transformers 0.500KVA 208/240/ 277-120/24
Stock : 0

E500TE electronic component of Sola E500TE

Industrial Control Transformers 0.5KVA 208/ 240/277/415/480-24
Stock : 10

E500EWB electronic component of Sola E500EWB

Industrial Control Transformers E500E+FBPC1+ FB2X FACTORY WIRED
Stock : 0

Image Description
E81H30S electronic component of Sola E81H30S

Industrial Control Transformers LVGP 2016 XMFR 30KVA 480D-480Y
Stock : 0

E84H75S electronic component of Sola E84H75S

Industrial Control Transformers 75KVA 208D-480Y
Stock : 0

E79H45S electronic component of Sola E79H45S

Industrial Control Transformers LVGP DOE2016 45KVA 480D-380Y
Stock : 0

HS14F1CSCE electronic component of Sola HS14F1CSCE

Industrial Control Transformers 1KVA 190//440- 110/220 50/60 CE
Stock : 0

2520 electronic component of Staco 2520

Industrial Control Transformers Single, 10A, Manual 240V/480Vin, 560Vout
Stock : 2

3PN1510B electronic component of Staco 3PN1510B

Industrial Control Transformers Single, 15A, Plug 0-120Vin/140Vout
Stock : 4

3PN221B electronic component of Staco 3PN221B

Industrial Control Transformers Single, 2.5A, Plug 0-120Vin, 0-132Vout
Stock : 0

501C electronic component of Staco 501C

Industrial Control Transformers Single, 5A, Manual 0-120Vin/140Vout
Stock : 17

808-0128-S electronic component of Staco 808-0128-S

Variable Transformers Brush for use with 501 Series.
Stock : 3

808-0129-S electronic component of Staco 808-0129-S

Brush Assy
Stock : 2

Dry Type Distribution Transformers General Purpose Energy efficient dry-type SolaHD General Purpose Transformers 600 Volt Class, isolation type, single and three phase, 15 kVA through 500 kVA. Indoor and outdoor models available. For catalog numbers outside of the standard Selection Tables, fill out the Custom Transformer Quotation Request at the end of this section. Accessories and Optional Design Styles Electrostatic shield for quality power Wall mounting brackets (500 lbs maximum) (Item WB1C) Energy Verified Rendement nergtique Vrifi Weather Shields (UL Listed/NEMA Type 3R) E25872 EV33981 Stainless Steel Enclosures Terminal board connections and spacious wiring Totally enclosed non-ventilated designs * compartment Open core and coil designs (UL Recognized) Panel enclosure design reduces labor time. Wiring Copper Wound designs diagram on inside front cover. Low temperature designs High efficiency for low cost operation Single and three phase availability Features Fast delivery Energy Efficient Compliant to DOE 2016/NRCan 2019 as 1 applicable Meets transit test requirements for ISTA (International Safe Transit Association) Test Procedure UL Listed/NEMA Type 3R ventilated outdoor enclosures 1E for packaged-product when used with optional weather shields (order separately) 10 year limited warranty UL Class 220C insulation system, 150C Certifications and Compliances temperature rise under full load Listed: E25872 Quiet operation with sound levels 3-6 dB below the - UL 1561/CSA C22.2 No. 47 NEMA ST-20 requirements Energy Verified Rendement nergtique Vrifi CSA No. 802.2-18 Selection Tables: Single Phase Group 1: 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz Catalog Type 3R Height Width Depth Approx. Ship Weight Design Elec Primary Secondary kVA 2 3 3 Number in (mm) in (mm) in (mm) lbs (kg) Amps Amps Weather Shield Style Conn 15 28 (711) 16 (406) 16 (406) 210 (95) 1 1 62.5/31.3 125/62.5 ES5H15S WS-15 25 28 (711) 16 (406) 16 (406) 245 (111) 1 1 104/52.1 208/104 ES5H25S WS-15 37.5 31 (787) 18 (457) 18 (457) 340 (154) 1 1 156/78 313/156 ES5H37S WS-17 50 31 (787) 18 (457) 18 (457) 415 (188) 1 1 208/104 416/208 ES5H50S WS-17 75 44 (1118) 23 (584) 21 (533) 610 (277) 1 1 313/156 625/313 ES5H75S WS-09 100 44 (1118) 23 (584) 21 (533) 705 (320) 1 1 417/208 833/417 ES5H100S WS-09 167 46 (1168) 26 (660) 24 (610) 980 (445) 1 1 695/348 1392/695 ES5H167S WS-16 Group 2 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Weight Primary Amps Secondary kVA 2 3 3 Number in (mm) in (mm) in (mm) lbs (kg) 277 V Amps Weather Shield Style Conn 15 28 (711) 16 (406) 16 (406) 215 (98) 1 2 54.2 125/62.5 ES12H15S WS-15 25 28 (711) 16 (406) 16 (406) 250 (113) 1 2 90.3 208/104 ES12H25S WS-15 Notes: 2. Weather shields (set of two) must be ordered separately. 1. DOE 2016 refers to Department of Energy CFR (Code of Federal 3. Design Styles and Electrical Connections can be found at the end of the Regulations) title 10, part 431.196. NRCan 2019 refers to Natural Resources Ventilated Distribution Transformers section. Canada CSA C802.2, Minimum Efficiency Values for Dry-Type Transformers. * Not all optional designs are listed. Contact Technical Services. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 198 April 2019Dry Type Distribution Transformers Selection Tables: Three Phase Group A: 480 Volt Primary, 208Y/120 Secondary, 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Weight Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) lbs (kg) Amps Amps Weather Shield Style Conn 3 E2H15 15 23 (584) 18 (457) 14 (356) 221 (100) 1 5 18.1 41.7 WS-02 E2H15S 3 E2H30 30 28 (711) 23 (584) 16 (406) 310 (141) 1 5 36.1 83.4 WS-14 E2H30S 3 E2H45 45 28 (711) 23 (584) 16 (406) 387 (176) 1 5 54.2 125 WS-14 E2H45S 3 E2H75 75 34 (864) 28 (711) 22 (559) 678 (308) 1 5 90.3 208 WS-30 E2H75S 112.5 34 (864) 28 (711) 22 (559) 794 (360) 1 5 135 313 E2H112S WS-30 150 44 (1118) 33 (838) 21 (533) 1005 (456) 1 5 181 417 E2H150S WS-10 225 46 (1168) 36 (914) 24 (610) 1368 (621) 1 5 271 625 E2H225S WS-11 300 46 (1168) 36 (914) 24 (6010) 1479 (671) 1 5 361 834 E2H300S WS-11 500 65 (1651) 45 (1143) 35 (889) 2457 (1114) 1 5 602 1390 E2H500S WS-12 4 Group B: 480 Volt Primary, 240 Volt Secondary with 120 V reduced capacity center tap , 60 Hz Catalog Type 3R Height Width Depth Approx. Ship Weight Design Elec Primary Secondary kVA 1 2 2 Number Weather Shield in (mm) in (mm) in (mm) lbs (kg) Style Conn Amps Amps 3 E5H15 15 23 (584) 18 (457) 14 (356) 221 (100) 1 6 18.1 36.1 WS-02 E5H15S 3 E5H30 30 28 (711) 23 (584) 16 (406) 322 (146) 1 6 36.1 72.3 WS-14 E5H30S 3 E5H45 45 28 (711) 23 (584) 16 (406) 387 (176) 1 6 54.2 108 WS-14 E5H45S 3 E5H75 75 34 (864) 28 (711) 22 (559) 678 (308) 1 6 90.3 181 WS-30 E5H75S 112.5 34 (864) 28 (711) 22 (559) 792 (359) 1 6 135 271 E5H112S WS-30 150 44 (1118) 33 (838) 21 (533) 1009 (458) 1 6 181 361 E5H150S WS-10 225 46 (1168) 36 (914) 24 (610) 1367 (620) 1 6 271 542 E5H225S WS-11 300 46 (1168) 36 (914) 24 (610) 1478 (670) 1 6 361 723 E5H300S WS-11 500 65 (1651) 45 (1143) 35 (889) 2457 (1114) 1 6 602 1204 E5H500S WS-12 Notes: 1. W eather shields (set of two) must be ordered separately. 2. Design Styles and Electrical Connections can be found at the end of the Ventilated Distribution Transformers section. 3. Unshielded model. 4. Refer to Capacity of Center Tap in Center Tap Delta Transformers at the beginning of this section. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. 199 April 2019

Tariff Desc

8504.31.00 TC9500870 TRANSFORMERS, output, ferrite core, frequency within the range 20-50KHz, nominal power rating NOT greater than 100W

8504.31.00 TC1224368 TRANSFORMERS, LED, NOT less than 24VDC and NOT greater than 35VDC

8504.40.30 as follows
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 Electric current rectifying assemblies
Free

8504.31.00 TC702370 TRANSFORMERS, CURRENT AND/OR VOLTAGE, having ANY of the following
(a) current transformer voltage rating GREATER than 400kV
(b) voltage transformer voltage rating GREATER than 72kV
(c) combined current and voltage transformer voltage rating GREATER than 72kV

8504.34.00 TC513212 TRANSFORMERS, having ALL of the following
(a) primary and secondary winding
(b) primary voltage NOT less than 500kV
(c) greater than 330 MVA rating

8504.31 TC8343084 AUTOTRANSFORMERS, toroidal core, continuously variable from zero voltage

8504.31 TC8343083 TRANSFORMERS, radio frequency, power rating 100W continuous, frequency range 1.4MHz or greater but NOT exceeding 200.0MHz, input impedance 75ohms, output impedance 50ohms

8504.33.00 TC1761475 CURRENT TRANSFORMER MODULES, with OR without voltage measurement outputs, having NOT greater than 4 poles

8504.31.00 TRANSFORMERS, RF pulse, dual in-line packaging (DIP) TC9209172

8504.31.00 TC 1056338 TRANSFORMERS, TOROIDAL, STEP DOWN, isolated OR auto-wound, enclosed, complying with Australian & NZ Standards AS/NZS61558.1:2008, AS/NZS3820:2009 & AS/NZS3191:2008, including ALL of the following
(a) input voltage NOT less than 230V and NOT greater than 250V
(b) output voltage NOT less than 100V and NOT greater than 120V
(c) female 3 slot output chassis sockets rated at NOT greater than 20A
(d) rated Voltage Amps NOT less than 0.05kVA & NOT greater than 4kVA
(e) thermal fuse or thermal cut out protectors
Sola Hevi-Duty
Sola / Hevi-Duty
Sola/Hevi-Duty
SOLA-IC

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted