AC/DC Enclosed Power Supply TXL 035 Series, 35 Watt Compact metal case with screw terminal block Dual output models with isolated outputs Universal input 85 - 264 Vac EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1 Compliance to EN 61000-3-2 Short circuit and overvoltage protection International safety approvals CB 3 year product warranty Scheme IEC 60950-1 UL 60950-1 IEC 62368-1 UL 62368-1 The TRACOPOWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC stan- dards and the Low Voltage Directive (LVD). Models Order Code Power Output voltage Output current max. Efciencfi y max. Vout 1 Vout 2 Vout 1 Vout 2 typ. TXL 035-3.3S Models 30 W 3.3 VDC 9.0 A 74 % TXL 035-05S 35 W 5 VDC 7.0 A 79 % TXL 035-12S 36 W 12 VDC 3.0 A 82 % TXL 035-15S 36 W 15 VDC 2.4 A 84 % TXL 035-24S 36 W 24 VDC 1.5 A 85 % TXL 035-48S 38 W 48 VDC 0.8 A 86 % 1) TXL 035-0512D 35 W +5 VDC +12 VDC 4.0 A 2.5 A 79 % 1) TXL 035-0524D 35 W +5 VDC +24 VDC 4.0 A 1.3 A 79 % 1) TXL 035-1212D 36 W +12 VDC 12 VDC 3.0 A 1.5 A 83 % 1) TXL 035-1515D 36 W +15 VDC 15 VDC 2.4 A 1.5 A 84 % 1) Total power should not exceed max. output power TXL 035 Series, 35 Watt Input Specifications Input voltage range nominal 100 240 VAC AC range (universal input) 88 264 VAC DC range 125 375 VDC (Designed for, no certification) Input frequency 47 63 Hz Input current at full load at 100 VAC 1.0 A max. Input inrush current at 115 VAC / 230 VAC 30 A max. / 50 A max. Zero load power consumption only single output models: 0.5 W max. (green mode function) Recommended circuit breaker (characteristic C or slow bow fuse) 5 A Output Specifications Output voltage adjustment range 10 % (only Vout 1) Regulation Input variation 1.0 % max. Load variation (20 - 100%) main output: 2.0 % max. Vout 2: 5.0 % max. Minimum load single output models: not required dual output models: Vout 1 requires 0.3 A Temperature coefficient 0.02 %/K Start-up time 1 s max. Rise time single output models: 20 ms max. dual output models: 30 ms max. Hold-up time single output models: 40 ms min. dual output models: 60 ms min. Ripple and noise measured with external capacitors: 0.1 F and 47 F parallel capacitor (20Mhz Bandwidth) Vout 1 3.3 & 5 Vout models: 70 mVp-p typ. 12 Vout model: 120 mVp-p typ. 15 & 24 Vout models: 150 mVp-p typ. 48 Vout model: 200 mVp-p typ. Vout 2 (-)12 VDC models: 120 mVp-p typ. 15 VDC models: 150 mVp-p typ. Overload protection by current limitation 105 150 % of Iout max. Short circuit protection hiccup mode (automatic recovery) Overvoltage protection (Latch off, recovery after restart) 115 140 % of nominal Vout (only Vout 1) Capacitive load www.tracopower.com/products/txl-capload.pdf General Specifications Temperature ranges Operating 20C to +70C (with derating) Storage 40C to +85C Output power derating Temperature 2.5 %/K above +50C Low input voltage 0.8 %/V below 100 VAC Cooling natural convection (20 lfm), no internal fan Humidity (non condensing) 20 90 % rel. H max. Altitude during operation 2000 m Isolation voltage (60 sec.) Input / Output 3000 VAC Input / PE 1500 VAC Output / PE 500 VAC Isolation resistance (at 500 VDC) 100 MOhm min. Leakage current (at 264 VAC/60Hz) 1 mA max. All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated.