Surge arrester
2-electrode arrester
Series/Type: EC230XN
Ordering code: B88069X0830C103
Version/Date: Issue 06 / 2015-01-13
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color towhit. This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1 Surge arrester
(header 1 + top left bar):
Identification/Classification 2 2-electrode arrester
(header 2 + bottom left header bar):
Ordering code: (top right header bar) B88069X0830C103
Series/Type: (bottom right header bar) EC230XN
Preliminary data (optional):
(if necessary)
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohiPPD AB PD / PPD AB PM bited.
EPCOS AG is a TDK Group Company.
Surge arrester B88069X0830C103
2-electrode arrester EC230XN
Features Applications
Standard size Branch exchange
Very fast response time Line protection
High current rating Subscriber protection
Stable performance over life Alarm system
Very low capacitance Tuner
High insulation resistance Antenna protection
RoHS-compatible
Electrical specifications
1) 2)
DC spark-over voltage 230 V
Tolerance 15 %
Min. 196 V
Max. 264 V
Impulse spark-over voltage
at 100 V/s - for 99% of measured values < 550 V
- typical values of distribution < 500 V
at 1 kV/s - for 99% of measured values < 700 V
- typical values of distribution < 650 V
Service life
10 operations 50 Hz, 1 s 5 A
1 operation 50 Hz, 0.18 s (9 cycles) 20 A
10 operations 8/20 s 5 kA
1 operation 8/20 s 10 kA
1 operation 10/350 s 2.5 kA
Insulation resistance at 100 V > 10 G
DC
Capacitance at 1 MHz < 1.5 pF
Arc voltage at 1 A ~ 12 V
Glow to arc transition current < 0.5 A
Glow voltage ~ 60 V
Weight ~ 1.5 g
Operation and storage temperature C
40 ... +90
Climatic category (IEC 60068-1) 40/ 90/ 21
EC 230 YY O
Marking, red positive
EC - Series
230 - Nominal voltage
YY - Year of production
O - Non radioactive
Certification UL 497B (E163070)
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
PPD AB PD / PPD AB PM Issue 06 / 2015-01-13
Please read Cautions and warnings and Page 2 of 5
Important notes at the end of this document.