Switch Mode Power Supply Model AAD600S Highly Accelerated 600 Watts output power max H . A . L . T. Life Power Factor Correction TESTED Testing Single Output Electrical Specifications Input Voltage: 85-264 VAC, 47-63 Hz Input Current: <6.5A RMS 115 VAC full load <3.5A RMS 230 VAC full load 9.0A RMS 85 VAC full load Inrush Current: <20A, pk 110 VAC, active soft start <40A, pk 220 VAC, active soft start (Active independant of cold or warm start) Power Factor: >0.99 full load 230VAC input Harmonic Distortion: Meets IEC1000-3-2 EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15 Class B (conducted) Input Protection: Internal AC line fuse 250 VAC, 10A Output Power: Up to 600W continuous AC Power Fail: TTL logic 0 at least 2 ms before DC LOW output drops 5% (without signal jitter). Line Regulation: 0.1% Open collector. Load Regulation: 0.25% DC OK: Open collector when output voltage is above P ARD: <1% or 250mV 95% of rated 20MHz bandwidth Overcurrent/Short Circuit: Square current limit 105-130% of rated Time: >16 ms full load Hold-up Overvoltage Protection: Factory set, 125% 5% Output Polarity: Output is floating cycle AC to reset Minimum Load: None Reverse Voltage: Reverse current up to rated outputs Transient Response: 2% for 25% load change 1A/s Thermal Protection: Auto off auto reset upon cool down Output Rise Time: <100 ms (10% to 90%) Efficiency: Up to 92% Remote Sense: Standard MTBF: MIL-STD-HDBK 217E 200,000 hours 25C, ground benign, Current Share: Within 5% Highly Accelerated Life Testing Remote On/Off: Ground or TTL = OFF LOW Open or TTL = ON HIGH Available Voltage Outputs* Continuous Voltage Voltages Current Codes (Volts) (Amps) -4 12 42 -5 15 36 -6 24 23 -7 28 20 -8 36 16 -9 48 12.5 * Consult factory for other voltages and OEM quantities. Note: Standard models are shown bold PART STRUCTURE: MODEL - VOLTAGE CODE - OPTION CODES (See back) - V1 - AAD600S - X - ABC.... Example: Part Number AAD600S-8-CF = 600W Power Factor Corrected, 36V 16A with sealed pots and overcurrent foldback mode. SEE 3rd PAGE FOR THE AAD600S CODE TABLE AND AVAILABLE OPTIONS. Model AAD600S Options (code) Surge & ESD Test Levels DC OK Invert (U) PF Invert (B) EN61000-4-5 Level 3 EN61000-4-2 Level 2 Metric Mounting (M) Remote On/Off Invert (S) EN61000-3-2 EN61000-4-2 Level 3 (Air Only) OR-ing Diodes (O) Overcurrent Hiccup Mode (D) EN61000-4-4 Level 3 EN61000-4-11 Droop Current Share (A) Overcurrent Latch-off Mode (E) Meets Class B conducted limits per CISPR 11/22 and CFR 15 subpt B Gold Plated Signal Connector (G) Overcurrent Foldback Mode (F) Sealed Pots (C) Standby Power (5VDC 1A) (P)** Physical Specifications **Voltage available as long as AC input is present Dimensions: (HxWxL) 1.59 x 4 x 9 6DIHW &RPSOLDQFH Operating Temp: 0 to 70C rated power to 50C derate linearly to 50% at 70C. IEC / EN / UL / CSA 60950-1 CE Declaration to Low Voltage Directive 2006/95/EC and Relative Humidity: 5% to 90%, non-condensing RoHS Directive 2011/65/EU Storage: -50 to 85C/20-90% RH Altitude: 6,561 operating 40,000 storage Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice. TAMURA CORPORATION OF AMERICA 1040 South Andreasen Drive, STE. 100 Escondido, CA 92029-1951 (951) 699-1270 / Fax: (951) 676-9482 (800) 472-6624 www.tamuracorp.com 1 L N