General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR2M n 2 pole relay with force guided contacts according to EN61810-3 (formerly EN50205) n Reinforced insulation between poles n Version P1 for use in sockets F0188-D Typical applications Emergency shut-off, press control, machine control, elevator and escalator control, safety relays Z Approvals Coil Data VDE 116064, UL E214025, TUV 968/EZ 111, CCC 2014010305743065 Coil voltage range 5 to 110VDC Technical data of approved types on request Coil versions, DC-coil Contact Data Coil Rated Operate Release Coil Rated coil Contact arrangement 1 form A + 1 form B contacts code voltage voltage voltage resistance power (1 NO + 1 NC) or VDC VDC VDC 10% mW 2 form C contacts (2 CO) 005 5 3.8 0.5 35.7 700 According EN50205 only 1NO / 1NC (11-14 and 22-21 or 12-11 and 006 6 4.5 0.6 51 706 21-24) shall be used as force guided contacts. 009 9 6.8 0.9 116 698 Rated voltage 250VAC 012 12 9 1.2 206 699 Max. switching voltage 400VAC 015 15 11.3 1.5 321 701 Rated current 6A 018 18 13.5 1.8 483 671 Contact material AgNi 021 21 16 2.1 630 700 Contact style single contact, force guided 024 24 18 2.4 823 700 1 form A + B, 1 NO + 1NC type A according to EN61810-3 036 36 27 3.6 1851 700 2 form C, 2CO type B according to EN61810-3 040 40 30 4.0 2286 700 1) Min. recommended contact load 5V/10mA 048 48 36 4.8 3291 700 1) Initial contact resistance 100m at 1A, 24VDC 060 60 45 6 5142 700 1) 20 at 10mA, 5VDC 080 80 60 8 9143 700 -1 1) Frequency of operation, with/without load 6/300min 110 110 83 11 17285 700 1) Contact ratings Coil resistance 12%. All figures are given for coil without pre-energization, at ambient temperature +23C. IEC61810-1 3 on 1 form A (NO) contact 6A, 250VAC, cos =1,70C 100x10 IEC60947-5-1 on 1 form A (NO) contact AC15 - 250V/3A DC13 - 24V/3A on the basis of DC13 - 24V/6A under conditions specified in product spec. 2158001 UL508 3 on 1 form A (NO) contact 6A, 250VAC, cos =1,70C 100x10 R300 and B300 form A (NO) + form B (NC) 1A/24VDC gen. purpose, 70C 3 100x10 6 Mechanical endurance 10x10 operations 1 07-2018, Rev. 0718 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2015 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR2M (Continued) Insulation PCB layout / terminal assignment Initial dielectric strength Bottom view on solder pins between open contacts 1500V rms between contact and coil 4000V rms between adjacent contacts 3000V 2 form C, 2 CO contacts rms Clearance/creepage between open contacts microdisconnection between contact and coil 8/8mm between adjacent contacts 5.5/5.5mm Insulation to EN 50178, type of insulation between contact and coil reinforced between adjacent contacts reinforced Other Data SR2M SR2M Plug-in S0163-CO Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -40 to 70C Category of environmental Protection IEC 61 810 RTIII RTII Weight 20g Resistance to soldering heat THT IEC 60068-2-20 260C/5s - S0163-BJ Packaging/unit tube/20 pcs. For more detailed information see product specification 2158001 1 form A + 1 form B contacts, 1 NO + 1 NC Accessories For details see datasheet Accessories Force Guided Relay SR2M plugin NOTE: indicated contact ratings and electrical endurance data for direct wiring of relays (according IEC 61810-1) for relays mounted on sockets deratings may apply. S0163 CU Dimensions SR2M S0163-CV S0273-BB SR2M Plug-In 3.9mm 2 07-2018, Rev. 0718 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2015 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company