General Purpose Relays
Industrial Relays
Potter & Brumfield
KUP Series Panel Plug-in Relay
n
AC coils: 5-240VAC, 50/60 Hz.; DC coils 6-110VDC
n
Contact arrangements of 1 form X, 1-3 form A and 1-4 form C
n
Wide selection of termination and mounting styles
n
PC terminals available
n
Push-to-test button and indicator lamp options
n
Sockets available for panel, DIN rail or PCB mounting
n
Class B coil insulation
Typical applications
Vending, commercial sewing, tool/die equipment, robotics, timers, welding,
HVAC, medical, power generators
Approvals AgCdO, 4 pole (continued)
UL E22575; CSA LR15734 1/3HP, 120VAC
Technical data of approved types on request 1/2HP, 250VAC
Total load not to exceed 30 A, 28 VDC, 120 VAC and 20 A, 250 VAC
Contact Data AgSnOInO
3
Contact arrangement 1 Form X (NO-DM); 1-3 Form A (NO); 1-4 Form C (CO) 10A, 277VAC, pf = 0.8 100x10
6
Rated voltage 240VAC Mechanical endurance 10x10 ops.
Rated current 10A
Contact material Ag AgCdO AgSnOInO
Min. recommended contact load 100mA, 12VDC 300mA, 12VDC 300mA, 12VDC Coil Data
Frequency of operation 360 ops./hr 360 ops./hr 360 ops./hr Coil voltage range 5 to 110VDC
Operate/releases time max. 15/10ms 6 to 240VAC
Bounce time max. 17ms Coil insulation system according UL Class B
Coil versions, DC coil
Contact ratings Coil Rated Operate Coil Rated coil
Type Load Cycles code voltage voltage resistance power
UL 508 VDC VDC 10% W
Ag, 1, 2 and 3 pole 1, 2 and 3 pole
5A, 240VAC 5 5 3.75 21 1.2
5A, 28VDC 6 6 4.5 32.1 1.125
1/6HP, 120VAC 12 12 9.0 120 1.2
2.5A, 120VAC, tungsten 24 24 18.0 472 1.25
1/3HP, 240VAC 48 48 36.0 1800 1.3
0.5A, 120VDC 110 110 82.5 10000 1.25
5FLA, 15LRA, 250VAC 4 pole
Ag, 4 pole 5 5 3.75 14 1.8
5A, 240VAC 6 6 4.5 20 1.8
2.5A, 120VAC, tungsten 12 12 9.0 80 1.8
0.5A, 120VDC 24 24 18.0 320 1.8
1/6HP, 120VAC 48 48 36.0 1250 1.85
1/3HP, 240VAC 110 110 82.5 6720 1.8
All figures are given for coil without preenergization, at ambient temperature +23C.
AgCdO, 1, 2 and 3 pole
10A, 240VAC
10A, 32VDC Coil versions, AC coil
5FLA, 15LRA, 250VAC Coil Rated Operate Coil Rated coil
1/3HP, 120VAC code voltage voltage resistance power
5A, 120VAC, tungsten VAC VAC 15% VA
1/2HP, 250VAC 1 and 2 pole
0.5A, 125VDC 6 6 5.1 6 2.0
10FLA, 40LRA, 125VAC 12 12 10.2 24 2.0
3A, 600VAC 24 24 20.4 85 2.0
1/2HP, 480VAC 120 120 102.0 2250 2.1
1/2HP, 600VAC 240 240 204.0 9110 2.1
1HP, 480 VAC, 3 phase 3 and 4 pole
AgCdO, 4 pole 6 6 5.1 4.2 2.8
10A, 240VAC 12 12 10.2 18 2.8
5A, 120VAC, tungsten 24 24 20.4 72 2.8
0.5A, 120VDC 120 120 102.0 1700 2.9
10A, 28VDC, resistive 240 240 204.0 7200 2.9
10FLA, 30LRA, 125VAC
3
All figures are given for coil without preenergization, at ambient temperature +23C.
5FLA, 15LRA, 250 VAC 30x10
125VA, 250 VAC
1
08-2011, Rev. 0811 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change.
a TE Connectivity Ltd. company 2.0 VA 60 Hz. COIL
2.7 VA 60 Hz. COIL
1.8 Watt DC Coil
1.2 Watt DC Coil
General Purpose Relays
Industrial Relays
Potter & Brumfield
KUP Series Panel Plug-in Relay (Continued)
Insulation Data Other Data (continued)
Initial dielectric strength
between open contacts 1200V Category of environmental protection
rms
between contact and coil 2200V IEC 61810 RT0 - open relay; RTI - dust protected
rms
between adjacent contacts 2200V Terminal type Quick connects (QC), .187, .205 or .250;
rms
Initial insulation resistance PCB-THT
between insulated elements 100M, 500VDC Terminal retention, push force
QC .205 17 lbs for 3s
QC .187, QC .250, PCB 25 lbs for 3s
Other Data Weight 85g
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content Packaging/unit tray/25 pcs., box/150pcs.
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature Accessories
DC coil Enclosed relays, 4 pole: -45C to 50C For details see datasheet Sockets and Accessories, KUP Relays
Enclosed relays, 1-3 pole: -45C to 70C
Open relays: 15C higher maximum Product Code Description
AC coil Enclosed relays, 3 and 4 pole: -45C to +45C 27E893 DIN socket (use 20C318 clip)
Enclosed relays, 1 and 2 pole: -45C to +55C 27E121 Track mount socket (use 20C314 clips)
Open relays: 15C higher maximum 27E043 Chassis mount/solder eyelet socket (use 20C254 clip)
Maximum allowable ambient temperature vs voltage (KUP enlcosed) 27E046 Chassis mount/PCB socket (use 20C254 clip)
27E067 Chassis mount/quick connect socket (use 20C254 clip)
75
75
27E396 Snap-in/quick connect socket (use 20C254 clip)
70
70
60
60
50
50
40
40
30
30
20 20
100
110 120 130 140 150 160 100 110 120 130 140
% of Nominal Voltage DC % Of Nominal 60 Hz. Voltage
Dimensions
Seated Heights For KU (open) Relays
KU bracket type
1.391 (35.33mm) for #6-32 stud
2.43 MAX.*
1.437
with .218 (5.54mm) locating tab.
(61.72)
.19
(36.50)
2.33 MAX.**
(4.8) X
X
(59.18)
1.52 (38.6mm) for bracket
2.29 MAX.***
with 2-#6 32 tapped holes.
(58.17)
.63
.63
X
(16.0)
(16.0)
1.282 (32.56mm) for #6-32 tapped core
2.27 MAX.*
with .125 (3.18mm) or .218 (5.54mm) locating tab.
(57.7)
2.171 MAX.**
.16 (55.14)
(2) #6-32 THREAD
(4.1)
2.125 MAX.*** 2.046 (51.97mm) for relay
TAPPED HOLES (53.98)
with printed circuit terminals.
KU stud type
STUD TYPE also available with .125 (3.18mm)
1.468 MAX.
2.27 MAX.*
(37.29)
.
.031 REF. .031 REF tab, as well as without stud and locating tab.
(57.7)
(.79) (.79)
2.171 MAX.**
Models without stud have core tapped #6-32
1 2 3
(55.14)
THREAD, .25 (6.4mm) minimum depth.
4 5 6
2.125 MAX.***
1.391
(53.98) 1.282 MAX.
7 8 9
(35.33)
(35.56)
.218
*Dimensions with .250 (6.35mm) terminals.
1.687 MAX.
(5.54)
.109 MAX.
A B
(42.85) ** Dimensions with .110 (2.79mm) or .205 (5.21mm) terminals.
(2.77)
*** Dimensions with .187 (4.75mm) terminals.
1.39 MAX.*
.31
.065
(35.3)
(7.9)
(1.65)
.437 1.29 MAX.**
.150
(32.8)
#6-32
(11.10) TAB WIDTH
1.25 MAX.*** THREAD
(3.81)
(31.8)
Relay front diagrams
Models with 6.35mm 1-3 pole models with 4 pole models
(.250) QC terminals all other terminals
1.531 MAX. 1.531 MAX.
1.531 MAX.
(38.89) (38.89) (38.89)
1 2 3
1 2 3 1 1 2 2 3 3 4
4 5 6 4
4 5 6 5 6 7 8
1.406 MAX.
1.406 MAX. 1.406 MAX.
7 9
7 8 9 9 10 11 12
(35.71)
(35.71) (35.71)
A B
A B A B
2
08-2011, Rev. 0811 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
2011 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change.
a TE Connectivity Ltd. company