Product Information

GSD-1000

GSD-1000 electronic component of Stancor

Datasheet
Autotransformers Auto 230V/115V

Manufacturer: Stancor
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 245.4244 ea
Line Total: USD 245.42

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Thu. 02 May to Wed. 08 May

MOQ : 1
Multiples : 1

Stock Image

GSD-1000
Stancor

1 : USD 245.4244
5 : USD 220.8806
10 : USD 200.7994
25 : USD 193.7513
50 : USD 175.2975

0 - Global Stock


Ships to you between Thu. 02 May to Wed. 08 May

MOQ : 1
Multiples : 1

Stock Image

GSD-1000
Stancor

1 : USD 296.5671

0 - Global Stock


Ships to you between Thu. 02 May to Wed. 08 May

MOQ : 1
Multiples : 1

Stock Image

GSD-1000
Stancor

1 : USD 282.5641

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Power Rating
Primary Voltage Rating
Mounting Style
Length
Width
Height
Number Of Outputs
Operating Temperature Range
Product
Termination Style
Type
Brand
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
STC-180 electronic component of Stancor STC-180

Disc Thermostat (Snap-Action), Contact Voltage 120/240, Temp
Stock : 0

STC-240 electronic component of Stancor STC-240

Disc Thermostat (Snap-Action), Contact Voltage 120/240, Temp
Stock : 0

STO-230 electronic component of Stancor STO-230

Snap Action Disc Thermostat 4-Pin
Stock : 196

SW-356 electronic component of Stancor SW-356

Power Transformers Printed Circuit Transformer "Side-Winder", Input Voltage: 120 VAC, Output Voltage: 28.0 VAC, Output Amperage: 45mA
Stock : 381

TTPC-13 electronic component of Stancor TTPC-13

Emerson Impedance Matching Transformer (Telephone Coupling) Impedance: Primary 15% 600, Secondary 10% 600 C.T. Split, D.C. Curr. mA. 90, Insertion Losses db Max at 1 KHz 1.8, Primary DCR 73
Stock : 571

TTPC-7 electronic component of Stancor TTPC-7

Power Transformers Impedance Matching Transformer (Telephone Coupling), Input Impedance: 600 Ohms, Output Impedance: 600 Ohms, D.C. Current: 0mA
Stock : 500

STO-190 electronic component of Stancor STO-190

Snap Action Disc Thermostat 4-Pin
Stock : 0

TTPC-8 electronic component of Stancor TTPC-8

Emerson Impedance Matching Transformer (Telephone Coupling) Impedance: Primary 15% 600 C.T., Secondary 10% 600, D.C. Curr. mA. 0, Insertion Losses db Max at 1 KHz 1.2, Primary DCR 36
Stock : 0

STC-120 electronic component of Stancor STC-120

Snap Action Disc Thermostat 4-Pin
Stock : 0

ST301S09015 electronic component of Stancor ST301S09015

ST301S09015 stancor
Stock : 39

Image Description
168B electronic component of Hammond 168B

hard wired line autotransformers
Stock : 1

168E electronic component of Hammond 168E

Autotransformers 750VA LINE ADJ AUTO
Stock : 1

170E electronic component of Hammond 170E

Autotransformers 230/115V 750 VA
Stock : 0

ARM-5.0/1 electronic component of Breve Tufvassons ARM-5.0/1

Variable autotransformer; 230VAC; 5A; 2.6kg
Stock : 8

TS90-230V/115V-002 electronic component of Indel TS90-230V/115V-002

Autotransformer; 230VAC; Power:90VA; Usec.1:115V
Stock : 1

176D electronic component of Hammond 176D

Autotransformers Plug-In/Step-Up Auto 500VA, 115-230VAC
Stock : 2

170D electronic component of Hammond 170D

Wire Stripping & Cutting Tools Xcelite Shearcutter 5" Stat Disap Grips
Stock : 1

N-11MG electronic component of Triad N-11MG

Autotransformers POWER AUTO-XFMR 115V@17.4A 230V CHASSIS MOUNT w/AC GROUND CORD & SOCKET
Stock : 1

N-7M electronic component of Triad N-7M

Autotransformers Power Transformer, AutoTransformer, 230/115VAC, 600 V A Rating, Step-Up/Step-Down
Stock : 1

TST 150-230V/115V-002 electronic component of Indel TST 150-230V/115V-002

Autotransformer; 230VAC; Power:150VA; Usec.1:115V
Stock : 1

Au TO / i S O l AT i O N T R A N S F O R M E R S Step-Down, Step-Up and Isolation Transformers Auto/Isolation Transformers Isolation Transformers have two (2) separate windings with an elec- trostatic shield between them to provide complete electrical isolation from the source. style A Auto Transformers have one (1) winding that is tapped to achieve specific output voltage. They provide no electrical isolation in a circuit. style c Auto Transformers are typically smaller than their Isolation equivalent. See Accessories, pages 40-41, for International Adapter Plugs Designed for 50/60 Hertz sTAnco R Rms DImens Ions -Inches PART Voltage Input output Test case mounting Weight Agency sec. nUmBeR Type step Voltage Voltage Amps V.A. c ap. Voltage style h W D mW mD (lbs.) certif. A P-6287 Auto Down 230 115 0.35 40 1500 C 3.13 2.50 2.75 2.00 1.75 2.20 P-8620 Auto Down 230 115 0.43 50 1500 A 2.31 3.69 1.88 3.13 - 1.50 - GSD-75 Auto Down 230 115 0.65 75 1500 C 3.13 2.50 2.88 2.00 1.75 3.00 - P-8630 Auto Down 230 115 0.74 85 1500 C 3.13 2.50 2.88 2.00 1.75 2.50 - GSD-100 Auto Down 230 115 0.87 100 1500 C 3.13 2.50 3.13 2.00 2.06 3.70 - B P-8631 Auto Down 230 115 1.10 125 1500 C 3.13 2.50 3.00 2.00 2.06 3.00 - GSD-150 Auto Down 230 115 1.30 150 1500 C 3.88 3.13 3.25 2.50 2.22 4.40 - P-8632 Auto Down 230 115 1.74 200 1500 C 3.88 3.13 3.25 2.50 2.22 4.20 - GSD-250 Auto Down 230 115 2.20 250 1500 C 3.88 3.13 3.63 2.50 2.22 5.80 - GSD-300 Auto Down 230 115 2.60 300 1500 C 3.88 3.13 3.63 2.50 2.22 5.80 - C GSD-350 Auto Down 230 115 3.00 350 1500 C 3.88 3.13 4.31 2.50 2.72 7.30 - P-8634 Auto Down 230 115 3.50 400 1500 C 3.88 3.13 4.25 2.50 2.72 7.00 - GSD-500 Auto Down 230 115 4.30 500 1500 C 4.63 3.81 4.44 3.00 3.19 10.6 - GSD-750 Auto Down 230 115 6.50 750 1500 C 4.63 3.81 5.38 3.00 3.94 14.4 - GSD-1000 Auto Down 230 115 8.70 1000 1500 C 4.63 3.81 6.06 3.00 4.69 17.0 - GSD-1500 Auto Down 230 115 13.0 1500 1500 C 5.38 4.44 6.00 3.50 4.00 20.0 - D P-8638 Auto Up 115 230 0.54 125 1500 C 3.13 2.50 3.00 2.00 2.06 3.00 - P-8639 Auto Up 115 230 1.30 300 1500 C 3.88 3.13 3.88 2.50 2.22 5.20 - P-8640 Auto Up 115 230 2.17 500 1500 C 4.63 3.75 4.50 3.00 3.19 10.3 - P-8689 Auto Up 115 230 4.35 1000 1500 C 4.63 3.75 6.13 3.00 4.69 17.0 - E P-6413 Isolation Straight 115 115 0.005 0.60 1500 A 1.25 2.13 1.25 1.75 - 0.25 - P-6411 Isolation Straight 115 115 0.13 15 1500 A 2.00 3.25 1.88 2.81 - 1.00 - P-6412 Isolation Straight 115 115 0.30 35 1500 A 2.31 3.75 2.00 3.13 - 1.70 - P-6410 Isolation Straight 115 115 0.43 50 1500 C 3.50 2.81 3.50 2.25 2.00 3.70 - F P-8622 Isolation Straight 115 s115/230 1.30 150 1500 C 3.88 3.13 4.00 2.50 2.72 6.20 - P-6406 Isolation Straight 115/230* 115 0.43 50 1500 A 2.38 3.75 2.31 3.13 - 1.80 - G GIS-100 Isolation Straight 115 115 0.87 100 1500 C 3.50 2.81 3.56 2.25 2.28 4.50 - GIS-150 Isolation Straight 115 115 1.30 150 1500 C 3.88 3.13 4.19 2.50 2.72 7.00 - GIS-250 Isolation Straight 115 115 2.17 250 1500 C 4.69 3.75 4.38 3.00 3.19 9.00 - GIS-500 Isolation Straight 115 115 4.35 500 1500 C 4.69 3.75 6.00 3.00 4.69 16.0 - GIS-1000 Isolation Straight 115 115 8.70 1000 1500 C 5.38 4.38 8.13 3.50 6.50 31.0 - H GISD-100 Isolation Down 230 115 0.87 100 1500 C 3.50 2.81 3.63 2.25 2.28 4.50 - GISD-150 Isolation Down 230 115 1.30 150 1500 C 3.88 3.13 4.19 2.50 2.72 7.00 - GISD-250 Isolation Down 230 115 2.17 250 1500 C 4.69 3.75 4.38 3.00 3.19 9.00 - GISD-500 Isolation Down 230 115 4.35 500 1500 C 4.69 3.75 6.00 3.00 4.69 16.0 - GISD-1000 Isolation Down 230 115 8.70 1000 1500 C 5.38 4.38 8.13 3.50 6.50 31.0 - Has electrostatic shield on separate leadwire (not grounded) For outline drawings refer to page 39 s Secondary is two separate 115 volt windings can be wired independently Has lead wires * Primary is two separate 115 volt windings www.stancor.com Au TO / i S O l AT i O N T R A N S F O R M E R S Step-Down, Step-Up and Isolation Transformers Style C Style A d G E N E R A L I N F O R M A T I O N motor which is somewhat higher than the running current. This information is generally available from the appliance manufacturer. Information pertaining standard length of the input and output cords: to the AC Wattage or current required by an appliance is generally marked 1 Input Cord = 5 /2 Feet minimum on the item by the manufacturer and should be observed. It is much better to Output Cord = 8 Inches minimum buy a transformer with a larger VA rating than you will actually need because of larger motor starting currents and variations in the line voltage and/or fre- Auto/Isolation Transformers can be used in most countries by using quency in some locations, which could cause overheating. an input adapter plug. See page 40 for STANCORs high quality line of International Adapter Plugs. Isolation Transformers Used where a direct connection between primary and secondary circuits is W H y & W H E R E A U T O & I S O L A T I O N not desired and the circuits must be isolated. This results in a larger, heavier T R A N S F O R M E R S A R E U S E D and more costly item for a given power rating. However, in addition to the Stancors stock Auto Transformers are connected for either step-down or isolating advantages, an electrostatic shield is generally added to minimize step-up applications involving line voltages of 115 or 230 Volts., 50/60 Hertz. capacitive coupling between primary and secondary circuits. This helps to When isolation between the primary and secondary circuits is not necessary, minimize the transfer of unwanted power line transients and interference and a direct connection between them is permissible, the Auto Transformer from other sources connected to the power line by capacitive coupling to the offers the advantages of smaller size, less weight, and lower cost. secondary circuit. The standard insulation test voltage rating between wind- This type of unit is generally used in applications involving American appli- ings and between each winding and the core is 1,500 Volts R.M.S. This is ances used abroad where our standard 115 Volt equipment must operate from normally sufficient for 115 and 230 Volt operation. a 230 Volt source. It is also used for foreign appliances designed for 230 Volt The VA rating should be selected for each specific application, with allow- operation, which are to be used on our 115 Volt circuits. Our catalog items ance for any abnormal load or environmental conditions. All catalog items are designed for continuous rated output on either 50 or 60 Hertz. have an operating temperature of 105 Degrees C. (Designed for a 65 Degrees It is important to bear in mind that the Auto/Isolation C. maximum temperature rise above a maximum ambient temperature for 40 Transformers change only the voltage levels and do not change Degrees C., with unrestricted free air ventilation.) V-A/Amps output ratings are the frequency from 50 to 60 h ertz or vice versa. In appliances for continuous operation from the specified input voltage and frequency. using synchronous motors, such as clocks or phonograph record General Information changers and players, the speed will be different when using them All of these items have Class A insulation and are rated to have a maximum on a frequency which differs from the frequency they were origi- operating temperature of 105 Degrees C. These units may be used with nally designed. In these cases the manufacturer of the appliance rectifiers but the form factor as explained elsewhere in this catalog should should be consulted to obtain the proper motor. be observed for various combinations of rectifier circuits and types of load The VA rating is equivalent to a Wattage rating where a resistive load and/ following the rectifier. or unity power factor exists. When inductive loads such as motors are used These items are made with our standard N.E.M.A. plugs and receptacles, (as in a motor driven appliance) the power factor is not unity and to be accu- primarily for use in this country. However, if used overseas where different rate the output is expressed in VA, which is the product of the output voltage types of plugs are necessary, an adapter plug should be used or our plug and the output current (Amps). removed and a foreign plug attached to the end of the line cord. When selecting one of these items for use with an appliance which includes a motor, allowance should be made for the starting current of the www.stancor.com 

Tariff Desc

8504.32 AUTOTRANSFORMERS, toroidal core, continuously variable from zero voltage Op. 01.01.1988 Dec. 01.01.1988 - TC 8734825

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted