Surge arrester
2-electrode arrester
Series/Type: EM3600X
Ordering code: B88069X2311****
Date: 2016-05-19
Version: 03
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color towhit. This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1 Surge arrester
(header 1 + top left bar):
Identification/Classification 2 2-electrode arrester
(header 2 + bottom left header bar):
Ordering code: (top right header bar) B88069X2311****
Series/Type: (bottom right header bar)
EM3600X
Preliminary data (optional):
Department: PPD AB PD / PPD AB PM
Date: 2016-05-19
Version: 03
EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester B88069X2311****
2-electrode arrester EM3600X
Features Applications
Very small size AC power line devices
Fast response time Consumer electronics
Stable performance over service life Power supply
Extremely low capacitance
High insulation resistance
RoHS-compatible
Electrical specifications
1) 2)
DC spark-over voltage 3600 V
Tolerance 20 %
Min. 2880 V
Max. 4320 V
Impulse spark-over voltage
at 100 V/s - for 99 % of measured values < 5500 V
- typical values of distribution < 4000 V
at 1 kV/s - for 99 % of measured values < 6000 V
- typical values of distribution < 5500 V
Service life
10 operations 50 Hz; 1 s 1 A
300 operations 8/20 s 100 A
10 operations 8/20 s 2 kA
1 operation 8/20 s 5 kA
Insulation resistance at 100 V > 1
G
DC
Capacitance at 1 MHz < 1 pF
Arc voltage at 1 A ~ 35 V
Glow to arc transition current < 0.3 A
Glow voltage at 0.1 A ~ 170 V
AC withstand voltage
1 min 1500 V
1 s 1800 V
Weight ~ 1 g
Operation temperature C
40 ... +125
Recommended storage
- temperature +5 ... +35 C
- humidity 45 ... 80 %
- period years
2
Climatic category (IEC 60068-1) 40/125/21
Marking, red positive EM 3600 YY O
EM - Series
3600 - Nominal voltage
YY - Year of production
O - Non radioactive
Continued on next page
PPD AB PD / PPD AB PM 2016-05-19
Please read Cautions and warnings and Page 2 of 5
Important notes at the end of this document.