Product Information

GRF342-5

GRF342-5 electronic component of Teledyne

Datasheet
High Frequency / RF Relays 5V DC-6GHz .15W

Manufacturer: Teledyne
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Obsolete
Availability Price Quantity
0 - Global Stock

MOQ : 1
Multiples : 1

Stock Image

GRF342-5
Teledyne

1 : USD 94.5808
25 : USD 82.9332
50 : USD 79.1658
100 : USD 77.6034
250 : USD 74.9196
N/A

Obsolete
0 - Global Stock

MOQ : 1
Multiples : 1

Stock Image

GRF342-5
Teledyne

1 : USD 75.5379
5 : USD 75.3204
10 : USD 73.6116
100 : USD 70.598
250 : USD 65.8859
500 : USD 65.8031
1000 : USD 65.7823
N/A

Obsolete
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Contact Form
Contact Termination
Coil Voltage
Frequency
Power Consumption
Series
Brand
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
GRF522-12 electronic component of Teledyne GRF522-12

Electromechanical Relay 12VDC 144Ohm 1A DPDT (18x18x8.5)mm SMD High Frequency Relay
Stock : 0

HD02CFW electronic component of Teledyne HD02CFW

Solid State Relays - PCB Mount 2mA 60V SSR w/ Switch Status
Stock : 0

HD20CFY electronic component of Teledyne HD20CFY

Solid State Relays - PCB Mount Relay
Stock : 1

HD22CFW electronic component of Teledyne HD22CFW

Solid State Relays - PCB Mount Relay
Stock : 0

HDO4022 electronic component of Teledyne HDO4022

Benchtop Oscilloscopes High-Definition Oscilloscope
Stock : 0

HD20CFW electronic component of Teledyne HD20CFW

Solid State Relays - PCB Mount Relay
Stock : 32

HDO4022-W5 electronic component of Teledyne HDO4022-W5

Calibration, Warranties, & Service Plans 5 Year Warranty "including Standard"
Stock : 0

HDO4022-T5 electronic component of Teledyne HDO4022-T5

Calibration, Warranties, & Service Plans 5 Year Warranty w/ Annual Traceable Cal
Stock : 0

HDO4022-C5 electronic component of Teledyne HDO4022-C5

Calibration, Warranties, & Service Plans 5 Year Annual Traceable Cal
Stock : 0

HD22CFY electronic component of Teledyne HD22CFY

Solid State Relays - PCB Mount Relay
Stock : 0

Image Description
PRMAPD-5X electronic component of TE Connectivity PRMAPD-5X

High Frequency / RF Relays 2FormC (DPDT) 5VDC
Stock : 0

A152-20-26/G electronic component of Teledyne A152-20-26/G

High Frequency / RF Relays 20V Ultramin High Repeat
Stock : 25

A152-5-26/G electronic component of Teledyne A152-5-26/G

High Frequency / RF Relays 5V Ultramin High Repeat
Stock : 5

R596312100 electronic component of Radiall R596312100

Coaxial Switches MICRO SPDT 3GHz NO 12V
Stock : 0

R596813100 electronic component of Radiall R596813100

Coaxial Switches MICRO-SPDT 8GHz MO 24V
Stock : 0

HF303 electronic component of TE Connectivity HF303

High Frequency / RF Relays RELAY HI FREQ SPDT 5VDC SMT
Stock : 329

HF306 electronic component of TE Connectivity HF306

High Frequency / RF Relays RELAY HI FREQ SPDT 12VDC SMT
Stock : 228

HF351 electronic component of TE Connectivity HF351

TE Connectivity Axicom High Frequency RF Relays RELAY HI FREQ SPDT 3VDC SMT
Stock : 0

