Product Information

OXY-FLEX-1-H

OXY-FLEX-1-H electronic component of SST Sensing

Datasheet
Air Quality Sensors 25% 100% range Oxygen sensor +400degC 400mm probe digitalanalogue outputs

Manufacturer: SST Sensing
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 1199.3625 ea
Line Total: USD 1199.36

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Thu. 23 May to Mon. 27 May

MOQ : 1
Multiples : 1

Stock Image

OXY-FLEX-1-H
SST Sensing

1 : USD 1138.4425
10 : USD 1127.6325

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Type
Operating Supply Voltage
Maximum Operating Temperature
Minimum Operating Temperature
Current Rating
Output Voltage
Brand
Sensor Type
Product Type
Factory Pack Quantity :
Subcategory
Supply Voltage - Max
Supply Voltage - Min
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
KGZ12 electronic component of SST Sensing KGZ12

Air Quality Sensors Oxygen Sensor zirconia 250 degC max 3bar ppO2 420mm probe <15s response
Stock : 0

O2S-FR-T2 electronic component of SST Sensing O2S-FR-T2

Air Quality Sensors Oxygen Sensor zirconia 250 degC max 3bar ppO2 220mm probe <4s response
Stock : 10

ZrO2-System-485 electronic component of SST Sensing ZrO2-System-485

Air Quality Sensors Oxygen Sensor System zirconia 0.1 to 100% O2 RS485 Modbus RTU output
Stock : 10

ZrO2-System-A25 electronic component of SST Sensing ZrO2-System-A25

Air Quality Sensors Oxygen Sensor System zirconia 0.1 to 25% O2 with 4-20mA output
Stock : 22

ZrO2-System-V25 electronic component of SST Sensing ZrO2-System-V25

Air Quality Sensors Oxygen Sensor System zirconia 0.1 to 25% O2 with 0-10VDC output
Stock : 12

OXY-LC-A25-455 electronic component of SST Sensing OXY-LC-A25-455

Air Quality Sensors Oxygen Sensor Interface
Stock : 4

OXY-LC-485 electronic component of SST Sensing OXY-LC-485

Air Quality Sensors Zirconia sensor control electronics
Stock : 5

O2S-FR-T2-18BM-C electronic component of SST Sensing O2S-FR-T2-18BM-C

Air Quality Sensors Zirconia Oxygen Sensor
Stock : 10

POS12BSP electronic component of SST Sensing POS12BSP

Screws & Fasteners Optional Weld Nut
Stock : 0

O2S-FR-T2-18BM-A electronic component of SST Sensing O2S-FR-T2-18BM-A

Air Quality Sensors Zirconia Oxygen Sensor
Stock : 6

Image Description
MR003-005.1 electronic component of Microbot MR003-005.1

Sensor: humidity sensor; Interface: analog
Stock : 0

GMS10RVS electronic component of Honeywell GMS10RVS

Air Quality Sensors OXYGEN SENSOR 4V 40UA
Stock : 0

MAGNETIC SWITCH electronic component of Seeed Studio MAGNETIC SWITCH

Sensor: magnetic field; switch; 4.75÷5.25VDC; IC: CT10; Grove
Stock : 0

OKY3334 electronic component of OKYSTAR OKY3334

Sensor: gas level; 5VDC; MQ-7; CO; Resolution:10÷1000ppm
Stock : 0

EC4-1000-H2S electronic component of Amphenol EC4-1000-H2S

Air Quality Sensors 4 series H2S gas sensor 1000ppm
Stock : 0

OKY3072-1 electronic component of OKYSTAR OKY3072-1

Sensor: atmospheric; temperature, humidity; digital; 5VDC
Stock : 0

OKY3339 electronic component of OKYSTAR OKY3339

Sensor: air quality; 5VDC; MQ-135; alcohol, benzene, smoke
Stock : 0

T5100-V electronic component of Amphenol T5100-V

Air Quality Sensors Wallmount CO2 Sensor
Stock : 1

USEQGCCACH4100 electronic component of Kemet USEQGCCACH4100

Air Quality Sensors Gas Detector Sensor Analog TO-39
Stock : 1

SGX-7H2S-200 electronic component of Amphenol SGX-7H2S-200

Air Quality Sensors 7 Series H2S sensor fixed apps-100ppm
Stock : 0

DATA SHEET Zirconia O Sensors 2 OXY-Flex Oxygen Analyser FEATURES High accuracy linear output Externally triggered automatic or manual calibration Can be calibrated in fresh air (20.7% O ) or to any 2 other known O concentration 2 Selectable output filtering allows adaptive, fast and dynamic or slow and stable output Housing Supply Gas Temp Digital Analogue Response Voltage Output Output Time BENEFITS OUTPUT VALUES 2 1 Oxygen range (analogue output) 0.1 25% O 2 Cycling 3.3V logic output allows direct monitoring of the DC 1 or 0.1 100% O 2 O sensor pump cycle for diagnostic purposes 2 1 Oxygen range (RS232 output) 0.1 and 100% O 2 No reference gas required 3, 4 Accuracy after calibration 1% O 2 3 Repeatability after calibration 0.5% O 2 Output resolution TECHNICAL SPECIFICATIONS Analogue 420mA 0.01mA Supply voltage 24V 10% Analogue 010V 0.01V DC DC Supply current 500mA max. at 24V Digital RS232 0.01% O DC 2 Digital output RS232 Response time < 15s Analogue output 420mA load 600 max. Warm up time (prior to sensor operation) 60s or 010V load 10k min. Output stabilisation time ~ 180s DC Housing temperature limits Storage: -10C to +85C Operating: -10C to +85C Permissible gas temperatures (probe tip) Need help Ask the expert Standard: -100C to +250C Tel: + 44 (0)1236 459 020 High: -100C to +400C and ask for Technical Gas flow rate 0 to 10 m/s Permissible acceleration Repetitive 5g Incidental 30g 1) Prolonged operation below 0.1% O can damage the sensing element. 2 2) Range selectable by altering the position of the jumper links on the PCB refer to PCB Layout on page 3. NOTES 3) Assuming barometric pressure (BP) remains constant. 4) As the O sensor measures the partial pressure of oxygen (PPO ) within the measurement gas deviations in the BP from 2 2 that present during calibration will cause readout errors proportional to the change. EG. if the sensor reads 21% O at 2 1013.25mbar and the BP increases by 1%, the sensor readout will also increase by 1% to 21.21% O . 2 OUTLINE DRAWING AND MOUNTING INFORMATION All dimensions shown in mm. Tolerances = 1mm.

Tariff Desc

8543.70.00 - Other machines and apparatus Free
13 No Signal processors (graphic equalisers, crossovers etc.)
91 .. Other

9027.10.00 Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes.

9031.80.00 - MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free
SST Sensing
SST Sensing Ltd

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted