Product Information

FQA020ADC-007-S

Product Image X-ON

Datasheet
Power Line Filters 40VDC 20A PCB Mount Flanged

Manufacturer: TDK-Lambda
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 202.4431 ea
Line Total: USD 202.4431

90 - Global Stock
Ships to you between
Tue. 20 Jun to Thu. 22 Jun
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
104 - Global Stock


Ships to you between Tue. 20 Jun to Thu. 22 Jun

MOQ : 1
Multiples : 1

Stock Image

FQA020ADC-007-S
TDK-Lambda

1 : USD 200.8365
10 : USD 189.4491
30 : USD 184.938
60 : USD 175.695

     
Manufacturer
TDK-Lambda
Product Category
Power Line Filters
RoHS - XON
Y Icon ROHS
Voltage Rating
40 V
Current Rating
20 A
Mounting Style
Chassis Mount
Termination Style
Pin Terminals
Series
Fqa
Height
12.7 mm
Length
60.6 mm
Width
55.88 mm
Brand
Tdk-Lambda
Maximum Operating Temperature
+ 115 C
Minimum Operating Temperature
- 40 C
Product Type
Power Line Filters
Factory Pack Quantity :
15
Subcategory
Power Condition
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image GENH/RM
Rack Mount Power Supplies Rack Mount Kit For GENH150
Stock : 53
Stock Image GQA2W004A280V-0P7-R
Isolated DC/DC Converters 120W 24Vin 28Vout 4.28A NLog Flange
Stock : 0
Stock Image GQA2W005A240V-0P7-R
Isolated DC/DC Converters 120W 24Vin 24Vout 5A NLog Flange
Stock : 177
Stock Image GQA2W008A150V-007-R
Isolated DC/DC Converters 120W 24Vin 15Vout 8A NLog Flange
Stock : 0
Stock Image GQA2W005A240V-007-R
Isolated DC/DC Converters 120W 24Vin 24Vout 5A NLog Flange
Stock : 0
Stock Image GQA2W004A280V-007-R
Isolated DC/DC Converters 120W 24Vin 28Vout 4.28A NLog Flange
Stock : 6
Stock Image GQA24003A480V-0P7-R
Isolated DC/DC Converters 120W 24Vin 48Vout 2.5A NLog Flange
Stock : 9
Stock Image GQA24003A480V-007-R
Isolated DC/DC Converters 120W 24Vin 48Vout 2.5A NLog Flange
Stock : 0
Stock Image GEN30-50
Rack Mount Power Supplies 1500W 0-30V 0-50A 85-265VAC 47-63Hz
Stock : 0
Stock Image FQB020ADC-007-S
Power Line Filters 40VDC 20A PCB Mount Flanged
Stock : 26
Image Description
Stock Image FQB020ADC-007-S

Power Line Filters 40VDC 20A PCB Mount Flanged
Stock : 26

Stock Image FMAC-0931-1612I

Power Line Filters FMAC Input filter 3-phase 16A
Stock : 2

Stock Image B84742A0100R190

Power Line Filters 2-LINE FILTER 100A 1000Vdc
Stock : 0

Stock Image 5500.2632.04

Power Line Filters 1 STAGE 4A FMAB SINGLE PHASE 250VAC
Stock : 0

Stock Image FMBC-0960-3610

Power Line Filters FMBC Input filter 36A
Stock : 0

Stock Image B86306A0022R000

Power Line Filters LINE REACTOR 22A, 1,13mH
Stock : 0

Stock Image B84143V0011R229

Power Line Filters SINUSOIDAL OUTPUT FILTER 11A 520V
Stock : 0

Stock Image FMBC-0927-1210

Power Line Filters FMBC Input filter 12A
Stock : 2

FQA Series Specifications Model FQA Input/Output Input Voltage Range Vdc -40 to +40 Input Current (max) A 20 DC Resistance (typical) mW Positive Leg: 7.5, Negative Leg: 5 Power Loss W 5 20 A Differential Mode Attenuation at 300 kHz dB 50 (50 W source & load impedance) Common Mode Attenuation at 30 MHz dB 50 (50 W source & load impedance) Qualification Methods - Consistent with MIL-STD-883F and MIL-STD-202G Radiated Emmisions RE101 Navy Radiated Emmisions RE102 10kHz to 18GHz Fixed Wing internal, >25m Nose to Tail Compliance Matrix Conducted Emissions CE101 Surface ships and submarines (Tested with FQX-HQA-EVK-D0 evaluation Conducted Emissions CE102 Basic Curve board: FQA filter + 2X HQA DC-DC Conducted Susceptibility CS101 Curve 2, Imax=10A Converter, 200W resistive load) Conducted Susceptibility CS114 Curve 5 Conducted Susceptibility CS115 Basic Test Signal Conducted Susceptibility CS116 10kHz to 100MHz Safety Agency Certifications - IEC/UL/CSA/EN62368-1, 60950-1, CE Mark Environmental Operating Baseplate Temperature C Standard screening (-S): -40 to 115 Enhanced screening (-M): -55 to 115 Storage Temperature C -65 to 125 Operating Humidity (non condensing) %RH MIL-STD-883 Method 1004.7 Cooling - Conduction, convection or forced air Withstand Voltage (1 minute) Vdc 2250 (Terminals to Case) Vibration - MIL-STD-202G, Method 201A, Unpowered, sweep 1: 5 to 50 Hz at 05.g, sweep 2: 50 to 500 Hz at 1.5g, three axis Shock - MIL-STD-202G, Method 213B, Table 213-1, Test Condition I, Unpowered, 50G half sine 6ms, three axis Other Weight (Typ) g 100 Size (LxWxH) mm Flanged version (-007-x): 60.6 x 55.9 x 12.7, Non-flanged version (-N07-x): 60.6 x 39.5 x 12.7 Size (LxWxH) Inches Flanged version (-007-x): 2.39 x 2.20 x 0.50, Non-flanged version (-N07-x): 2.39 x 1.56 x 0.50 MTBF - Telcordia SR-332 Hrs 15 M 50 C ambient full load Warranty yrs 3 Notes See website for detailed specifications 1. See thermal performance section 2 FQA Series

Tariff Desc

8543.70.00 - ELECTRICAL MACHINES AND APPARATUS, HAVING INDIVIDUAL FUNCTIONS, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER: Other machines and apparatus Free
91 .. Other