2 Z H R U 35 F H Q Q F R + W3 Z H R U F H Q Q F R W3 2 35 + A CB % Scheme F H L Q FK D O G W D D 7 *H H Q U O W D F H L Q FK D O G W D D Current limiting > 100 % Irated L (+) Ambient temp. operating / storage temperature -25+70 C -25 C+85 C AC Max. perm. air humidity (operation) 95 % RH N () Degree of protection / Class of protection IP 20 / I, with PE connection 13 Data 14 PE Link DC Pollution degree 2 DC OK Insulation voltage input/output 4 kV I/O 2 kV I/earth 0.5 kV O/earth MTBF according to IEC 61709 CP T 70/90 W > 1.8 Mio. h CP T 140 W > 1.2 Mio. h CP T 180/360/600 W > 0.9 Mio. h Protection against reverse voltages from the load 16 V DC / 35 V DC / 63 V DC Parallel connection option yes, without diode module Housing version metal, corrosion resistant Overload protection Thermal protection, autom. restart Short circuit protection Unlimited, autom. restart Indication Dual LED Operational: Green LED Error: Red LED Mounting position, installation notice Horizontal on TS 35 mounting rail, with 80 mm space at top and bottom. Side by side mounting with 50 mm clearance. Stripping length (rated connection) 7 mm 6 L F G Q L O J L D Q D W Q R L Power Good Signal Trigger point 12 V Version 911 V DC 24 V Version 18...22 V DC 48 V Version 36...44 V DC W F D WL J D R HH Q V O L D W JQ Q R F WL O HQ D I U W R 3 NO contact 30 V DC / 1.0 A max. for 12/24 V DC modules 48 V DC/ 0.5 A max. for 36/48 V DC modules Active output signal 70 W 11 V DC 1 V DC / 20 mA max. 140 W 11 V DC 1 V DC / 40 mA max. 0 D W L P L O J Q L Y D H U J D H Q R V W D W H FX U U H W Q > 90 W 22 V DC 2 V DC / 10 mA max. 180/360/600 W 24 V DC 22 V DC 2 V DC / 20 mA max. Type Temp. 40 C 50 C 60 C 70 C 1 ph 12 V / 6 A 6.0 5.7 5.4 4.5 180/360/600 W 48 V DC 44 V DC 4 V DC / 15 mA max. 1 ph 12 V / 12 A 12.0 9.5 7.0 3.7 0 & ( FN R K Y V U E L D W Q R L 1 ph 24 V / 3.8 A 3.8 3.1 2.5 1.7 Noise emission acc. to EN55022 Class B 1 ph 24 V / 7.5 A 7.5 6.3 5.0 3.3 Noise immunity tests acc. to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), 1 ph 24 V / 15 A 15.0 12.5 10.0 6.7 EN61000-4-4 (Burst), EN61000-4-5 (Surge), 1 ph 24 V / 25 A 25.0 22.5 20.0 13.3 EN610004-6 (conducted), EN61000-4-11 (Dips) 1 ph 36 V / 16.5 A 16.5 15.0 13.3 9.0 Limiting of mains voltage harmonic currents according to EN61000-3-2 1 ph 48 V / 2 A 2.0 1.6 1.3 0.8 Vibration IEC 60068-2-6 3 axes, Sinus, 1055 Hz, 1 g, 1 oct./min 1 ph 48 V / 4 A 4.0 3.3 2.5 1.7 Shock IEC 60068-2-27 3 axes, 15 g, half sinus, 11 ms 1 ph 48 V / 7.5 A 7.5 6.3 5.0 3.3 H O F ( W U F L O V D I D H W H S L G S D O V W U D G Q D G V 1 ph 48 V / 12.5 A 12.5 11.3 10.0 7.5 Electrical equipment of machines according to EN60204 1-2 ph 24 V / 7.5 A 7.5 6.3 5.0 3.3 Safety transformers for switched-mode power units according to EN61558-2-4 1-2 ph 24 V / 15 A 15.0 12.5 10.0 6.7 Machinery with electronic equipment according to EN50178 1-2 ph 24 V / 25 A 25.0 22.5 20.0 13.3 Safety extra low voltage SELV according to EN60950 CP T SNT... 100 100 90 90 600 W 80 80 70 70 90 W 70 W 60 60 180 W 140 W 360 W 50 50 40 40 85 90 100 110 115 132 187 230 264 -25 40 50 60 70 Temperature C Input Voltage V AC A.26 1460790000 2014/2015 Switch-mode power supplies Output Power % Pmax Output Power % Pmax + +connectPower PRO-H connectPower CP T SNT 70W 12V 6A CP T SNT 140W 12V 12A PRO-H A L (+) L (+) AC AC N () N () 13 13 Data Data 14 14 PE PE Link Link DC DC DC OK DC OK Technical data Input Rated input voltage 100...240 V AC (wide-range input) 100240 V AC (auto-select) Input voltage range AC 85...264 V AC 85132 V AC, 187264 V AC Frequency range AC 47...63 Hz 47...63 Hz AC current consumption 1 A 230 V AC, 2 A 115 V AC 1.4 A 230 V AC, 2.5 A 115 V AC Input fuse (internal) / Inrush current 4 A / < 20 A (230 V AC) 4 A / < 20 A (230 V AC) Recommended back-up fuse 616 A, char. B, circuit breaker 616 A, char. B, circuit breaker Output Rated output voltage 12 V DC 1 % 12 V DC 1 % Output voltage 12...14 V DC (adjustable via potentiometer on front) 12...14 V DC (adjustable via potentiometer on front) Residual ripple, breaking spikes 100 mV 12 V DC, I 100 mV 12 V DC, I SS nom SS nom Rated (nominal) output current U 6 A 40 C 12 A 40 C Nom Continous output current 24 V DC 6 A 40 C, 5.4 A 60 C, 4.5 A 70 C 12 A 40 C, 7 A 60 C, 3.7 A 70 C General data Degree of efficiency typ. 82 % 230 V AC typ. 85 % 230 V AC AC failure bridging time I min. 20 ms 230 V AC, min. 10 ms 115 V AC min. 20 ms 230 V AC, min. 10 ms 115 V AC Nom Parallel connection option yes, max. 5 yes, max. 5 Depth x width x height 110 / 35 / 110 mm 110 / 54 / 110 mm Weight 0.5 kg 0.7 kg Approvals Approvals BVATEX CE CSA cULus cURus GOSTME25 BVATEX CE CSA cULus cURus GOSTME25 Connection data Input Output Input Output Wire connection method Screw connection Screw connection Screw connection Screw connection Number of terminals 3 for L/N/PE 2 (+ / -) 3 for L/N/PE 7 (+ / - / Signal) Wire cross-section, rigid min/max mm 0.5 / 2.5 1 / 2.5 0.5 / 2.5 1 / 2.5 Wire cross-section, flexible min/max mm 0.5 / 2.5 1 / 2.5 0.5 / 2.5 1 / 2.5 Wire cross-section, AWG/kcmil min/max 24 / 12 18 / 12 24 / 12 18 / 12 Note Ordering data Type Qty. Order No. Type Qty. Order No. CP T SNT 70W 12V 6A 1 1105430000 CP T SNT 140W 12V 12A 1 1105440000 The internal varistor found in a switch-mode power supply does not replace the The internal varistor found in a switch-mode power supply does not replace the Note necessary surge protection in a system. necessary surge protection in a system. Accessories Note 1460790000 2014/2015 A.27 Switch-mode power supplies + + +