AC/DC Enclosed Power Supply TXL 230 Series, 230 Watt Compact metal case with screw terminal block Universal input 85 - 264 Vac EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1 Compliance to EN 61000-3-2 Active power factor correction Short circuit and overvoltage protection International safety approvals 3 year product warranty CB Scheme UL 60950-1 The TRACOPOWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC stan- dards and the Low Voltage Directive (LVD). Models Order Code Power max. Output voltage nom. Output current max. Efciencfi y typ. TXL 230-12S 230 W 12 VDC 19.2 A 83 % Models TXL 230-24S 230 W 24 VDC 9.6 A 85 % TXL 230-48S 230 W 48 VDC 4.8 A 86 % TXL 230 Series, 230 Watt Input Specifications Input voltage range nominal 100 240 VAC AC range (universal input) 85 264 VAC DC range 120 375 VDC Input frequency 47 63 Hz Input current at full load at 100 VAC 3.2 A max. Input inrush current at 115 VAC / 230 VAC 35 A max. / 70 A max. Power Factor Correction (PFC) PF > 0.95 Recommended circuit breaker (characteristic C or slow bow fuse) 10 A Output Specifications Output voltage adjustment range 10 % Regulation Input variation 1.0 % max. Load variation (20 - 100%) 1.0 % max. Minimum load not required Temperature coefficient 0.02 %/K Start-up time 3 s max. Rise time 20 ms max. Hold-up time at 230 VAC 20 ms min. Ripple and noise (20Mhz Bandwidth) 12 Vout model: 120 mVp-p typ. 24 & 48 Vout models: 200 mVp-p typ. measured with external capacitors: 0.1 F and 47 F parallel capacitor Overload protection by current limitation 105 150 % of Iout max. Short circuit protection hiccup mode (automatic recovery) Overvoltage protection (Latch off, recovery after restart) 115 140 % of nominal Vout Capacitive load www.tracopower.com/products/txl-capload.pdf General Specifications Temperature ranges Operating 20C to +70C (with derating) Storage 40C to +85C Output power derating Temperature 2.5 %/K above +50C Low input voltage 0.7 %/V below 100 VAC Cooling forced airflow cooling with DC fan Over Temperature Protection over 90C thermal shutdown, auto. recovery Humidity (non condensing) 20 90 % rel. H max. Altitude during operation 2000 m Isolation voltage (60 sec.) Input / Output 3000 VAC Input / PE 1500 VAC Output / PE 500 VAC Isolation resistance (at 500 VDC) 100 MOhm min. Leakage current (at 264 VAC/60Hz) 1.5 mA max. Remote Sense open or connected to the load (RS+, RS) Remote on/off Power On: 0 0.7 VDC Power Off: 3 10 VDC Off idle current 3 10 mA All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated.