Ships to you between Fri. 14 Jun to Tue. 18 Jun
ZWS-BAF Series Model Selector Output Output Adjust Max. Max. Output Ef ciency Max. Ripple Load Line OCP OVP Model Voltage Range Current Power at 200VAC and Noise Reg. Reg. (A) (V) (V) (V) (A) (W) (%) (mv pk-pk) (mV) (mV) ZWS50BAF-3 3.3 2.97-3.63 10 33.0 78 160 40 20 >10.5 3.79-4.95 ZWS50BAF-5 5 4.5-5.5 10 50.0 84 160 40 20 >10.5 5.75-7.0 ZWS50BAF-12 12 10.8-13.2 4.3 51.6 85 180 96 48 >4.51 13.8-16.2 ZWS50BAF-15 15 13.5-16.5 3.5 52.5 86 180 120 60 >3.67 17.3-20.3 ZWS50BAF-24 24 21.6-26.4 2.1 50.4 87 180 150 96 >2.2 27.6-32.4 ZWS50BAF-48 48 39.5-52.8 1.1 52.8 86 240 240 192 >1.15 55.2-64.8 ZWS75BAF-3 3.3 2.97-3.63 15 49.5 78 160 40 20 >15.7 3.79-4.95 ZWS75BAF-5 5 4.5-5.5 15 75.0 84 160 40 20 >15.7 5.75-7.0 ZWS75BAF-12 12 10.8-13.2 6.3 75.6 85 180 96 48 >6.61 13.8-16.2 ZWS75BAF-15 15 13.5-16.5 5 75.0 86 180 120 60 >5.25 17.3-20.3 ZWS75BAF-24 24 21.6-26.4 3.2 76.8 87 180 150 96 >3.36 27.6-32.4 ZWS75BAF-48 48 39.5-52.8 1.6 76.8 88 240 240 192 >1.68 55.2-64.8 ZWS100BAF-3 3.3 2.97-3.63 20 66.0 84 160 40 20 >21.0 3.79-4.95 ZWS100BAF-5 5 4.5-5.5 20 100.0 86 160 40 20 >21.0 5.75-7.0 ZWS100BAF-12 12 10.8-13.2 8.5 102.0 88 180 96 48 >8.93 13.8-16.2 ZWS100BAF-15 15 13.5-16.5 6.7 100.5 88 180 120 60 >7.04 17.3-20.3 ZWS100BAF-24 24 21.6-26.4 4.3 103.2 89 180 150 96 >4.52 27.6-32.4 ZWS100BAF-48 48 39.5-52.8 2.1 100.8 90 240 240 192 >2.21 55.2-64.8 ZWS150BAF-3 3.3 2.97-3.63 30 99 84 160 40 20 >31.5 3.79-4.95 ZWS150BAF-5 5 4.5-5.5 30 150 87 60 40 20 >31.5 5.75-7 ZWS150BAF-12 12 10.8-13.2 12.5 150 88 180 96 48 >13.13 13.8-16.2 ZWS150BAF-15 15 13.5-16.5 10 150 89 180 120 60 >10.5 17.3-20.3 ZWS150BAF-24 24 21.6-26.4 6.3 151.2 90 180 150 96 >6.62 27.6-32.4 ZWS150BAF-48 48 39.5-52.8 3.2 153.6 91 240 240 192 >3.36 55.2-64.8 (1) (1) ZWS300BAF-12 12 9.6-13.2 25.0 300 89 180 100 48 >26.25 13.8-16.2 (1) (1) ZWS300BAF-15 15 13.5-16.5 20.0 300 89 180 120 60 >23.1 17.3-20.3 (1) (1) ZWS300BAF-24 24 21.6-27.5 12.5 300 91 180 150 96 >14.7 28.8-33.6 (1) (1) ZWS300BAF-36 36 32.4-39.6 8.4 302.4 91 300 240 144 >9.87 41.4-48.6 (1) (1) ZWS300BAF-48 48 39.5-52.8 6.3 302.4 91 300 240 192 >7.35 55.2-64.8 Notes: (1) Values given for Convection Cooling: refer to detailed Speci cations & Application Notes for 0.7m/s & 1.4m/s Forced Air Option Description /A Option /L Option Suf x L-Plate and Cover /A L-Plate /L Conformally coated PCB /CO2 Remote on/off /R Terminal Block /T Terminal Block with L-Plate & Cover /TA ZWS-BAF Option Matrix /A /L /CO2 /R /T /TA Power 50W 75W 100W 150W 300W 2 ZWS-BAF Series