FCB100 Series AC-DC POWER SUPPLIES CONVECTION FAN 80W COOLED 100W COOLED The FCB100 is a series of open frame AC-DC power supplies designed for medical devices (including BF), industrial electronics, ITE & household applications. The FCB100 is compliant with class B conducted & radiated emissions, can be used in both class I & class II installations and the wide 80VAC to 264VAC operating input range makes it ideal for both home healthcare applications and in hospital use. With both convection and fan cooled ratings, extremely low emissions and safety & EMC certification for global use, the FCB100 benefits system designers with easy integration into a wide range of applications across multiple end markets Applications Features 80W convection cooled Household Industrial Medical Appliances Electronics 100W fan cooled 4 x 2 footprint, low 1.25 profile Class I & Class II applications Medical (BF), ITE & household approvals Class B conducted & radiated emissions Input Range 80 to 264VAC Dimensions <0.3W no load input power 4.00 x 2.00 x 1.25 (101.6 x 50.8 x 31.8mm) Regulated single outputs from 12 to 48VDC Short circuit, overvoltage & overload protection -25C to +70C operating temperature Models & Ratings Model Number Output Power Output Voltage Convection cooled (40C) Convection cooled (50C) Fan cooled (10cfm) FCB100US12 12.0VDC 7.5A 6.7A 8.3A FCB100US15 15.0VDC 6.0A 5.3A 6.7A FCB100US19 19.0VDC 4.7A 4.2A 5.3A 100W FCB100US24 24.0VDC 4.0A 3.5A 4.2A FCB100US36 36.0VDC 2.6A 2.4A 2.8A FCB100US48 48.0VDC 2.0A 1.8A 2.1AAC-DC POWER SUPPLIES FCB100 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 80 264 VAC Derate from 100% at 90VAC to 90% at 85VAC and 80% at 80VAC Input Frequency 47 63 Hz Input Current - Full Load 1.8/1.1 A rms 115/230VAC full load No Load Input Power 0.3 W Inrush Current 60 A At 264VAC, cold start 25C Earth Leakage Current 270 A Input Protection Internal T3.15A/300VAC fuse fitted in line and neutral Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 VDC Initial Set Accuracy 1.5 % At 50% load Minimum Load No minimum load required Line Regulation 0.5 % 90-264VAC Load Regulation 1 % Start Up Delay 2 s Start Up Rise Time 50/150 ms 0C/<-10C Overshoot 5 % Hold Up Time 8 14 ms At full load and 115/230VAC Deviation, recovery within 1% in less than 500s for a 25% Transient Response 4 % load change Ripple & Noise 1 % 0C to 70C Overvoltage Protection 110 150 %Vnom Recycle input to reset Overload Protection 110 175 % Short Circuit Protection Trip and restart (hiccup mode) Patient Leakage Current 95 A Overtemperature Protection Measured internally, recycle input to reset Temperature Coefficient 0.02 %/C General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 87 % Model dependant 4000 2 x MOPP Isolation: Input to Output Input to Ground 1500 VAC 1 x MOPP Output to Ground 1500 1 x MOPP Switching Frequency 22 70 kHz 3 Power Density 10 W/in Mean Time Between Failure 390 khrs MIL-HDBK-217F, 25C GB. Weight 0.35 (160) lb (g) 2