HF357 electronic component of TE Connectivity HF357

High Frequency / RF Relays 1 POLE NON-LATCH 24V 400
Stock : 0

HF393 electronic component of TE Connectivity HF393

High Frequency RF Relays 2A 5VDC 140MW 2COIL PCB HF RELAY
Stock : 128

SERIES SURFACE MOUNT, GRF342 MAGNETIC-LATCHING BROADBAND RF RELAYS DPDT switch matrices, automated test equipment, spacecraft and DESCRIPTION other applications that require dependable high-frequency The Series GRF342 relay is a hermetically sealed, signal fidelity and performance. Its low profile makes the ultraminiature RF relay designed from inception for surface GRF342 ideal for applications where extreme packaging mount applications. This magnetic-latching relay features density and/or close PC board spacing are required. extremely low internal circuit losses for exceptional time and frequency domain response characteristics through and Unique features and manufacturing techniques include: beyond the UHF spectrum and into the S band. The GRF342 features a unique ground shield that isolates and shields Positive mounting means to RF ground plane. each lead to ensure excellent contact-to-contact and pole-to- Unique uniframe design provides high magnetic efficiency pole isolation. This ground shield provides an RF ground and mechanical rigidity. interface that results in improved high-frequency High force/mass ratios for resistance to shock and performance as well as parametric repeatability. The vibration. GRF342 extends performance advantages over similar RF Advanced cleaning techniques provide maximum devices that simply offer formed leads for surface mounting. assurance of internal cleanliness. Gold-plated precious metal alloy contacts ensure reliable The GRF342 is robust to shock, vibration and temperature dc and RF signal switching, as well as low and stable extremes for use in space applications and other demanding insertion loss. environments. It is engineered for use in RF attenuators, RF Robust to high temperature solder reflow environments. ENVIRONMENTAL AND PHYSICAL SPECIFICATIONS PRINCIPLE OF OPERATION PERMANENT MAGNET MAGNETIC CIRCUIT A Temperature Energizing Coil B produces a 55C to +85C MAGNETIC CIRCUIT B (Ambient) SOFT IRON FRAME magnetic field opposing the magnetic field of the Vibration 10 gs to 1000 Hz (Note 1) + permanent magnet in Circuit COIL A COIL B 30 gs for 6 msec (Note 1) B. As the net holding force Shock half-sine SOFT IRON SOFT IRON decreases, the attractive force COIL A COIL B - in the air gap of Circuit A, Enclosure Hermetically sealed AIR GAP SOFT IRON ARMATURE which also results from the STATIONARY CONTACT Weight 0.1 oz. (2.9g) max. magnetic field of the permanent magnet, becomes great enough to break the MOVING armature free of Core B, and CONTACT snap it into a closed position against Core A. The armature remains in this position upon removal of power from Coil B, but will snap back into position B upon energizing Coil A. Since operation depends upon cancellation of a magnetic field, it is necessary to apply the correct polarity to the relay coils as indicated on the relay schematic. When latching relays are installed in equipment, the latch and reset coils should not be pulsed simultaneously. Coils should not be pulsed with less than rated coil voltage and the pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magnetic neutral position. GRF342 Page 1 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2003 TELEDYNE RELAYS www.teledynerelays.com GRF342/0703/Q1 - +SERIES GRF342 TYPICAL RF CHARACTERISTICS (See RF Notes) Isolation Across Contacts (RF Note 4) Isolation Pole to Pole (RF Note 5) -25 -25 -30 -30 -35 -35 -40 -45 -40 -50 -45 -55 -50 -60 -65 -55 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Frequency (MHz) Frequency (MHz) Insertion Loss (RF Note 6) VSWR (RF Note 6) -0.1 2.2 2.0 -0.3 1.8 -0.5 1.6 -0.7 1.4 -0.9 1.2 -1.1 1.0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Frequency (MHz) Frequency (MHz) GRF342 Time Response (RF Note 6) 1.1 0.9 90% 0.7 37ps reference 0.5 61ps propagation delay time 0.3 52.5ps pulse rise time 10% 0.1 -0.1 -100 0 100 200 300 400 500 600 700 800 900 Time (ps) RF NOTES 1. Test conditions: a. Fixture: .031 copper clad, reinforced PTFE, RT/duroid 6002 with SMA connectors. (RT/duroid is a registered trademark of Rogers Corporation.) b. RF ground shield is soldered to PCB RF ground plane. c. Room ambient temperature. d. Terminals not tested were terminated with 50-ohm load. e. Contact signal level: 10 dBm. f. No. of test samples: 2. 2. Data presented herein represents typical characteristics and is not intended for use as specification limits. 3. Data is per pole, except for pole-to-pole data. 4. Data is the average from readings taken on all open contacts. 5. Data is the average from readings taken on poles with coil energized and de-energized. 6. Data is the average from readings taken on all closed contacts. 7. Test fixture effect de-embedded from frequency and time response data. 2003 TELEDYNE RELAYS SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE GRF342 Page 2 www.teledynerelays.com GRF342/0703/Q1 Insertion Loss (dB) Isolation (dB) Volt Isolation (dB) VSWR

Tariff Desc

8536.41 RELAYS, coaxial Op. 22.05.1984 Dec. 22.05.1984 - TC 8438500
TELEDYNE COAX
Teledyne e2v
TELEDYNE INDUSTRIAL
Teledyne LeCroy
Teledyne LeCroy Inc
TELEDYNE MICROWAVE SOLUTIONS
TELEDYNE MIL SSR
TELEDYNE RELAYS
Teledyne Technologies

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted