Product Information

G2UM300VL20 24-240VAC/DC

G2UM300VL20 24-240VAC/DC electronic component of Tele

Datasheet
RELAY, VOLTAGE SENSING, DPDT, 240V

Manufacturer: Tele
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 339.4924 ea
Line Total: USD 339.49

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 03 May to Thu. 09 May

MOQ : 1
Multiples : 1
1 : USD 272.4173

     
Manufacturer
Product Category
Product Range
Contact Configuration
Contact Current
Relay Mounting
Contact Voltage Vac
Relay Terminals
Contact Voltage Vdc
Supply Voltage Max
Power Consumption
Approvals Standards
Svhc
Adjustment Type
Contact Current Ac Max
Contact Voltage Ac Max
Control Voltage Type
Delay Time Range
External Depth
External Length / Height
External Width
Nom Input Voltage
Timer Functions
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
V2ZI10 12-240V AC/DC electronic component of Tele V2ZI10 12-240V AC/DC

TIME RELAY, ASYMMETRIC FLASHER, 12-240V
Stock : 0

G2ZI20 electronic component of Tele G2ZI20

TIMER, TWO-TIME, MULTIFUNCTION-6
Stock : 0

G2ZIF20 24-240V electronic component of Tele G2ZIF20 24-240V

TIMER, MULTIFUNCTION-7, 2 CO
Stock : 0

OVL1 24VAC/DC electronic component of Tele OVL1 24VAC/DC

RELAY, SPDT, 28VAC, 8A
Stock : 0

R20 electronic component of Tele R20

POTENTIOMETER, REMOTE, 1-10 SCALE
Stock : 0

V2ZM10 12-240V AC/DC electronic component of Tele V2ZM10 12-240V AC/DC

TIME RELAY, MULTIFUNCTION, 12-240V AC/DC
Stock : 0

E1YU400V01 electronic component of Tele E1YU400V01

RELAY, VOLTAGE SENSING, SPDT, 400VAC
Stock : 0

TVC11 electronic component of Tele TVC11

BASE FOR SERIES FRONT; Socket Mounting:-; Socket Terminals:-; No. of Pins:-; Current Rating:-; Voltage Rating:-; Product Range:-; SVHC:No SVHC (27-Jun-2018); Accessory Type:Mounting Base
Stock : 0

TST1 15 electronic component of Tele TST1 15

THYRISTOR CONTROL UNIT
Stock : 0

Image Description
FLP25R9.0-UBW electronic component of Bivar FLP25R9.0-UBW

LED Light Pipes Light Pipe Assembly, Flexible, 2mm Fiber Optic Core, Right Angle, 7mm Lens, 9 in., Blue
Stock : 0

BMWS 8151-0/9 electronic component of Turck BMWS 8151-0/9

EUROFAST, M12 RECEPTACLE, 5 POSITION, PG9 GLAND
Stock : 0

FLP2R11.0-UW electronic component of Bivar FLP2R11.0-UW

LED Light Pipes Light Pipe Assembly, Flexible, 2mm Fiber Optic Core, Right Angle, 5.1mm Round Lens, 11 in., White
Stock : 0

BMX055-0273141179 electronic component of Bosch BMX055-0273141179

BMX055-0273141179
Stock : 0

FLP2R11.5-SUR electronic component of Bivar FLP2R11.5-SUR

LED Light Pipes Light Pipe Flex 5.1mm Lens Red
Stock : 0

BMXAMM0600 electronic component of Schneider BMXAMM0600

ANA 4 IN U/I 2 OUT U/I 09P2837
Stock : 0

2487943 electronic component of Kroy 2487943

LABEL PRINTER TAPE
Stock : 0

FLP2R2.0-SUR electronic component of Bivar FLP2R2.0-SUR

LED Light Pipes Light Pipe Flex 5.1mm Lens Red
Stock : 0

BMXCPS3020 electronic component of Schneider BMXCPS3020

HIGH POWER ISOL 24TO48 VDC POWER SUPPLY 64M2357
Stock : 0

BMXCPS3500 electronic component of Schneider BMXCPS3500

HIGH POWER AC POWER SUPPLY 64M2358
Stock : 1

G2UM300VL20 AC/DC voltage monitoring in 1-phase mains 24-240V Monitoring relays - GAMMA series Multifunction 16.6 to 400Hz Fault latch Zoom voltage 24 to 240V AC/DC 2 change-over contacts Width 22.5mm Industrial design Technical data 1. Functions 6. Output circuit AC/DC voltage monitoring in 1-phase mains with adjustable 2 potential free change-over contacts thresholds, timing for start-up suppression and tripping delay Rated voltage: 250V AC separately adjustable and the following functions (selectable by means Switching capacity: 750VA (3A / 250V AC) of rotary switch) If the distance between the devices is less than 5mm OVER Overvoltage monitoring Switching capacity: 1250VA (5A / 250V AC) OVER+LATCH Overvoltage monitoring with fault latch If the distance between the devices is greater than 5mm UNDER Undervoltage monitoring Fusing: 5A fast acting 6 UNDER+LATCH Undervoltage monitoring with fault latch Mechanical life: 20 x 10 operations 5 WIN Monitoring the window between Min and Max Electrical life: 2 x 10 operations at 1000VA resistive load WIN+LATCH Monitoring the window between Switching frequency: max. 60/min at 100VA resistive load Min and Max with fault latch max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1) 2. Time ranges Overvoltage category: III (in accordance with IEC 60664-1) Adjustment range Rated surge voltage: 4kV Start-up suppression time: 0s 10s Tripping delay: 0.1s 10s 7. Measuring circuit Fusing: max. 20A (in accordance with UL 508) 3. Indicators Measured variable: DC or AC Sinus (16.6 to 400Hz) Green LED ON: indication of supply voltage Input: Green LED flashes: indication of start-up suppression time 30V AC/DC terminals E-F1(+) Yellow LED ON/OFF: indication of relay output 60V AC/DC terminals E-F2(+) Red LED ON/OFF: indication of failure of the corresponding 300V AC/DC terminals E-F3(+) threshold Overload capacity: Red LED flashes: indication of tripping delay 30V AC/DC 100Veff of the corresponding threshold 60V AC/DC 150Veff 300V AC/DC 440Veff 4. Mechanical design Input resistance: Self-extinguishing plastic housing, IP rating IP40 30V AC/DC 47k Mounted on DIN-Rail TS 35 according to EN 60715 60V AC/DC 100k Mounting position: any 300V AC/DC 470k Shockproof terminal connection according to VBG 4 (PZ1 required), Switching threshold IP rating IP20 Max: 10% to 100% of U N Tightening torque: max. 1Nm Min: 5% to 95% of U N Terminal capacity: Overvoltage category: III (in accordance with IEC 60664-1) 1 x 0.5 to 2.5mm with/without multicore cable end Rated surge voltage: 4kV 1 x 4mm without multicore cable end 2 x 0.5 to 1.5mm with/without multicore cable end 8. Accuracy 2 x 2.5mm flexible without multicore cable end Base accuracy: 5% (of maximum scale value) Frequency response: -10% to +5% (at 16.6 to 400Hz) 5. Input circuit Adjustment accuracy: 5% (of maximum scale value) Supply voltage: Repetition accuracy: 2% 24 to 240V AC/DC terminals A1-A2 (galvanically separated) Voltage influence: - Tolerance: Temperature influence: 0.05% / C 24 to 240V DC -20% to +25% 24 to 240V AC -15% to +10% 9. Ambient conditions Rated frequency: Ambient temperature: -25 to +55C 24 to 240V AC 48 to 400Hz (in accordance with IEC 60068-1) 48 to 240V AC 16 to 48Hz -25 to +40C (in accordance with UL 508) Rated consumption: 4.5VA (1W) Storage temperature: -25 to +70C Duration of operation: 100% Transport temperature: -25 to +70C Reset time: 500ms Relative humidity: 15% to 85% Wave form for AC: Sinus (in accordance with IEC 60721-3-3 class 3K3) Residual ripple for DC: 10% Pollution degree: 3 (in accordance with IEC 60664-1) Drop-out voltage: >15% of the supply voltage Vibration resistance: 10 to 55Hz 0.35mm Overvoltage category: III (in accordance with IEC 60661-1) (in accordance with IEC 60068-2-6) Rated surge voltage: 4kV Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27) www.tele-online.comG2UM300VL20 24-240V Window function (WIN, WIN+LATCH) Functions The output relays switch into on-position (yellow LED illuminated) when the measured voltage exceeds the value adjusted at the MIN-regulator. When the supply voltage U is applied, the output relays switch into When the measured voltage exceeds the value adjusted at the MAX- on-position (yellow LED illuminated) and the set interval of the start-up regulator, the set interval of the tripping delay (DELAY) begins (red LED suppression (START) begins (green LED U flashes). Changes of the MAX flashes). After the interval has expired (red LED MAX illuminated), measured voltage during this period do not affect the state of the output the output relays switch into off-position (yellow LED not illuminated). relay. After the interval has expired the green LED is illuminated steadily. The output relays again switch into on-position (yellow LED illuminated) For all the functions the LEDs MIN and MAX are flashing alternating, when the measured voltage falls below the value adjusted at the MAX- when the minimum value for the measured voltage was chosen to be regulator (red LED MAX not illuminated). When the measured voltage greater than the maximum value. falls below the value adjusted at the MIN-regulator, the set interval of the tripping delay (DELAY) begins again (red LED MIN flashes). After the Overvoltage monitoring (OVER, OVER+LATCH) interval has expired (red LED MIN illuminated), the output relays switch When the measured voltage exceeds the value adjusted at the into off-position (yellow LED not illuminated). MAX-regulator, the set interval of the tripping delay (DELAY) begins (red LED MAX flashes). After the interval has expired (red LED MAX illuminated), the output relays switch into off-position (yellow LED not illuminated). The output relays again switch into on-position (yellow LED illuminated), when the measured voltage falls below the value adjusted at the MIN-regulator (red LED MAX not illuminated). If the fault latch is activated (OVER+LATCH) and the measured voltage remains above the MAX-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the measured voltage falls below the value adjusted at the MIN-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring cycle begins with the set interval of the start-up suppression (START). If the fault latch is activated (WIN+LATCH) and the measured voltage remains below the MIN-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the measured voltage exceeds the value adjusted at the MIN-regulator. If the measured voltage remains above the MAX-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the measured voltage falls below the value adjusted at the MAX-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring cycle begins with the set interval of the start-up suppression (START). Undervoltage monitoring (UNDER, UNDER+LATCH) When the measured voltage falls below the value adjusted at the MIN-regulator, the set interval of the tripping delay (DELAY) begins (red LED MIN flashes). After the interval has expired (red LED MIN illuminated), the output relays switch into off-position (yellow LED not illuminated). The output relays again switch into on-position (yellow LED illuminated), when the measured voltage exceeds the value adjusted at the MAX-regulator. If the fault latch is activated (UNDER+LATCH) and the measured voltage remains below the MIN-value longer than the set interval of the tripping delay, the output relays remain in the off- position even if the measured voltage exceeds the value adjusted at the MAX-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring cycle begins with the set interval of the start-up suppression (START). www.tele-online.com

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted