LS200 Series 150-200W Single Output General Purpose Power Supplies Features Very low cost Small Size Wide Range AC Input Convection or Fan Cooled Five year warranty 1.6 high (For 1U racking) Key Market Segments & Applications Speci cations Model LS200 (Enclosed style with internal fan) LS200/L (U channel style - no internal fan) AC Input Voltage (300VAC for 5s) VAC 85 - 264VAC 85 - 264VAC (3) Input Frequency Hz 47 - 63Hz DC Input Voltage VDC 120 - 373VDC* Inrush Current (230VAC, cold start) A 60 Power Factor - Meets EN61000-3-2, -3 (Typical PF 0.98/0.95)(1) Input Current (115/230VAC) A 3.5 / 1.7 (typical) Temperature Coe cient - <0.02%/C (0 - 50C) Overcurrent Protection - >105% of nominal or peak. Constant current style Overvoltage Protection (2) V 3.3V: 3.8 - 4.45V, 5V: 5.75 - 6.75V, 7.5V: 8.6 - 10.1V, 12V: 15.1 - 17.75V 15V: 17.25 - 20.25V, 24V: 30.25 - 35.5V, 36V: 41.4 - 48.6V, 48V: 60 - 69.6V Overtemperature Protection (2) - Yes Hold Up Time (115/230V input) ms 20ms Leakage Current (230VAC 60Hz) mA <1mA Remote Sense - Yes Remote On/O - On: 0 - 0.8V O : 3 - 12V LED Indicator - Green LED = On Operating Temperature C Fan or forced air rating: -25 to +70C. Derate linearly to 60% load from +50 to +70C Storage Temperature C -40 to +85C Operating Humidity - 20 - 90% RH (non condensing) Storage Humidity - 10 - 95% RH (non condensing) Cooling - Internal Fan (air exhausts from fan end) Convection or customer supplied air ow Withstand Voltage - Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz: 19.6m/s constant sweep 1 min X, Y, Z for 1 hour 2 Shock - < 196.1 m/s (20G) Immunity - IEC61000-4-2, -3, -4, -5, -6, -8, -11 Safety Agency Certi cations - IEC/EN/UL/CSA60950-1, IEC/EN/UL/CSA62368-1 and CE Mark Conducted & Radiated EMI - EN55011/EN55022-B, FCC--B Weight (Typ) g 700 600 Size (LxWxH) in 7.8 x 3.9 x 1.61 Warranty yrs Five Years Notes: *Safety certi ed for AC input only (1) 115 / 230VAC input (2) Recycle AC to reset (3) (Derate linearly to 65% load from 115VAC to 85VAC)LS200 Series Output Ratings Adjust Range Max Current Max Current Peak Load Reg Line Reg Ripple Noise E ciency (4) (5) (1) Model Voltage (V) Forced Air(A) Convect.(A) Current (A) (mV) (mV) (mV) (typ) % LS200-3.3 3.3V 3.0 - 3.6 40.0 N/A - 40 16 80 67 / 68 LS200-5 5V 4.75 - 5.5 40.0 N/A - 40 20 80 72 / 75 LS200-7.5 7.5V 6.8 - 8.2 26.7 N/A - 40 20 80 74 / 77 LS200-12 12V 10.8 - 14.4 16.7 N/A - 96 48 120 76 / 79 LS200-15 15V 13.5 - 16.5 13.4 N/A - 120 60 120 80 / 83 LS200-24 24V 22 - 28.8 8.4 N/A 10.4 192 96 120 82 / 84 LS200-36 36V 32 - 40 5.6 N/A 6.9 288 144 150 82 / 85 LS200-48 48V 42 - 57.6 4.2 N/A - 384 192 200 82 / 85 LS200-3.3/L 3.3V 3.0 - 3.6 40.0 26 - 40 16 80 67 / 68 LS200-5/L 5V 4.75 - 5.5 40.0 26 - 40 20 80 72 / 75 LS200-7.5/L 7.5V 6.8 - 8.2 26.7 17.3 - 40 20 80 74 / 77 LS200-12/L 12V 10.8 - 14.4 16.7 11.6 - 96 48 120 76 / 79 LS200-15/L 15V 13.5 - 16.5 13.4 9.3 - 120 60 120 80 / 83 LS200-24/L 24V 22 - 28.8 8.4 5.8 10.4 192 96 120 82 / 84 LS200-36/L 36V 32 - 40 5.6 3.9 6.9 288 144 150 82 / 85 LS200-48/L 48V 42 - 57.6 4.2 2.9 - 384 192 200 82 / 85 Notes (4) With internal fan version LS200-xx or LS200-xx/L version with external air ow. (5) See Installation manual for derating curve. Outline Drawing Other Related Products Options Su x Description LS25 - 150 25W to 150W low cost HWS15 - 1800 15W to 1800W limited lifetime warranty /L No cover or fan (U channel) SWS300 - 1000 300 to 1000W single output Blank Cover and fan For Additional Information, please visit