Catalog 1308242
Issued 3-03 P&B
CG series
CMOS IC Time Delay Relay
Repeatability to .05%
Choice of timing modes
Delay on operate
Delay on release
Interval on
Knob adjustable
10A output relay with DPDT contacts
Various models time from 0.5 sec. to 100 min.
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Timing Modes Contact Data @ 25C
Arrangements: 2 Form C (DPDT).
Delay on operate Delay period begins when input voltage is applied. At
Material: Silver-cadmium oxide alloy.
the end of the delay period, the relay will operate and will not release until
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC;
input voltage is removed. Reset occurs when input voltage is reapplied.
1/3 HP @ 120VAC.
Expected Mechanical Life: 10 million operations.
INPUT ON
Expected Electrical Life: 100,000 operations, min., at rated load.
VOLTAGE OFF
N.O. RELAY ON
TIME
CONTACTS OFF
Initial Dielectric Strength
Between Open Contacts: 500V rms, 60 Hz.
Delay on release Input voltage must be applied continuously to operate
Between All Other Conductors: 500V rms, 60 Hz.
the internal relay. When the control switch is closed, the relay energizes.
When the control switch is opened, timing begins. When timing is
complete, the relay will de-energize. Time may be reset to zero during
timing by closing the control switch.
CONTROL ON
SWITCH OFF Input Data @ 25C
N.O. RELAY ON
Voltage: 120VAC and 24VDC.
TIME
CONTACTS OFF
Power Requirement: AC Types: Typically less than 3 VA.
DC Types: Typically less than 3 W.
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Interval on The relay energizes and timing begins when input voltage is
Input Voltages & Limits @25C
applied. At the end of the time delay period the relay will de-energize.
Voltage Nominal Minimum Maximum
Reset is accomplished by removing, then reapplying, the input voltage.
Type Voltage Voltage Voltage
AC 120 105 130
DC 24 20 32
INPUT ON
VOLTAGE OFF
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.
N.O. RELAY ON
TIME
CONTACTS OFF
Environmental Data
Temperature Range: Storage: -40C to +85C.
Timing Specifications
Operating: -10C to +55C.
Timing Ranges: From 0.5 to 5.0 sec. through 10 to 100 min.
Timing Adjustment: Knob adjustable.
Tolerance (for AC units add 1/2 cycle 60 Hz.):
Knob Adj. Types:0, +10% of max. specified at high end of timing range;
Mechanical Data
+0, 10% of min. specified at low end.
Termination: 8- or 11-pin octal style plug.
Delta Time (for AC units add 1 cycle 60 Hz.): 2%, typ.; 5%, max.
Repeatability (including first cycle of operation): Enclosure: Yellow plastic case. Knob adjustable types have dial scale for
reference only.
AC: 0.1%, typ.; 0.5%, max.; but not less than 16 ms.
DC: 0.05% typ.; 0.1% max.; but not less than 3 ms. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on)
screw terminal sockets. 11-pin types fit either 27E123 or
Release Time: 30 ms, typ.; 45 ms, max.
Recycle Time: AC: 40 ms, typ.; 60 ms, max. 27E892 (snap-on) screw terminal sockets.
Weight: 8 oz. (227g) approximately.
DC: 30 ms, typ.; 45 ms, max.
Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com
reference purposes only. (millimeters) unless otherwise subject to change. Technical support:
1220
specified. Refer to inside back cover.Catalog 1308242
Issued 3-03 P&B
Ordering Information Authorized distributors are more likely to stock boldface items listed below.
Delay on Operate Models
Delay on Release Models
Voltage Time Adjustment Wiring Dia. Part Number
Voltage Time Adjustment Wiring Dia. Part Number
0.5 to 5 Min. CGB-38-70005M
120VAC 1 to 10 Min. Knob 2 CGB-38-78010M
120VAC 1 to 10 Min. Knob 1 CGB-38-70010M
5 to 50 Min. CGB-38-78050M
5 to 50 Min. CGB-38-70050M
10 to 100 Min. CGB-38-70100M
Interval on Models
24VDC 5 to 50 Min. Knob 1 CGD-38-30050M
Voltage Time Adjustment Wiring Dia. Part Number
120VAC 0.5 to 5 Sec. Knob 1 CGB-38-79005S
1 to 10 Min. CGB-38-79010M
24VDC 1 to 10 Min. Knob 1 CGD-38-39010M
Outline Dimensions
2.406 MAX.
(61.1)
2.937 MAX. .56 1.781 MAX.
.60
(45.2)
(74.6) (14.2)
(15.2)
Wiring Diagrams Bottom Views (pins numbered clockwise from keyway)
EXT.
CONT.
_
_
+
+
INPUT INPUT
SW*
(DC POLARITY INDICATED) (DC POLARITY INDICATED)
Fig.2
Fig.1
11 Pin
8 Pin
* If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: a dry circuit switch is recommemded. A
dry circuit switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly.
** Note: input polarity for DC operation. For most reliable operation on AC, connect high side to + and low side to .
Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com
reference purposes only. (millimeters) unless otherwise subject to change. Technical support:
1221